Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,20 @@ 1 -[[image:attach:TapeDrive_beschriftet.PNG||height="400"]][[image:attach:TapeDrive scheme.png||height="400"]] 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 2 2 3 -**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** 4 4 6 +{{toc/}} 7 + 8 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]] 9 + 10 +\\ 11 + 12 +\\ 13 + 14 +\\ 15 + 16 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1RevertfromCrystallographytoTapeDrive(P11staff/CFEL)"/}}**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** === 17 + 5 5 * remove vortex 6 6 * beamstop to out-position? 7 7 * remove goniometer. The airbearing should be stopped (p11/servermotor/eh.1.01) ... ... @@ -50,7 +50,7 @@ 50 50 51 51 \\ 52 52 53 -**14.2 Sample characteristics and preparation** 66 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2Samplecharacteristicsandpreparation"/}}**14.2 Sample characteristics and preparation** === 54 54 55 55 suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 56 56 ... ... @@ -62,42 +62,55 @@ 62 62 63 63 \\ 64 64 65 -**14.3 Connecting sample to ElveFlow, sample exchange 66 -** 78 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3ConnectingsampletoElveFlow,sampleexchange"/}}**14.3 Connecting sample to ElveFlow, sample exchange 79 +** === 67 67 68 - [[image:attach:20211201_095033.jpg||thumbnail="true"height="250"]][[image:attach:20211201_095205.jpg||height="250"]][[image:attach:20211201_095232.jpg||height="250"]]81 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 69 69 70 - \\83 +Be aware to which channel and nozzle line your sample is connected. 71 71 85 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) 86 + 87 + Green → Channel 2, substrate line (nozzle capillary is marked in black) 88 + 89 +[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 90 + 91 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O. 92 + 93 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 94 + 72 72 \\ 73 73 74 -**14.4 TapeDrive operation 75 -** 97 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation 98 +** === 76 76 77 -The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open ,shortly after a small window.100 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 78 78 Now start the client. Same thing, a terminal will open, shortly after a small window. 79 79 80 80 Click 'Devices' in the **client session** to open the control window. 81 81 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 82 82 83 -* **Tape:** 84 -** Click on the 'main tape' icon 85 -** Change the velocity by typing anything from 0.3-3.0 mm/s 86 -** Common velocity is 1.0-1.5 mm/s 87 -** kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 88 -** [[image:attach:kamzik_tape.PNG||height="400"]] 106 +**Tape** 89 89 108 +* Click on the 'main tape' icon 109 +* Change the velocity by typing anything from **0.3-3.0 mm/s** 110 +* Common velocity is 1.0-1.5 mm/s 111 +* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 90 90 \\ 113 +* [[image:attach:kamzik_tape.PNG||height="400"]] 91 91 92 -* **Sample nozzle:** 93 -** Click an the 'nozzle' icon. 94 -** ((( 95 -The nozzle position can be adjusted in xyz by clicking on the arrows up and down. Step size can be varied, 1mm steps are rather big and should be used carefully, for y-movement always use a stepsize <= 0.5mm. 115 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 116 + 117 +* Click an the 'nozzle' icon. 118 +* ((( 119 +The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 96 96 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 97 -+x right, away from X-ray interaction point 98 -+y up 99 -+z towards detector tower, away from the tape 100 100 122 + 123 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 124 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 125 + 126 +(% class="wrapped" %) 101 101 |=((( 102 102 \\ 103 103 )))|=((( ... ... @@ -112,7 +112,7 @@ 112 112 |((( 113 113 +x 114 114 )))|((( 115 - right,away from X-ray interaction point141 +away from X-ray interaction point 116 116 )))|((( 117 117 1.0 - 0.5 mm 118 118 )))|(% colspan="1" %)((( ... ... @@ -138,15 +138,23 @@ 138 138 be careful with -z, tape could be pushed out of focus 139 139 ))) 140 140 141 - (% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%)**167 +** 142 142 \\** 143 143 ))) 144 -* *[[image:attach:kamzik_nozzle.PNG||height="400"]]170 +* [[image:attach:kamzik_nozzle.PNG||height="400"]] 145 145 172 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 173 + 174 +* The chiller circulates fluid through the gas nozzle. 175 + 146 146 \\ 147 147 178 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 179 + 148 148 \\ 149 149 182 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 183 + 150 150 \\ 151 151 152 152 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -159,16 +159,193 @@ 159 159 160 160 \\ 161 161 162 -**14.5 Tape roll exchange** 196 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** === 163 163 164 - **[[image:attach:20211201_094111.jpg||height="250"]][[image:attach:20211201_094101.jpg||height="250"]]**198 +The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 165 165 200 +* Remove the (almost) empty feeder roll by pulling it upwards. 