Changes for page 05. Data processing

Last modified by tabermah on 2024-12-11 11:17

From version 44.1
edited by tabermah
on 2024-12-09 13:48
Change comment: There is no comment for this version
To version 45.3
edited by tabermah
on 2024-12-11 11:17
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -2,7 +2,7 @@
2 2  
3 3  = 5.1. Automatic data processing =
4 4  
5 -Unless you un-check the option for the specific acquisition run, autoprocessing will be executed. For standard rotational data autoprocessing is via XDSAPP ([[https:~~/~~/www.helmholtz-berlin.de/forschung/oe/ps/macromolecular-crystallography/hzb-mx-software/xdsapp3/index_en.html>>url:https://www.helmholtz-berlin.de/forschung/oe/ps/macromolecular-crystallography/hzb-mx-software/xdsapp3/index_en.html||shape="rect"]], current version 3.1.9) (Sparta et al. (2016) //J. Apple. Cryst.// **49**, 1085-1092) for strategy calculation we use Mosflm (Leslie //Acta D//**62** (2006) 48-57) and Spotfinder ((% style="color:#000000; text-decoration:none" %)Zhang et al. (2006) (% style="text-align:left; text-decoration:none" %)//J. Appl. Cryst.//(% style="color:#000000; text-decoration:none" %) (% style="text-align:left; text-decoration:none" %)**39**(% style="color:#000000; text-decoration:none" %), 112–119)(%%) for producing the heatmap for the grid scans. The results are compiled into HTML-files to give you a convenient way of checking them. The output files are in the processed folders of the corresponding datasets.  A self refreshing index of all results is created in the beamtimes processed folder. During the beamtime you can open it from file::~/~//gpfs/current/processed/index.html in a browser. The HTML-file is also contained in your data backup.
5 +Unless you un-check the option for the specific acquisition run, autoprocessing will be executed. For standard rotational data autoprocessing is via XDSAPP ([[https:~~/~~/www.helmholtz-berlin.de/forschung/oe/ps/macromolecular-crystallography/hzb-mx-software/xdsapp3/index_en.html>>url:https://www.helmholtz-berlin.de/forschung/oe/ps/macromolecular-crystallography/hzb-mx-software/xdsapp3/index_en.html||shape="rect"]], current version 3.1.9) (Sparta et al. (2016) //J. Apple. Cryst.// **49**, 1085-1092) for strategy calculation we use Mosflm (Leslie //Acta D//**62** (2006) 48-57) and Spotfinder ((% style="color:#000000; text-decoration:none" %)Zhang et al. (2006) (% style="text-align:left; text-decoration:none" %)//J. Appl. Cryst.//(% style="color:#000000; text-decoration:none" %) (% style="text-align:left; text-decoration:none" %)**39**(% style="color:#000000; text-decoration:none" %), 112–119)(%%) for producing the heatmap for the grid scans. The results are compiled into HTML-files to give you a convenient way of checking them. The output files are in the processed folders of the corresponding datasets.  A self refreshing index of all results is created in the beamtimes processed folder. During the beamtime you can open it from [[file:~~/~~//gpfs/current/processed/index.html>>file:///gpfs/current/processed/index.html]] in a browser. The HTML-file is also contained in your data backup.
6 6  
7 7  = 5.2. Manual data processing =
8 8  
... ... @@ -114,7 +114,7 @@
114 114  Software packages might be available out-of-the box as system installs or as part from the OS default repository, others are available via module functionality. A description on how to enable/use a particular software package is given on [[confluence>>https://confluence.desy.de/display/IS/Software||shape="rect" style="text-decoration: none;"]].
115 115  
116 116  (% style="text-align: justify;" %)
117 -Crystallographic software packages are in the [[Photon Science section>>https://confluence.desy.de/display/MXW/Photon+Science||shape="rect"]].
117 +Crystallographic software packages are listed in the [[Photon Science and Structural Biology tabs>>https://docs.desy.de/maxwell/applications/||shape="rect"]].
118 118  
119 119  (% style="text-align: justify;" %)
120 120  You can store analysis results in scratch_cc (temporary/testing results) or processed (final results).