Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,20 @@ 1 -[[image:attach:TapeDrive_beschriftet.PNG||height="400"]][[image:attach:TapeDrive scheme.png||height="400"]] 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 2 2 3 -**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** 4 4 6 +{{toc/}} 7 + 8 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]] 9 + 10 +\\ 11 + 12 +\\ 13 + 14 +\\ 15 + 16 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1RevertfromCrystallographytoTapeDrive(P11staff/CFEL)"/}}**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** === 17 + 5 5 * remove vortex 6 6 * beamstop to out-position? 7 7 * remove goniometer. The airbearing should be stopped (p11/servermotor/eh.1.01) ... ... @@ -50,7 +50,7 @@ 50 50 51 51 \\ 52 52 53 -**14.2 Sample characteristics and preparation** 66 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2Samplecharacteristicsandpreparation"/}}**14.2 Sample characteristics and preparation** === 54 54 55 55 suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 56 56 ... ... @@ -62,34 +62,114 @@ 62 62 63 63 \\ 64 64 65 -**14.3 Connecting sample to ElveFlow, sample exchange 66 -** 78 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3ConnectingsampletoElveFlow,sampleexchange"/}}**14.3 Connecting sample to ElveFlow, sample exchange 79 +** === 67 67 68 - [[image:attach:20211201_095033.jpg||thumbnail="true"height="250"]][[image:attach:20211201_095205.jpg||height="250"]][[image:attach:20211201_095232.jpg||height="250"]]81 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 69 69 70 - \\83 +Be aware to which channel and nozzle line your sample is connected. 71 71 85 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) 86 + 87 + Green → Channel 2, substrate line (nozzle capillary is marked in black) 88 + 89 +[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 90 + 91 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O. 92 + 93 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 94 + 72 72 \\ 73 73 74 -**14.4 TapeDrive operation 75 -** 97 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation 98 +** === 76 76 77 -The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open ,shortly after a small window.100 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 78 78 Now start the client. Same thing, a terminal will open, shortly after a small window. 102 + 103 +Click 'Devices' in the **client session** to open the control window. 79 79 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 80 80 81 -* **Tape:** 82 -** Click on the 'main tape' icon 83 -** Change the velocity by typing anything from 0.3-3.0 mm/s 84 -** Common velocity is 1.0-1.5 mm/s 85 -** [[image:attach:kamzik_tape.PNG||height="400"]] 106 +**Tape** 86 86 108 +* Click on the 'main tape' icon 109 +* Change the velocity by typing anything from **0.3-3.0 mm/s** 110 +* Common velocity is 1.0-1.5 mm/s 111 +* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 87 87 \\ 113 +* [[image:attach:kamzik_tape.PNG||height="400"]] 88 88 115 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 116 + 117 +* Click an the 'nozzle' icon. 118 +* ((( 119 +The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 120 +The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 121 + 122 + 123 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 124 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 125 + 126 +(% class="wrapped" %) 127 +|=((( 89 89 \\ 129 +)))|=((( 130 +direction 131 +)))|=((( 132 +recommended step size 133 +for visual adjustment 134 +)))|=(% colspan="1" %)((( 135 +recommended step size 136 +during data collection 137 +))) 138 +|((( 139 ++x 140 +)))|((( 141 +away from X-ray interaction point 142 +)))|((( 143 +1.0 - 0.5 mm 144 +)))|(% colspan="1" %)((( 145 +0.1 - 0.2 mm 146 +))) 147 +|((( 148 ++y 149 +)))|((( 150 +up 151 +)))|((( 152 +1.0 - 0.5 mm 153 +)))|(% colspan="1" %)((( 154 +0.1 - 0.2 mm 155 +))) 156 +|((( 157 ++z 158 +)))|((( 159 +towards detector tower, away from tape 160 +)))|((( 161 +0.5 - 0.2 mm 162 +)))|(% colspan="1" %)((( 163 +0.1 - 0.2 mm 164 +be careful with -z, tape could be pushed out of focus 165 +))) 90 90 167 +** 168 +\\** 169 +))) 170 +* [[image:attach:kamzik_nozzle.PNG||height="400"]] 171 + 172 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 173 + 174 +* The chiller circulates fluid through the gas nozzle. 175 + 91 91 \\ 92 92 178 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 179 + 180 +\\ 181 + 182 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 183 + 184 +\\ 185 + 93 93 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 94 94 95 95 xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 ... ... @@ -100,16 +100,168 @@ 100 100 101 101 \\ 102 102 103 -**14.5 Tape roll exchange** 196 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** === 104 104 105 - **[[image:attach:20211201_094111.jpg||height="250"]][[image:attach:20211201_094101.jpg||height="250"]]**198 +The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 106 106 200 +* Remove the (almost) empty feeder roll by pulling it upwards. 