Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -65,8 +65,16 @@ 65 65 **14.3 Connecting sample to ElveFlow, sample exchange 66 66 ** 67 67 68 - [[image:attach:20211201_095033.jpg||thumbnail="true"height="250"]][[image:attach:20211201_095205.jpg||height="250"]][[image:attach:20211201_095232.jpg||height="250"]]68 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bttom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 69 69 70 +Be aware to which channel and nozzle line your sample is connected. 71 + 72 +Red → Channel 1, crystal line (nozzle capillary without marks) 73 + 74 +Green → Channel 2, substrate line (nozzle capillary is marked in black) 75 + 76 +[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 77 + 70 70 \\ 71 71 72 72 \\ ... ... @@ -74,22 +74,82 @@ 74 74 **14.4 TapeDrive operation 75 75 ** 76 76 77 -The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open ,shortly after a small window.85 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 78 78 Now start the client. Same thing, a terminal will open, shortly after a small window. 87 + 88 +Click 'Devices' in the **client session** to open the control window. 79 79 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 80 80 81 81 * **Tape:** 82 82 ** Click on the 'main tape' icon 83 -** Change the velocity by typing anything from 0.3-3.0 mm/s 93 +** Change the velocity by typing anything from **0.3-3.0 mm/s** 84 84 ** Common velocity is 1.0-1.5 mm/s 95 +** kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 96 +\\ 85 85 ** [[image:attach:kamzik_tape.PNG||height="400"]] 86 86 87 87 \\ 88 88 101 +* **Sample nozzle:** 102 +** Click an the 'nozzle' icon. 103 +** ((( 104 +The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 105 +The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 106 +\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 107 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 108 + 109 +(% class="wrapped" %) 110 +|=((( 89 89 \\ 112 +)))|=((( 113 +direction 114 +)))|=((( 115 +recommended step size 116 +for visual adjustment 117 +)))|=(% colspan="1" %)((( 118 +recommended step size 119 +during data collection 120 +))) 121 +|((( 122 ++x 123 +)))|((( 124 +away from X-ray interaction point 125 +)))|((( 126 +1.0 - 0.5 mm 127 +)))|(% colspan="1" %)((( 128 +0.1 - 0.2 mm 129 +))) 130 +|((( 131 ++y 132 +)))|((( 133 +up 134 +)))|((( 135 +1.0 - 0.5 mm 136 +)))|(% colspan="1" %)((( 137 +0.1 - 0.2 mm 138 +))) 139 +|((( 140 ++z 141 +)))|((( 142 +towards detector tower, away from tape 143 +)))|((( 144 +0.5 - 0.2 mm 145 +)))|(% colspan="1" %)((( 146 +0.1 - 0.2 mm 147 +be careful with -z, tape could be pushed out of focus 148 +))) 90 90 150 +** 151 +\\** 152 +))) 153 +** [[image:attach:kamzik_nozzle.PNG||height="400"]] 154 + 91 91 \\ 92 92 157 +\\ 158 + 159 +\\ 160 + 93 93 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 94 94 95 95 xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 ... ... @@ -102,8 +102,17 @@ 102 102 103 103 **14.5 Tape roll exchange** 104 104 105 - **[[image:attach:20211201_094111.jpg||height="250"]][[image:attach:20211201_094101.jpg||height="250"]]**173 +The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 106 106 175 +* Remove the (almost) empty feeder roll by pulling it upwards. 176 +* Cut the tape with some cm overlap to glue to the new roll. 177 +* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 178 +* Cut the first cm of the new tape roll, directly before the black sticky part. 179 +* Use this sticky part to attach the end of the old 180 + 181 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 182 +** 183 + 107 107 \\ 108 108 109 109 \\
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23503 75251 +235039450 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23503 7525/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/235039450/14. Serial Crystallography: CFEL TapeDrive