Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -65,16 +65,8 @@ 65 65 **14.3 Connecting sample to ElveFlow, sample exchange 66 66 ** 67 67 68 - After filtration, screwthe ElveFlowconnector to your Eppendorf or Falcontube.Make sure that theyellow-ish linegoes to the bttomof your tube. You can adjustthe lengthby unscrewingthe blue fittingontopand pushing/pullingtheyellow-ish line. **Don't forget to tigthenthe blue fitting afterwards!**68 +[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]][[image:attach:20211201_095205.jpg||height="250"]][[image:attach:20211201_095232.jpg||height="250"]] 69 69 70 -Be aware to which channel and nozzle line your sample is connected. 71 - 72 -Red → Channel 1, crystal line (nozzle capillary without marks) 73 - 74 -Green → Channel 2, substrate line (nozzle capillary is marked in black) 75 - 76 -[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 77 - 78 78 \\ 79 79 80 80 \\ ... ... @@ -82,82 +82,22 @@ 82 82 **14.4 TapeDrive operation 83 83 ** 84 84 85 -The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open andshortly after a small window.77 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open, shortly after a small window. 86 86 Now start the client. Same thing, a terminal will open, shortly after a small window. 87 - 88 -Click 'Devices' in the **client session** to open the control window. 89 89 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 90 90 91 91 * **Tape:** 92 92 ** Click on the 'main tape' icon 93 -** Change the velocity by typing anything from **0.3-3.0 mm/s**83 +** Change the velocity by typing anything from 0.3-3.0 mm/s 94 94 ** Common velocity is 1.0-1.5 mm/s 95 -** kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 96 -\\ 97 97 ** [[image:attach:kamzik_tape.PNG||height="400"]] 98 98 99 99 \\ 100 100 101 -* **Sample nozzle:** 102 -** Click an the 'nozzle' icon. 103 -** ((( 104 -The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 105 -The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 106 -\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 107 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 108 - 109 -(% class="wrapped" %) 110 -|=((( 111 111 \\ 112 -)))|=((( 113 -direction 114 -)))|=((( 115 -recommended step size 116 -for visual adjustment 117 -)))|=(% colspan="1" %)((( 118 -recommended step size 119 -during data collection 120 -))) 121 -|((( 122 -+x 123 -)))|((( 124 -away from X-ray interaction point 125 -)))|((( 126 -1.0 - 0.5 mm 127 -)))|(% colspan="1" %)((( 128 -0.1 - 0.2 mm 129 -))) 130 -|((( 131 -+y 132 -)))|((( 133 -up 134 -)))|((( 135 -1.0 - 0.5 mm 136 -)))|(% colspan="1" %)((( 137 -0.1 - 0.2 mm 138 -))) 139 -|((( 140 -+z 141 -)))|((( 142 -towards detector tower, away from tape 143 -)))|((( 144 -0.5 - 0.2 mm 145 -)))|(% colspan="1" %)((( 146 -0.1 - 0.2 mm 147 -be careful with -z, tape could be pushed out of focus 148 -))) 149 149 150 -** 151 -\\** 152 -))) 153 -** [[image:attach:kamzik_nozzle.PNG||height="400"]] 154 - 155 155 \\ 156 156 157 -\\ 158 - 159 -\\ 160 - 161 161 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 162 162 163 163 xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 ... ... @@ -170,17 +170,8 @@ 170 170 171 171 **14.5 Tape roll exchange** 172 172 173 - The tapestopsautomatically at98% used length, if you need to changethe rolls for orther reasons, stopthetape (velocity=0.0 mm/s).105 +**[[image:attach:20211201_094111.jpg||height="250"]][[image:attach:20211201_094101.jpg||height="250"]]** 174 174 175 -* Remove the (almost) empty feeder roll by pulling it upwards. 176 -* Cut the tape with some cm overlap to glue to the new roll. 177 -* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 178 -* Cut the first cm of the new tape roll, directly before the black sticky part. 179 -* Use this sticky part to attach the end of the old 180 - 181 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 182 -** 183 - 184 184 \\ 185 185 186 186 \\
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23503 94501 +235037525 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23503 9450/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/235037525/14. Serial Crystallography: CFEL TapeDrive