Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +2,17 @@ 1 -[[image:attach:TapeDrive_beschriftet.PNG||height="400"]][[image:attach:TapeDrive scheme.png||height="400"]] 2 2 3 -**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** 4 4 3 +{{toc/}} 4 + 5 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]] 6 + 7 +\\ 8 + 9 +\\ 10 + 11 +\\ 12 + 13 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1RevertfromCrystallographytoTapeDrive(P11staff/CFEL)"/}}**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** === 14 + 5 5 * remove vortex 6 6 * beamstop to out-position? 7 7 * remove goniometer. The airbearing should be stopped (p11/servermotor/eh.1.01) ... ... @@ -50,7 +50,7 @@ 50 50 51 51 \\ 52 52 53 -**14.2 Sample characteristics and preparation** 63 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2Samplecharacteristicsandpreparation"/}}**14.2 Sample characteristics and preparation** === 54 54 55 55 suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 56 56 ... ... @@ -62,17 +62,27 @@ 62 62 63 63 \\ 64 64 65 -**14.3 Connecting sample to ElveFlow, sample exchange 66 -** 75 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3ConnectingsampletoElveFlow,sampleexchange"/}}**14.3 Connecting sample to ElveFlow, sample exchange 76 +** === 67 67 68 - [[image:attach:20211201_095033.jpg||thumbnail="true"height="250"]][[image:attach:20211201_095205.jpg||height="250"]][[image:attach:20211201_095232.jpg||height="250"]]78 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 69 69 70 - \\80 +Be aware to which channel and nozzle line your sample is connected. 71 71 82 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) 83 + 84 + Green → Channel 2, substrate line (nozzle capillary is marked in black) 85 + 86 +[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 87 + 88 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O. 89 + 90 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 91 + 72 72 \\ 73 73 74 -**14.4 TapeDrive operation 75 -** 94 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation 95 +** === 76 76 77 77 The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 78 78 Now start the client. Same thing, a terminal will open, shortly after a small window. ... ... @@ -80,24 +80,26 @@ 80 80 Click 'Devices' in the **client session** to open the control window. 81 81 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 82 82 83 -* **Tape:** 84 -** Click on the 'main tape' icon 85 -** Change the velocity by typing anything from **0.3-3.0 mm/s** 86 -** Common velocity is 1.0-1.5 mm/s 87 -** kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 88 -\\ 89 -** [[image:attach:kamzik_tape.PNG||height="400"]] 103 +**Tape** 90 90 105 +* Click on the 'main tape' icon 106 +* Change the velocity by typing anything from **0.3-3.0 mm/s** 107 +* Common velocity is 1.0-1.5 mm/s 108 +* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 91 91 \\ 110 +* [[image:attach:kamzik_tape.PNG||height="400"]] 92 92 93 -* **Sample nozzle:** 94 -** Click an the 'nozzle' icon. 95 -** ((( 112 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 113 + 114 +* Click an the 'nozzle' icon. 115 +* ((( 96 96 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 97 97 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 98 -\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 99 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 100 100 119 + 120 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 121 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 122 + 101 101 (% class="wrapped" %) 102 102 |=((( 103 103 \\ ... ... @@ -142,12 +142,20 @@ 142 142 ** 143 143 \\** 144 144 ))) 145 -* *[[image:attach:kamzik_nozzle.PNG||height="400"]]167 +* [[image:attach:kamzik_nozzle.PNG||height="400"]] 146 146 169 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 170 + 171 +* The chiller circulates fluid through the gas nozzle. 172 + 147 147 \\ 148 148 175 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 176 + 149 149 \\ 150 150 179 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 180 + 151 151 \\ 152 152 153 153 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -160,17 +160,23 @@ 160 160 161 161 \\ 162 162 163 -**14.5 Tape roll exchange** 193 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** === 164 164 165 165 The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 166 166 167 167 * Remove the (almost) empty feeder roll by pulling it upwards. 