... ... @@ -1,0 +1,424 @@
1 +{{layout}}
2 +{{layout-section ac:type="single"}}
3 +{{layout-cell}}
4 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]]
5 +
6 +\\
7 +
8 +{{toc minLevel="2"/}}
9 +
10 +\\
11 +
12 +----
13 +
14 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** ==
15 +
16 +suspension of microcrystals, **at least** 200 µL with 20% crystal density (more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.
17 +
18 +Preparation:
19 +
20 +* filter through 30 µm cell filter (green) or 50 µm (yellow) into Eppendorf or Falcon (original!) tube
21 +
22 +[[image:attach:20211201_095534.jpg||height="250"]]
23 +
24 +\\
25 +
26 +----
27 +
28 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}**14.2 Connecting sample to ElveFlow, sample exchange
29 +** ==
30 +
31 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!**
32 +
33 +Be aware to which channel and nozzle line your sample is connected.
34 +
35 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks)
36 +
37 + Green → Channel 2, substrate line (nozzle capillary is marked in black)
38 +
39 +[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]]
40 +
41 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O.
42 +
43 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]]
44 +
45 +\\
46 +
47 +----
48 +
49 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}**14.3 TapeDrive operation
50 +** ==
51 +
52 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window.
53 +Now start the client. Same thing, a terminal will open, shortly after a small window.
54 +
55 +Click 'Devices' in the **client session** to open the control window.
56 +[[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]]
57 +
58 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ====
59 +
60 +* Click the 'main tape' icon
61 +* Change the velocity by typing anything from **0.3-3.0 mm/s**
62 +* Common velocity is 1.0-1.5 mm/s
63 +* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point.
64 +\\
65 +* [[image:attach:kamzik_tape.PNG||height="400"]]
66 +
67 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ====
68 +
69 +* Click on the 'nozzle' icon.
70 +* (((
71 +The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully.
72 +The absolute position is **not calibrated** and therefore changes after each restart of kamzik.
73 +
74 +
75 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%)
76 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments.
77 +
78 +(% class="wrapped" %)
79 +|=(((
80 +\\
81 +)))|=(((
82 +direction
83 +)))|=(((
84 +recommended step size
85 +for visual adjustment
86 +)))|=(% colspan="1" %)(((
87 +recommended step size
88 +during data collection
89 +)))
90 +|(((
91 ++x
92 +)))|(((
93 +away from X-ray interaction point
94 +)))|(((
95 +1.0 - 0.5 mm
96 +)))|(% colspan="1" %)(((
97 +0.1 - 0.2 mm
98 +)))
99 +|(((
100 ++y
101 +)))|(((
102 +up
103 +)))|(((
104 +1.0 - 0.5 mm
105 +)))|(% colspan="1" %)(((
106 +0.1 - 0.2 mm
107 +)))
108 +|(((
109 ++z
110 +)))|(((
111 +towards detector tower, away from tape
112 +)))|(((
113 +0.5 - 0.2 mm
114 +)))|(% colspan="1" %)(((
115 +0.1 - 0.2 mm
116 +be careful with -z, tape could be pushed out of focus
117 +)))
118 +
119 +**
120 +\\**
121 +)))
122 +* [[image:attach:kamzik_nozzle.PNG||height="400"]]
123 +
124 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ====
125 +
126 +* The chiller circulates fluid through the gas nozzle.
127 +
128 +\\
129 +
130 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ====
131 +
132 +\\
133 +
134 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ====
135 +
136 +\\
137 +
138 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
139 +
140 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611
141 + password: //written on control laptop (changes every 6 months)
142 +//
143 +
144 +\\
145 +
146 +\\
147 +
148 +----
149 +
150 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}}**14.4 Tape roll exchange** ==
151 +
152 +The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s).
153 +
154 +* Remove the (almost) empty feeder roll by pulling it upwards.
155 +* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!**
156 +* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm**
157 +* Cut the first cm of the new tape roll, directly behind the black sticky part.
158 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll.
