Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,16 @@ 1 -[[image:attach:TapeDrive_beschriftet.PNG||height="400"]][[image:attach:TapeDrive scheme.png||height="400"]] 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 4 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]] 2 2 3 - **14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)**6 +\\ 4 4 8 +\\ 9 + 10 +\\ 11 + 12 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1RevertfromCrystallographytoTapeDrive(P11staff/CFEL)"/}}**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** === 13 + 5 5 * remove vortex 6 6 * beamstop to out-position? 7 7 * remove goniometer. The airbearing should be stopped (p11/servermotor/eh.1.01) ... ... @@ -50,7 +50,7 @@ 50 50 51 51 \\ 52 52 53 -**14.2 Sample characteristics and preparation** 62 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2Samplecharacteristicsandpreparation"/}}**14.2 Sample characteristics and preparation** === 54 54 55 55 suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 56 56 ... ... @@ -62,36 +62,113 @@ 62 62 63 63 \\ 64 64 65 -**14.3 Connecting sample to ElveFlow, sample exchange 66 -** 74 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3ConnectingsampletoElveFlow,sampleexchange"/}}**14.3 Connecting sample to ElveFlow, sample exchange 75 +** === 67 67 68 - [[image:attach:20211201_095033.jpg||thumbnail="true"height="250"]][[image:attach:20211201_095205.jpg||height="250"]][[image:attach:20211201_095232.jpg||height="250"]]77 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 69 69 70 - \\79 +Be aware to which channel and nozzle line your sample is connected. 71 71 81 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) 82 + 83 + Green → Channel 2, substrate line (nozzle capillary is marked in black) 84 + 85 +[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 86 + 87 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O. 88 + 89 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 90 + 72 72 \\ 73 73 74 -**14.4 TapeDrive operation 75 -** 93 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation 94 +** === 76 76 77 -The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open ,shortly after a small window.96 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 78 78 Now start the client. Same thing, a terminal will open, shortly after a small window. 79 79 80 80 Click 'Devices' in the **client session** to open the control window. 81 81 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 82 82 83 -* **Tape:** 84 -** Click on the 'main tape' icon 85 -** Change the velocity by typing anything from 0.3-3.0 mm/s 86 -** Common velocity is 1.0-1.5 mm/s 87 -** [[image:attach:kamzik_tape.PNG||height="400"]] 102 +**Tape** 88 88 104 +* Click on the 'main tape' icon 105 +* Change the velocity by typing anything from **0.3-3.0 mm/s** 106 +* Common velocity is 1.0-1.5 mm/s 107 +* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 89 89 \\ 109 +* [[image:attach:kamzik_tape.PNG||height="400"]] 90 90 111 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 112 + 113 +* Click an the 'nozzle' icon. 114 +* ((( 115 +The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 116 +The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 117 + 118 + 119 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 120 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 121 + 122 +|=((( 91 91 \\ 124 +)))|=((( 125 +direction 126 +)))|=((( 127 +recommended step size 128 +for visual adjustment 129 +)))|=(% colspan="1" %)((( 130 +recommended step size 131 +during data collection 132 +))) 133 +|((( 134 ++x 135 +)))|((( 136 +away from X-ray interaction point 137 +)))|((( 138 +1.0 - 0.5 mm 139 +)))|(% colspan="1" %)((( 140 +0.1 - 0.2 mm 141 +))) 142 +|((( 143 ++y 144 +)))|((( 145 +up 146 +)))|((( 147 +1.0 - 0.5 mm 148 +)))|(% colspan="1" %)((( 149 +0.1 - 0.2 mm 150 +))) 151 +|((( 152 ++z 153 +)))|((( 154 +towards detector tower, away from tape 155 +)))|((( 156 +0.5 - 0.2 mm 157 +)))|(% colspan="1" %)((( 158 +0.1 - 0.2 mm 159 +be careful with -z, tape could be pushed out of focus 160 +))) 92 92 162 +** 163 +\\** 164 +))) 165 +* [[image:attach:kamzik_nozzle.PNG||height="400"]] 166 + 167 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 168 + 169 +* The chiller circulates fluid through the gas nozzle. 170 + 93 93 \\ 94 94 173 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 174 + 175 +\\ 176 + 177 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 178 + 179 +\\ 180 + 95 95 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 96 96 97 97 xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 ... ... @@ -102,16 +102,235 @@ 102 102 103 103 \\ 104 104 105 -**14.5 Tape roll exchange** 191 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** === 106 106 107 - **[[image:attach:20211201_094111.jpg||height="250"]][[image:attach:20211201_094101.jpg||height="250"]]**193 +The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 108 108 195 +* Remove the (almost) empty feeder roll by pulling it upwards. 196 +* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 197 +* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 198 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 199 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 200 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 201 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 202 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 203 +* Attach new tape to the empty roll by using some sticky tape. 204 +* Close tape stabilizer. 