Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,20 @@ 1 -[[image:attach:TapeDrive_beschriftet.PNG||height="400"]][[image:attach:TapeDrive scheme.png||height="400"]] 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 2 2 3 -**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** 4 4 6 +{{toc/}} 7 + 8 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]] 9 + 10 +\\ 11 + 12 +\\ 13 + 14 +\\ 15 + 16 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1RevertfromCrystallographytoTapeDrive(P11staff/CFEL)"/}}**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** === 17 + 5 5 * remove vortex 6 6 * beamstop to out-position? 7 7 * remove goniometer. The airbearing should be stopped (p11/servermotor/eh.1.01) ... ... @@ -50,7 +50,7 @@ 50 50 51 51 \\ 52 52 53 -**14.2 Sample characteristics and preparation** 66 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2Samplecharacteristicsandpreparation"/}}**14.2 Sample characteristics and preparation** === 54 54 55 55 suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 56 56 ... ... @@ -62,40 +62,54 @@ 62 62 63 63 \\ 64 64 65 -**14.3 Connecting sample to ElveFlow, sample exchange 66 -** 78 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3ConnectingsampletoElveFlow,sampleexchange"/}}**14.3 Connecting sample to ElveFlow, sample exchange 79 +** === 67 67 68 - [[image:attach:20211201_095033.jpg||thumbnail="true"height="250"]][[image:attach:20211201_095205.jpg||height="250"]][[image:attach:20211201_095232.jpg||height="250"]]81 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 69 69 70 - \\83 +Be aware to which channel and nozzle line your sample is connected. 71 71 85 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) 86 + 87 + Green → Channel 2, substrate line (nozzle capillary is marked in black) 88 + 89 +[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 90 + 91 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O. 92 + 93 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 94 + 72 72 \\ 73 73 74 -**14.4 TapeDrive operation 75 -** 97 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation 98 +** === 76 76 77 -The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open ,shortly after a small window.100 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 78 78 Now start the client. Same thing, a terminal will open, shortly after a small window. 79 79 80 80 Click 'Devices' in the **client session** to open the control window. 81 81 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 82 82 83 -* **Tape:** 84 -** Click on the 'main tape' icon 85 -** Change the velocity by typing anything from **0.3-3.0 mm/s** 86 -** Common velocity is 1.0-1.5 mm/s 87 -** kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 88 -** [[image:attach:kamzik_tape.PNG||height="400"]] 106 +**Tape** 89 89 108 +* Click on the 'main tape' icon 109 +* Change the velocity by typing anything from **0.3-3.0 mm/s** 110 +* Common velocity is 1.0-1.5 mm/s 111 +* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 90 90 \\ 113 +* [[image:attach:kamzik_tape.PNG||height="400"]] 91 91 92 -* **Sample nozzle:** 93 -** Click an the 'nozzle' icon. 94 -** ((( 95 -The nozzle position can be adjusted in xyz by clicking on the arrows up and down. Step size can be varied, 1mm steps are rather big and should be used carefully, for y-movement always use a stepsize <= 0.5mm. 115 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 116 + 117 +* Click an the 'nozzle' icon. 118 +* ((( 119 +The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 96 96 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 97 -\\Adjust the nozzle position visually until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the X-ray beam (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance. 98 98 122 + 123 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 124 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 125 + 99 99 (% class="wrapped" %) 100 100 |=((( 101 101 \\ ... ... @@ -137,15 +137,23 @@ 137 137 be careful with -z, tape could be pushed out of focus 138 138 ))) 139 139 140 - (% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%)**167 +** 141 141 \\** 142 142 ))) 143 -* *[[image:attach:kamzik_nozzle.PNG||height="400"]]170 +* [[image:attach:kamzik_nozzle.PNG||height="400"]] 144 144 172 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 173 + 174 +* The chiller circulates fluid through the gas nozzle. 175 + 145 145 \\ 146 146 178 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 179 + 147 147 \\ 148 148 182 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 183 + 149 149 \\ 150 150 151 151 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -158,16 +158,176 @@ 158 158 159 159 \\ 160 160 161 -**14.5 Tape roll exchange** 196 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** === 162 162 163 - **[[image:attach:20211201_094111.jpg||height="250"]][[image:attach:20211201_094101.jpg||height="250"]]**198 +The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 164 164 200 +* Remove the (almost) empty feeder roll by pulling it upwards. 