Last modified by chatzies on 2025-11-27 11:35

From version 17.1
edited by ahenkel
on 2021-12-02 14:15
Change comment: There is no comment for this version
To version 40.1
edited by ahenkel
on 2021-12-12 23:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,20 @@
1 -[[image:attach:TapeDrive_beschriftet.PNG||height="400"]][[image:attach:TapeDrive scheme.png||height="400"]]
1 +{{layout}}
2 +{{layout-section ac:type="single"}}
3 +{{layout-cell}}
2 2  
3 -**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)**
4 4  
6 +{{toc/}}
7 +
8 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]]
9 +
10 +\\
11 +
12 +\\
13 +
14 +\\
15 +
16 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1RevertfromCrystallographytoTapeDrive(P11staff/CFEL)"/}}**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** ===
17 +
5 5  * remove vortex
6 6  * beamstop to out-position?
7 7  * remove goniometer. The airbearing should be stopped (p11/servermotor/eh.1.01)
... ... @@ -50,7 +50,7 @@
50 50  
51 51  \\
52 52  
53 -**14.2 Sample characteristics and preparation**
66 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2Samplecharacteristicsandpreparation"/}}**14.2 Sample characteristics and preparation** ===
54 54  
55 55  suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.
56 56  
... ... @@ -62,42 +62,55 @@
62 62  
63 63  \\
64 64  
65 -**14.3 Connecting sample to ElveFlow, sample exchange
66 -**
78 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3ConnectingsampletoElveFlow,sampleexchange"/}}**14.3 Connecting sample to ElveFlow, sample exchange
79 +** ===
67 67  
68 -[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]][[image:attach:20211201_095205.jpg||height="250"]][[image:attach:20211201_095232.jpg||height="250"]]
81 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!**
69 69  
70 -\\
83 +Be aware to which channel and nozzle line your sample is connected.
71 71  
85 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks)
86 +
87 + Green → Channel 2, substrate line (nozzle capillary is marked in black)
88 +
89 +[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]]
90 +
91 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O.
92 +
93 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]]
94 +
72 72  \\
73 73  
74 -**14.4 TapeDrive operation
75 -**
97 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation
98 +** ===
76 76  
77 -The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open, shortly after a small window.
100 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window.
78 78  Now start the client. Same thing, a terminal will open, shortly after a small window.
79 79  
80 80  Click 'Devices' in the **client session** to open the control window.
81 81  [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]]
82 82  
83 -* **Tape:**
84 -** Click on the 'main tape' icon
85 -** Change the velocity by typing anything from 0.3-3.0 mm/s
86 -** Common velocity is 1.0-1.5 mm/s
87 -** kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point.
88 -** [[image:attach:kamzik_tape.PNG||height="400"]]
106 +**Tape**
89 89  
108 +* Click on the 'main tape' icon
109 +* Change the velocity by typing anything from **0.3-3.0 mm/s**
110 +* Common velocity is 1.0-1.5 mm/s
111 +* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point.
90 90  \\
113 +* [[image:attach:kamzik_tape.PNG||height="400"]]
91 91  
92 -* **Sample nozzle:**
93 -** Click an the 'nozzle' icon.
94 -** (((
95 -The nozzle position can be adjusted in xyz by clicking on the arrows up and down. Step size can be varied, 1mm steps are rather big and should be used carefully, for y-movement always use a stepsize <= 0.5mm.
115 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ====
116 +
117 +* Click an the 'nozzle' icon.
118 +* (((
119 +The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully.
96 96  The absolute position is **not calibrated** and therefore changes after each restart of kamzik.
97 -+x    right, away from X-ray interaction point
98 -+y    up
99 -+z    towards detector tower, away from the tape
100 100  
122 +
123 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%)
124 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments.
125 +
126 +(% class="wrapped" %)
101 101  |=(((
102 102  \\
103 103  )))|=(((
... ... @@ -112,7 +112,7 @@
112 112  |(((
113 113  +x
114 114  )))|(((
115 -right, away from X-ray interaction point
141 +away from X-ray interaction point
116 116  )))|(((
117 117  1.0 - 0.5 mm
118 118  )))|(% colspan="1" %)(((
... ... @@ -138,15 +138,23 @@
138 138  be careful with -z, tape could be pushed out of focus
139 139  )))
140 140  
141 -(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%)**
167 +**
142 142  \\**
143 143  )))
144 -** [[image:attach:kamzik_nozzle.PNG||height="400"]]
170 +* [[image:attach:kamzik_nozzle.PNG||height="400"]]
145 145  
172 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ====
173 +
174 +* The chiller circulates fluid through the gas nozzle.