168 -* Cut the tape with some cm overlap to glue to the new roll. 198 +* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 169 169 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 170 -* Cut the first cm of the new tape roll, directly before the black sticky part. 171 -* Use this sticky part to attach the end of the old 200 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 201 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 202 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 203 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 204 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 205 +* Attach new tape to the empty roll by using some sticky tape. 206 +* Close tape stabilizer. 207 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 172 172 173 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 209 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 174 174 ** 175 175 176 176 \\ ... ... @@ -177,8 +177,142 @@ 177 177 178 178 \\ 179 179 216 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 217 + 180 180 \\ 181 181 220 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** === 221 + 222 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 223 + 224 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 225 + password: //written on control laptop (changes every 6 months)// 226 + 227 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 228 + 182 182 \\ 183 183 231 +**Check list:** 232 + 233 +* Open BS1 (//CrystalControl)// 234 +* Put collimator in (//CrystalControl)// 235 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 236 +* Open fast shutter (//CrystalControl)// 237 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 238 +* Close fast shutter (//CrystalControl)// 239 + 184 184 \\ 241 + 242 +**Start run in kamzik 243 +** 244 + 245 +Click "Start" icon in kamzik. 246 + 247 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 248 + 249 +|=((( 250 +Parameter 251 +)))|=((( 252 +explanation 253 +)))|=(% colspan="1" %)((( 254 +value 255 +))) 256 +|((( 257 +Images number 258 +)))|((( 259 +Set number of frames you want to collect 260 +)))|(% colspan="1" %)((( 261 +usually 100k - 200k, but adjust according to hitrate 262 + 263 +orientation: 10 % hitrate needs at least 100k images 264 +))) 265 +|((( 266 +exposure 267 +)))|((( 268 +exposure time of Eiger 269 + 270 +\\ 271 +)))|(% colspan="1" %)((( 272 +chopper at 133 Hz → 3.7 ms 273 + 274 +chopper at 66 Hz → 7.7 ms 275 + 276 +no chopper → 7.7 ms 277 + 278 +---- 279 +))) 280 +|((( 281 +run id 282 +)))|((( 283 +changes automatically 284 +)))|(% colspan="1" %)((( 285 +\\ 286 +))) 287 +|(% colspan="1" %)((( 288 +Detector distance 289 +)))|(% colspan="1" %)((( 290 +current detector postion readout 291 +)))|(% colspan="1" %)((( 292 +\\ 293 +))) 294 +|(% colspan="1" %)((( 295 +move_detector (distance) 296 +)))|(% colspan="1" %)((( 297 +Set detector distance 298 +)))|(% colspan="1" %)((( 299 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 300 +))) 301 +|(% colspan="1" %)((( 302 +Diode voltage 303 +)))|(% colspan="1" %)((( 304 +read out of diode 305 +)))|(% colspan="1" %)((( 306 +**~~ 0 !!! higher values indicate missaligned beam stop!!!** 307 +))) 308 + 309 +---- 310 + 311 +(% class="task-list" %) 312 +((( 313 +{{task reference="/Tasks/Task_6" status="InProgress"}} 314 +Set your desired No. of frames 315 +{{/task}} 316 + 317 +{{task reference="/Tasks/Task_7" status="InProgress"}} 318 +Match exposure time with chopper setting 319 +{{/task}} 320 + 321 +{{task reference="/Tasks/Task_8" status="InProgress"}} 322 +Check trigger setting and match to chopper setting 323 +{{/task}} 324 + 325 +{{task reference="/Tasks/Task_9" status="InProgress"}} 326 +Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 327 +{{/task}} 328 + 329 +{{task reference="/Tasks/Task_10" status="InProgress"}} 330 +To start the run, click "<Call>" next to //exposure time// 331 +{{/task}} 332 +))) 333 + 334 +---- 335 + 336 +\\ 337 + 338 +\\ 339 + 340 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 341 + 342 +* ((( 343 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 344 +))) 345 +* ((( 346 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 347 +))) 348 +* ((( 349 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 350 +))) 351 + 352 +\\ 353 + 354 +\\
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23 50394241 +236824562 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23 5039424/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824562/14. Serial Crystallography: CFEL TapeDrive