201 +* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 202 +* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 203 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 204 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 205 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 206 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 207 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 208 +* Attach new tape to the empty roll by using some sticky tape. 209 +* Close tape stabilizer. 210 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 211 + 212 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 213 +** 214 + 165 165 \\ 166 166 167 167 \\ 168 168 219 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 220 + 169 169 \\ 170 170 223 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** === 224 + 225 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 226 + 227 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 228 + password: //written on control laptop (changes every 6 months)// 229 + 230 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 231 + 171 171 \\ 172 172 234 +**Check list:** 235 + 236 +* Open BS1 (//CrystalControl)// 237 +* Put collimator in (//CrystalControl)// 238 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 239 +* Open fast shutter (//CrystalControl)// 240 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 241 +* Close fast shutter (//CrystalControl)// 242 + 173 173 \\ 244 + 245 +**Start run in kamzik 246 +** 247 + 248 +Click "Start" icon in kamzik. 249 + 250 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 251 + 252 +---- 253 +{{/layout-cell}} 254 +{{/layout-section}} 255 + 256 +{{layout-section ac:type="two_equal"}} 257 +{{layout-cell}} 258 +\\ 259 + 260 +(% class="task-list" %) 261 +((( 262 +{{task reference="/Tasks/Task_16" status="InProgress"}} 263 +(% class="task-list" %) 264 +((( 265 +{{task reference="/Tasks/Task_22" status="InProgress"}} 266 +Set your desired No. of frames 267 +{{/task}} 268 + 269 +{{task reference="/Tasks/Task_17" status="InProgress"}} 270 +Match exposure time with chopper setting 271 +{{/task}} 272 + 273 +{{task reference="/Tasks/Task_18" status="InProgress"}} 274 +Check trigger setting and match to chopper setting 275 +{{/task}} 276 + 277 +{{task reference="/Tasks/Task_19" status="InProgress"}} 278 +Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 279 +{{/task}} 280 + 281 +{{task reference="/Tasks/Task_20" status="InProgress"}} 282 +To start the run, click "<Call>" next to //exposure time// 283 +{{/task}} 284 +))) 285 +{{/task}} 286 +))) 287 +{{/layout-cell}} 288 + 289 +{{layout-cell}} 290 +(% class="wrapped" %) 291 +|=((( 292 +Parameter 293 +)))|=((( 294 +explanation 295 +)))|=(% colspan="1" %)((( 296 +value 297 +))) 298 +|((( 299 +Images number 300 +)))|((( 301 +Set number of frames you want to collect 302 +)))|(% colspan="1" %)((( 303 +usually 100k - 200k, but adjust according to hitrate 304 + 305 +orientation: 10 % hitrate needs at least 100k images 306 +))) 307 +|((( 308 +exposure 309 +)))|((( 310 +exposure time of Eiger 311 + 312 +\\ 313 +)))|(% colspan="1" %)((( 314 +chopper at 133 Hz → 3.7 ms 315 + 316 +chopper at 66 Hz → 7.7 ms 317 + 318 +no chopper → 7.7 ms 319 + 320 +---- 321 +))) 322 +|((( 323 +run id 324 +)))|((( 325 +changes automatically 326 +)))|(% colspan="1" %)((( 327 +\\ 328 +))) 329 +|(% colspan="1" %)((( 330 +Detector distance 331 +)))|(% colspan="1" %)((( 332 +current detector postion readout 333 +)))|(% colspan="1" %)((( 334 +\\ 335 +))) 336 +|(% colspan="1" %)((( 337 +move_detector (distance) 338 +)))|(% colspan="1" %)((( 339 +Set detector distance 340 +)))|(% colspan="1" %)((( 341 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 342 +))) 343 +|(% colspan="1" %)((( 344 +Diode voltage 345 +)))|(% colspan="1" %)((( 346 +read out of diode 347 +)))|(% colspan="1" %)((( 348 +**~~ 0 !!! higher values indicate missaligned beam stop!!!** 349 +))) 350 +{{/layout-cell}} 351 +{{/layout-section}} 352 + 353 +{{layout-section ac:type="single"}} 354 +{{layout-cell}} 355 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 356 + 357 +* ((( 358 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 359 +))) 360 +* ((( 361 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 362 +))) 363 +* ((( 364 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 365 +))) 366 +{{/layout-cell}} 367 +{{/layout-section}} 368 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -235 0390931 +236824567 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/235 039093/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824567/14. Serial Crystallography: CFEL TapeDrive