175 +
146 146  \\
147 147  
178 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ====
179 +
148 148  \\
149 149  
182 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ====
183 +
150 150  \\
151 151  
152 152  Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
... ... @@ -159,16 +159,173 @@
159 159  
160 160  \\
161 161  
162 -**14.5 Tape roll exchange**
196 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** ===
163 163  
164 -**[[image:attach:20211201_094111.jpg||height="250"]][[image:attach:20211201_094101.jpg||height="250"]]**
198 +The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s).
165 165  
200 +* Remove the (almost) empty feeder roll by pulling it upwards.
201 +* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!**
202 +* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm**
203 +* Cut the first cm of the new tape roll, directly behind the black sticky part.
204 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll.
205 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!//
206 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s).
207 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded.
208 +* Attach new tape to the empty roll by using some sticky tape.
209 +* Close tape stabilizer.
210 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape".
211 +
212 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]]
213 +**
214 +
166 166  \\
167 167  
168 168  \\
169 169  
219 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** ===
220 +
170 170  \\
171 171  
223 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** ===
224 +
225 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
226 +
227 +(% class="code" %)
228 +(((
229 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611
230 + password: written on control laptop (changes every 6 months)
231 +)))
232 +
233 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password//
234 +
172 172  \\
173 173  
237 +Click "Start" icon in kamzik.
238 +
239 +[[image:attach:kamzik_run-tile.jpg||height="400"]]
240 +
241 +----
242 +{{/layout-cell}}
243 +{{/layout-section}}
244 +
245 +{{layout-section ac:type="two_equal"}}
246 +{{layout-cell}}
247 +**Check list:**
248 +
249 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!//
250 +
251 +* Open BS1  (//CrystalControl)//
252 +* Put collimator in (//CrystalControl)//
253 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)//
254 +* Open fast shutter (//CrystalControl)//
255 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)//
256 +* Close fast shutter (//CrystalControl)//
257 +
174 174  \\
259 +
260 +**Set run parameters and go 🏃💥**
261 +
262 +1. Set your desired No. of frames
263 +1. Match exposure time with chopper setting
264 +1. Check trigger setting and match to chopper setting
265 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it.
266 +1. To start the run, click "<Call>" next to //exposure time//
267 +
268 +\\
269 +
270 +(% style="color: rgb(153,51,102);" %)**//Current bug~://**
271 +
272 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>".
273 +
274 +
275 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with:
276 +
277 +(% class="code" %)
278 +(((
279 + cd /gpfs/current/raw/scan_frames
280 + watch "ls -lrt <run number>/ | tail"
281 +)))
282 +{{/layout-cell}}
283 +
284 +{{layout-cell}}
285 +(% class="wrapped relative-table" style="width: 100.0%;" %)
286 +|=(((
287 +Parameter
288 +)))|=(((
289 +explanation
290 +)))|=(% colspan="1" %)(((
291 +value
292 +)))
293 +|(((
294 +Images number
295 +)))|(((
296 +Set number of frames you want to collect
297 +)))|(% colspan="1" %)(((
298 +usually 100k - 200k, but adjust according to hitrate
299 +
300 +orientation: 10 % hitrate needs at least 100k images
301 +)))
302 +|(((
303 +exposure
304 +)))|(((
305 +exposure time of Eiger
306 +
307 +\\
308 +)))|(% colspan="1" %)(((
309 +chopper at 133 Hz → 3.7 ms
310 +
311 +chopper at 66 Hz   → 7.7 ms
312 +
313 +no chopper            → 7.7 ms
314 +
315 +----
316 +)))
317 +|(((
318 +run id
319 +)))|(((
320 +changes automatically
321 +)))|(% colspan="1" %)(((
322 +\\
323 +)))
324 +|(% colspan="1" %)(((
325 +Detector distance
326 +)))|(% colspan="1" %)(((
327 +current detector postion readout
328 +)))|(% colspan="1" %)(((
329 +\\
330 +)))
331 +|(% colspan="1" %)(((
332 +move_detector (distance)
333 +)))|(% colspan="1" %)(((
334 +Set detector distance
335 +)))|(% colspan="1" %)(((
336 +200.0 mm   (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>"
337 +)))
338 +|(% colspan="1" %)(((
339 +Diode voltage
340 +)))|(% colspan="1" %)(((
341 +read out of diode
342 +)))|(% colspan="1" %)(((
343 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 
344 +Call local contact
345 +**
346 +)))
347 +{{/layout-cell}}
348 +{{/layout-section}}
349 +
350 +{{layout-section ac:type="single"}}
351 +{{layout-cell}}
352 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting ===
353 +
354 +* (((
355 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ====
356 +)))
357 +* (((
358 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ====
359 +)))
360 +* (((
361 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ====
362 +)))
363 +{{/layout-cell}}
364 +{{/layout-section}}
365 +{{/layout}}
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -235037729
1 +236824574
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/11/pages/235037729/14. Serial Crystallography: CFEL TapeDrive
1 +https://confluence.desy.de/spaces/11/pages/236824574/14. Serial Crystallography: CFEL TapeDrive