205 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 206 + 207 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 208 +** 209 + 109 109 \\ 110 110 111 111 \\ 112 112 214 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 215 +{{/layout-cell}} 216 +{{/layout-section}} 217 + 218 +{{layout-section ac:type="single"}} 219 +{{layout-cell}} 220 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Chopper"/}}**14.7 Chopper** === 221 + 222 +start chopper gui from terminal: 223 + 224 +(% class="code" %) 225 +((( 226 + cd /gpfs/local/shared/ChopperControl 227 +))) 228 + 229 +(% class="code" %) 230 +((( 231 + python chopperControl.py 232 +))) 233 +{{/layout-cell}} 234 +{{/layout-section}} 235 + 236 +{{layout-section ac:type="two_equal"}} 237 +{{layout-cell}} 238 + [[image:attach:20211212_233140.jpg||height="250"]] 239 +{{/layout-cell}} 240 + 241 +{{layout-cell}} 242 +**Chopper → no Chopper** 243 + 244 +* decrease frequency by max. 10 Hz steps\\ 245 +** click arrow down 10x, "Set", arrow down 10x, "Set", .... 246 +* at frequency = 10 Hz, click "Stop" 247 +* set "Hole" to <none> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 248 + 249 +(% style="color: rgb(0,0,0);" %)**no Chopper → Chopper** 250 + 251 +* (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 252 +* (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 253 +** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 254 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 255 +{{/layout-cell}} 256 +{{/layout-section}} 257 + 258 +{{layout-section ac:type="single"}} 259 +{{layout-cell}} 260 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Datacollection"/}}**14.8 Data collection** === 261 + 262 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 263 + 264 +(% class="code" %) 265 +((( 266 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 267 + password: written on control laptop (changes every 6 months) 268 +))) 269 + 270 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 271 + 113 113 \\ 114 114 274 +Click "Start" icon in kamzik. 275 + 276 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 277 + 278 +---- 279 +{{/layout-cell}} 280 +{{/layout-section}} 281 + 282 +{{layout-section ac:type="two_equal"}} 283 +{{layout-cell}} 284 +**Check list:** 285 + 286 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 287 + 288 +* Open BS1 (//CrystalControl)// 289 +* Put collimator in (//CrystalControl)// 290 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 291 +* Open fast shutter (//CrystalControl)// 292 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 293 +* Close fast shutter (//CrystalControl)// 294 + 115 115 \\ 116 116 297 +**Set run parameters and go 🏃💥** 298 + 299 +1. Set your desired No. of frames 300 +1. Match exposure time with chopper setting 301 +1. Check trigger setting and match to chopper setting 302 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 303 +1. To start the run, click "<Call>" next to //exposure time// 304 + 117 117 \\ 306 + 307 +(% style="color: rgb(153,51,102);" %)**//Current bug~://** 308 + 309 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 310 + 311 + 312 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 313 + 314 +(% class="code" %) 315 +((( 316 + cd /gpfs/current/raw/scan_frames 317 + watch "ls -lrt <run number>/ | tail" 318 +\\\\\\\\ 319 +))) 320 +{{/layout-cell}} 321 + 322 +{{layout-cell}} 323 +(% class="wrapped relative-table" style="width: 100.0%;" %) 324 +|=((( 325 +Parameter 326 +)))|=((( 327 +explanation 328 +)))|=(% colspan="1" %)((( 329 +value 330 +))) 331 +|((( 332 +Images number 333 +)))|((( 334 +Set number of frames you want to collect 335 +)))|(% colspan="1" %)((( 336 +usually 100k - 200k, but adjust according to hitrate 337 + 338 +orientation: 10 % hitrate needs at least 100k images 339 +))) 340 +|((( 341 +exposure 342 +)))|((( 343 +exposure time of Eiger 344 + 345 +\\ 346 +)))|(% colspan="1" %)((( 347 +chopper at 133 Hz → 3.7 ms 348 + 349 +chopper at 66 Hz → 7.7 ms 350 + 351 +no chopper → 7.7 ms 352 + 353 +---- 354 +))) 355 +|((( 356 +run id 357 +)))|((( 358 +changes automatically 359 +)))|(% colspan="1" %)((( 360 +\\ 361 +))) 362 +|(% colspan="1" %)((( 363 +Detector distance 364 +)))|(% colspan="1" %)((( 365 +current detector postion readout 366 +)))|(% colspan="1" %)((( 367 +\\ 368 +))) 369 +|(% colspan="1" %)((( 370 +move_detector (distance) 371 +)))|(% colspan="1" %)((( 372 +Set detector distance 373 +)))|(% colspan="1" %)((( 374 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 375 +))) 376 +|(% colspan="1" %)((( 377 +Diode voltage 378 +)))|(% colspan="1" %)((( 379 +read out of diode 380 +)))|(% colspan="1" %)((( 381 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 382 +Call local contact 383 +** 384 +))) 385 +{{/layout-cell}} 386 +{{/layout-section}} 387 + 388 +{{layout-section ac:type="single"}} 389 +{{layout-cell}} 390 +---- 391 + 392 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.9Troubleshooting"/}}14.9 Troubleshooting === 393 + 394 +* ((( 395 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 396 + 397 +* Tape roll empty? 398 +* motor connected (icon green)? 399 +))) 400 + 401 +\\ 402 + 403 +* ((( 404 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 405 + 406 +* displayed in green=connected? 407 +* nozzle holder colliding somewhere? 408 +* motor limits reached? → position displayed in red 409 +))) 410 + 411 +\\ 412 + 413 +* ((( 414 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 415 + 416 +* channel turned on? 417 +* Sample empty? 418 +* Nozzle or lines clogged? → flush with water, change nozzle 419 +))) 420 +{{/layout-cell}} 421 +{{/layout-section}} 422 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -235 0377091 +236824590 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/235 037709/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824590/14. Serial Crystallography: CFEL TapeDrive