159 +* Open magnetic tape stabilizer on the **left side**. (% style="color: rgb(255,0,0);" %)//!!!BEAMSTOP!!!//
160 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s).
161 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded.
162 +* Attach new tape to the empty roll by using some sticky tape.
163 +* Close tape stabilizer.
164 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape".
165 +
166 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]]
167 +**
168 +
169 +\\
170 +
171 +\\
172 +
173 +**
174 +**
175 +{{/layout-cell}}
176 +{{/layout-section}}
177 +
178 +{{layout-section ac:type="single"}}
179 +{{layout-cell}}
180 +----
181 +
182 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}}**14.5 Chopper** ==
183 +
184 +start chopper gui from terminal:
185 +
186 +(% class="code" %)
187 +(((
188 + cd /gpfs/local/shared/ChopperControl
189 +)))
190 +
191 +(% class="code" %)
192 +(((
193 + python chopperControl.py
194 +\\\\
195 +)))
196 +{{/layout-cell}}
197 +{{/layout-section}}
198 +
199 +{{layout-section ac:type="two_equal"}}
200 +{{layout-cell}}
201 + [[image:attach:20211212_233140.jpg||height="250"]]
202 +{{/layout-cell}}
203 +
204 +{{layout-cell}}
205 +**Chopper → no Chopper**
206 +
207 +* decrease frequency by max. 10 Hz steps\\
208 +** click arrow down 10x, "Set", arrow down 10x, "Set", ....
209 +* at frequency = 10 Hz, click "Stop"
210 +* set "Hole" to <none> (% style="color: rgb(255,0,0);" %)//Takes some minutes//
211 +
212 +(% style="color: rgb(0,0,0);" %)**no Chopper → Chopper**
213 +
214 +* (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes//
215 +* (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps
216 +** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", .....
217 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms (technical exposure will always be 7.7 ms, since max. frame rate is 133 Hz
218 +//
219 +{{/layout-cell}}
220 +{{/layout-section}}
221 +
222 +{{layout-section ac:type="single"}}
223 +{{layout-cell}}
224 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** ==
225 +
226 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
227 +
228 +(% class="code" %)
229 +(((
230 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611
231 + password: written on control laptop (changes every 6 months)
232 +)))
233 +
234 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password//
235 +
236 +\\
237 +{{/layout-cell}}
238 +{{/layout-section}}
239 +
240 +{{layout-section ac:type="two_left_sidebar"}}
241 +{{layout-cell}}
242 +**Check list:**
243 +
244 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!//
245 +
246 +(% style="color: rgb(0,0,0);" %)Click "Run" icon in kamzik.
247 +
248 +* Put collimator in
249 +** Put detector distance 200 in //prepare_for_measurement (      )
250 +//
251 +** Click "<Call>" next to //prepare_for_measurement//
252 +
253 +\\
254 +
255 +* Open beam shutter BS1 in //CrystalControl //or// P11 XRayFeed //
256 +{{/layout-cell}}
257 +
258 +{{layout-cell}}
259 +[[image:attach:kamzik_safety.PNG||height="400"]]
260 +{{/layout-cell}}
261 +{{/layout-section}}
262 +
263 +{{layout-section ac:type="single"}}
264 +{{layout-cell}}
265 +----
266 +
267 +[[image:attach:kamzik_run-tile.jpg||height="400"]]
268 +
269 +----
270 +{{/layout-cell}}
271 +{{/layout-section}}
272 +
273 +{{layout-section ac:type="two_equal"}}
274 +{{layout-cell}}
275 +**Set run parameters and go 🏃💥**
276 +
277 +1. Set your desired No. of frames
278 +1. Match exposure time with chopper setting or set desired exposure time
279 +1. Check trigger setting and match to chopper setting
280 +1. To start the run, click "<Call>" next to //start_run (exposure    )
281 +//
282 +
283 +\\
284 +
285 +\\
286 +
287 +**After data collection/Before entering the exp. hutch:**
288 +
289 +1. Go to "Safety" in kamzik.