201 +* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 202 +* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 203 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 204 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 205 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 206 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 207 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 208 +* Attach new tape to the empty roll by using some sticky tape. 209 +* Close tape stabilizer. 210 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 211 + 212 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 213 +** 214 + 107 107 \\ 108 108 109 109 \\ 110 110 219 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 220 + 111 111 \\ 112 112 223 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** === 224 + 225 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 226 + 227 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 228 + password: //written on control laptop (changes every 6 months)// 229 + 230 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 231 + 113 113 \\ 114 114 234 +**Check list:** 235 + 236 +* Open BS1 (//CrystalControl)// 237 +* Put collimator in (//CrystalControl)// 238 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 239 +* Open fast shutter (//CrystalControl)// 240 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 241 +* Close fast shutter (//CrystalControl)// 242 + 115 115 \\ 244 + 245 +**Start run in kamzik 246 +** 247 + 248 +Click "Start" icon in kamzik. 249 + 250 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 251 + 252 +---- 253 +{{/layout-cell}} 254 +{{/layout-section}} 255 + 256 +{{layout-section ac:type="two_equal"}} 257 +{{layout-cell}} 258 +(% class="task-list" %) 259 +((( 260 +{{task reference="/Tasks/Task_16" status="InProgress"}} 261 +Set your desired No. of frames 262 +{{/task}} 263 + 264 +{{task reference="/Tasks/Task_17" status="InProgress"}} 265 +Match exposure time with chopper setting 266 +{{/task}} 267 + 268 +{{task reference="/Tasks/Task_18" status="InProgress"}} 269 +Check trigger setting and match to chopper setting 270 +{{/task}} 271 + 272 +{{task reference="/Tasks/Task_19" status="InProgress"}} 273 +Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 274 +{{/task}} 275 + 276 +{{task reference="/Tasks/Task_20" status="InProgress"}} 277 +To start the run, click "<Call>" next to //exposure time// 278 +{{/task}} 279 +))) 280 +{{/layout-cell}} 281 + 282 +{{layout-cell}} 283 +|=((( 284 +Parameter 285 +)))|=((( 286 +explanation 287 +)))|=(% colspan="1" %)((( 288 +value 289 +))) 290 +|((( 291 +Images number 292 +)))|((( 293 +Set number of frames you want to collect 294 +)))|(% colspan="1" %)((( 295 +usually 100k - 200k, but adjust according to hitrate 296 + 297 +orientation: 10 % hitrate needs at least 100k images 298 +))) 299 +|((( 300 +exposure 301 +)))|((( 302 +exposure time of Eiger 303 + 304 +\\ 305 +)))|(% colspan="1" %)((( 306 +chopper at 133 Hz → 3.7 ms 307 + 308 +chopper at 66 Hz → 7.7 ms 309 + 310 +no chopper → 7.7 ms 311 + 312 +---- 313 +))) 314 +|((( 315 +run id 316 +)))|((( 317 +changes automatically 318 +)))|(% colspan="1" %)((( 319 +\\ 320 +))) 321 +|(% colspan="1" %)((( 322 +Detector distance 323 +)))|(% colspan="1" %)((( 324 +current detector postion readout 325 +)))|(% colspan="1" %)((( 326 +\\ 327 +))) 328 +|(% colspan="1" %)((( 329 +move_detector (distance) 330 +)))|(% colspan="1" %)((( 331 +Set detector distance 332 +)))|(% colspan="1" %)((( 333 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 334 +))) 335 +|(% colspan="1" %)((( 336 +Diode voltage 337 +)))|(% colspan="1" %)((( 338 +read out of diode 339 +)))|(% colspan="1" %)((( 340 +**~~ 0 !!! higher values indicate missaligned beam stop!!!** 341 +))) 342 +{{/layout-cell}} 343 +{{/layout-section}} 344 + 345 +{{layout-section ac:type="single"}} 346 +{{layout-cell}} 347 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 348 + 349 +* ((( 350 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 351 +))) 352 +* ((( 353 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 354 +))) 355 +* ((( 356 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 357 +))) 358 +{{/layout-cell}} 359 +{{/layout-section}} 360 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23 50375251 +236824566 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23 5037525/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824566/14. Serial Crystallography: CFEL TapeDrive