201 +* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 202 +* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 203 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 204 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 205 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 206 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 207 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 208 +* Attach new tape to the empty roll by using some sticky tape. 209 +* Close tape stabilizer. 210 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 211 + 212 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 213 +** 214 + 166 166 \\ 167 167 168 168 \\ 169 169 219 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 220 + 170 170 \\ 171 171 223 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** === 224 + 225 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 226 + 227 +(% class="code" %) 228 +((( 229 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 230 + password: written on control laptop (changes every 6 months) 231 +))) 232 + 233 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 234 + 172 172 \\ 173 173 237 +Click "Start" icon in kamzik. 238 + 239 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 240 + 241 +---- 242 +{{/layout-cell}} 243 +{{/layout-section}} 244 + 245 +{{layout-section ac:type="two_equal"}} 246 +{{layout-cell}} 247 +**Check list:** 248 + 249 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 250 + 251 +* Open BS1 (//CrystalControl)// 252 +* Put collimator in (//CrystalControl)// 253 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 254 +* Open fast shutter (//CrystalControl)// 255 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 256 +* Close fast shutter (//CrystalControl)// 257 + 174 174 \\ 259 + 260 +**Set run parameters and go 🏃💥** 261 + 262 +1. Set your desired No. of frames 263 +1. Match exposure time with chopper setting 264 +1. Check trigger setting and match to chopper setting 265 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 266 +1. To start the run, click "<Call>" next to //exposure time// 267 + 268 +\\ 269 + 270 +(% style="color: rgb(153,51,102);" %)**//Current bug~://** 271 + 272 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 273 + 274 + 275 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 276 + 277 +(% class="code" %) 278 +((( 279 + cd /gpfs/current/raw/scan_frames 280 + watch "ls -lrt <run number>/ | tail" 281 +\\\\\\\\ 282 +))) 283 +{{/layout-cell}} 284 + 285 +{{layout-cell}} 286 +(% class="wrapped relative-table" style="width: 100.0%;" %) 287 +|=((( 288 +Parameter 289 +)))|=((( 290 +explanation 291 +)))|=(% colspan="1" %)((( 292 +value 293 +))) 294 +|((( 295 +Images number 296 +)))|((( 297 +Set number of frames you want to collect 298 +)))|(% colspan="1" %)((( 299 +usually 100k - 200k, but adjust according to hitrate 300 + 301 +orientation: 10 % hitrate needs at least 100k images 302 +))) 303 +|((( 304 +exposure 305 +)))|((( 306 +exposure time of Eiger 307 + 308 +\\ 309 +)))|(% colspan="1" %)((( 310 +chopper at 133 Hz → 3.7 ms 311 + 312 +chopper at 66 Hz → 7.7 ms 313 + 314 +no chopper → 7.7 ms 315 + 316 +---- 317 +))) 318 +|((( 319 +run id 320 +)))|((( 321 +changes automatically 322 +)))|(% colspan="1" %)((( 323 +\\ 324 +))) 325 +|(% colspan="1" %)((( 326 +Detector distance 327 +)))|(% colspan="1" %)((( 328 +current detector postion readout 329 +)))|(% colspan="1" %)((( 330 +\\ 331 +))) 332 +|(% colspan="1" %)((( 333 +move_detector (distance) 334 +)))|(% colspan="1" %)((( 335 +Set detector distance 336 +)))|(% colspan="1" %)((( 337 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 338 +))) 339 +|(% colspan="1" %)((( 340 +Diode voltage 341 +)))|(% colspan="1" %)((( 342 +read out of diode 343 +)))|(% colspan="1" %)((( 344 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 345 +Call local contact 346 +** 347 +))) 348 +{{/layout-cell}} 349 +{{/layout-section}} 350 + 351 +{{layout-section ac:type="single"}} 352 +{{layout-cell}} 353 +---- 354 + 355 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 356 + 357 +* ((( 358 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 359 + 360 +* Tape roll empty? 361 +* motor connected (icon green)? 362 +))) 363 + 364 +\\ 365 + 366 +* ((( 367 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 368 + 369 +* displayed in green=connected? 370 +* nozzle holder colliding somewhere? 371 +* motor limits reached? → position displayed in red 372 +))) 373 + 374 +\\ 375 + 376 +* ((( 377 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 378 + 379 +* channel turned on? 380 +* Sample empty? 381 +* Nozzle or lines clogged? → flush with water, change nozzle 382 +))) 383 +{{/layout-cell}} 384 +{{/layout-section}} 385 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23 50377291 +236824588 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23 5037729/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824588/14. Serial Crystallography: CFEL TapeDrive