290 +1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically:
291 +11. Drive the collimator out
292 +11. Drive the detector back to 1500 mm
293 +1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left).
294 +
295 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]]
296 +{{/layout-cell}}
297 +
298 +{{layout-cell}}
299 +(% class="wrapped relative-table" style="width: 100.0%;" %)
300 +|=(((
301 +Parameter
302 +)))|=(((
303 +explanation
304 +)))|=(% colspan="1" %)(((
305 +value
306 +)))
307 +|(((
308 +Images number
309 +)))|(((
310 +Set number of frames you want to collect
311 +)))|(% colspan="1" %)(((
312 +usually 100k - 200k, but adjust according to hitrate
313 +
314 +orientation: 10 % hitrate needs at least 100k images
315 +)))
316 +|(((
317 +exposure
318 +)))|(((
319 +exposure time of Eiger
320 +
321 +\\
322 +)))|(% colspan="1" %)(((
323 +chopper at 133 Hz → 7.7 ms (opening time will be 3.7)
324 +
325 +chopper at 66 Hz   → 7.7 ms
326 +
327 +no chopper            → 7.7 ms
328 +
329 +----
330 +)))
331 +|(((
332 +run id
333 +)))|(((
334 +changes automatically
335 +)))|(% colspan="1" %)(((
336 +\\
337 +)))
338 +|(% colspan="1" %)(((
339 +Detector distance
340 +)))|(% colspan="1" %)(((
341 +current detector postion readout
342 +)))|(% colspan="1" %)(((
343 +\\
344 +)))
345 +|(% colspan="1" %)(((
346 +move_detector (distance)
347 +)))|(% colspan="1" %)(((
348 +Set detector distance
349 +)))|(% colspan="1" %)(((
350 +200.0 mm   (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>"
351 +)))
352 +{{/layout-cell}}
353 +{{/layout-section}}
354 +
355 +{{layout-section ac:type="single"}}
356 +{{layout-cell}}
357 +----
358 +
359 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Troubleshooting"/}}**14.7 Troubleshooting** ==
360 +
361 +* (((
362 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ====
363 +
364 +* Tape roll empty?
365 +* motor connected (icon green)?
366 +)))
367 +
368 +\\
369 +
370 +* (((
371 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ====
372 +
373 +* displayed in green=connected?
374 +* nozzle holder colliding somewhere?
375 +* motor limits reached? → position displayed in red
376 +)))
377 +
378 +\\
379 +
380 +* (((
381 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ====
382 +
383 +* channel turned on?
384 +* Sample empty?
385 +* Nozzle or lines clogged? → flush with water, change nozzle
386 +)))
387 +
388 +\\
389 +
390 +* (((
391 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Simplonfilewriter/eigerstreamissues"/}}Simplon filewriter/eiger stream issues ====
392 +
393 +* First, restart kamzik (server+client) and see if this solves the issue
394 +* If not, restart the Simplon server (in Astor → haspp11exp03, right click on Simplon/EH.1 and restart)
395 +* (((
396 +If nothing works, kill the Simplon process and then start the server again:* (((
397 +(% class="code" %)
398 +(((
399 +ssh haspp11exp03
400 +)))
401 +)))
402 +* (((
403 +(% class="code" %)
404 +(((
405 +ps -ef | grep Simplon
406 +)))
407 +)))
408 +* (((
409 +(% class="code" %)
410 +(((
411 +kill -9 simplon_process_id
412 +)))
413 +)))
414 +)))
415 +)))
416 +{{/layout-cell}}
417 +{{/layout-section}}
418 +
419 +{{layout-section ac:type="single"}}
420 +{{layout-cell}}
421 +\\
422 +{{/layout-cell}}
423 +{{/layout-section}}
424 +{{/layout}}
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -235031925
1 +254729368
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/11/pages/235031925/14. Serial Crystallography: CFEL TapeDrive
1 +https://confluence.desy.de/spaces/11/pages/254729368/14. Serial Crystallography: CFEL TapeDrive