Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,16 @@ 1 -[[image:attach:TapeDrive_beschriftet.PNG||height="400"]][[image:attach:TapeDrive scheme.png||height="400"]] 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 4 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="250"]] 2 2 3 - **14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)**6 +\\ 4 4 8 +\\ 9 + 10 +\\ 11 + 12 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1RevertfromCrystallographytoTapeDrive(P11staff/CFEL)"/}}**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** === 13 + 5 5 * remove vortex 6 6 * beamstop to out-position? 7 7 * remove goniometer. The airbearing should be stopped (p11/servermotor/eh.1.01) ... ... @@ -50,7 +50,7 @@ 50 50 51 51 \\ 52 52 53 -**14.2 Sample characteristics and preparation** 62 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2Samplecharacteristicsandpreparation"/}}**14.2 Sample characteristics and preparation** === 54 54 55 55 suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 56 56 ... ... @@ -62,25 +62,27 @@ 62 62 63 63 \\ 64 64 65 -**14.3 Connecting sample to ElveFlow, sample exchange 66 -** 74 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3ConnectingsampletoElveFlow,sampleexchange"/}}**14.3 Connecting sample to ElveFlow, sample exchange 75 +** === 67 67 68 -After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bttom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 77 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 69 69 70 70 Be aware to which channel and nozzle line your sample is connected. 71 71 72 -Red → Channel 1, crystal line (nozzle capillary without marks) 81 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) 73 73 74 -Green → Channel 2, substrate line (nozzle capillary is marked in black) 83 + Green → Channel 2, substrate line (nozzle capillary is marked in black) 75 75 76 76 [[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 77 77 78 - \\87 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O. 79 79 89 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 90 + 80 80 \\ 81 81 82 -**14.4 TapeDrive operation 83 -** 93 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation 94 +** === 84 84 85 85 The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 86 86 Now start the client. Same thing, a terminal will open, shortly after a small window. ... ... @@ -88,24 +88,26 @@ 88 88 Click 'Devices' in the **client session** to open the control window. 89 89 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 90 90 91 -* **Tape:** 92 -** Click on the 'main tape' icon 93 -** Change the velocity by typing anything from **0.3-3.0 mm/s** 94 -** Common velocity is 1.0-1.5 mm/s 95 -** kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 96 -\\ 97 -** [[image:attach:kamzik_tape.PNG||height="400"]] 102 +**Tape** 98 98 104 +* Click on the 'main tape' icon 105 +* Change the velocity by typing anything from **0.3-3.0 mm/s** 106 +* Common velocity is 1.0-1.5 mm/s 107 +* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 99 99 \\ 109 +* [[image:attach:kamzik_tape.PNG||height="400"]] 100 100 101 -* **Sample nozzle:** 102 -** Click an the 'nozzle' icon. 103 -** ((( 111 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 112 + 113 +* Click an the 'nozzle' icon. 114 +* ((( 104 104 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 105 105 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 106 -\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 107 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 108 108 118 + 119 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 120 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 121 + 109 109 (% class="wrapped" %) 110 110 |=((( 111 111 \\ ... ... @@ -150,12 +150,20 @@ 150 150 ** 151 151 \\** 152 152 ))) 153 -* *[[image:attach:kamzik_nozzle.PNG||height="400"]]166 +* [[image:attach:kamzik_nozzle.PNG||height="400"]] 154 154 168 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 169 + 170 +* The chiller circulates fluid through the gas nozzle. 171 + 155 155 \\ 156 156 174 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 175 + 157 157 \\ 158 158 178 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 179 + 159 159 \\ 160 160 161 161 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -168,17 +168,23 @@ 168 168 169 169 \\ 170 170 171 -**14.5 Tape roll exchange** 192 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** === 172 172 173 173 The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 174 174 175 175 * Remove the (almost) empty feeder roll by pulling it upwards. 176 -* Cut the tape with some cm overlap to glue to the new roll. 197 +* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 177 177 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 178 -* Cut the first cm of the new tape roll, directly before the black sticky part. 179 -* Use this sticky part to attach the end of the old 199 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 200 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 201 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 202 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 203 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 204 +* Attach new tape to the empty roll by using some sticky tape. 205 +* Close tape stabilizer. 206 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 180 180 181 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 208 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 182 182 ** 183 183 184 184 \\ ... ... @@ -185,8 +185,213 @@ 185 185 186 186 \\ 187 187 215 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-"/}}** 216 +** === 217 +{{/layout-cell}} 218 +{{/layout-section}} 219 + 220 +{{layout-section ac:type="single"}} 221 +{{layout-cell}} 222 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Chopper"/}}**14.7 Chopper** === 223 + 224 +start chopper gui from terminal: 225 + 226 +(% class="code" %) 227 +((( 228 + cd /gpfs/local/shared/ChopperControl 229 +))) 230 + 231 +(% class="code" %) 232 +((( 233 + python chopperControl.py 234 +))) 235 +{{/layout-cell}} 236 +{{/layout-section}} 237 + 238 +{{layout-section ac:type="two_equal"}} 239 +{{layout-cell}} 240 + [[image:attach:20211212_233140.jpg||height="250"]] 241 +{{/layout-cell}} 242 + 243 +{{layout-cell}} 244 +**Chopper → no Chopper** 245 + 246 +* decrease frequency by max. 10 Hz steps\\ 247 +** click arrow down 10x, "Set", arrow down 10x, "Set", .... 248 +* at frequency = 10 Hz, click "Stop" 249 +* set "Hole" to <none> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 250 + 251 +(% style="color: rgb(0,0,0);" %)**no Chopper → Chopper** 252 + 253 +* (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 254 +* (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 255 +** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 256 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 257 +{{/layout-cell}} 258 +{{/layout-section}} 259 + 260 +{{layout-section ac:type="single"}} 261 +{{layout-cell}} 262 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Datacollection"/}}**14.8 Data collection** === 263 + 264 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 265 + 266 +(% class="code" %) 267 +((( 268 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 269 + password: written on control laptop (changes every 6 months) 270 +))) 271 + 272 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 273 + 188 188 \\ 189 189 276 +Click "Start" icon in kamzik. 277 + 278 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 279 + 280 +---- 281 +{{/layout-cell}} 282 +{{/layout-section}} 283 + 284 +{{layout-section ac:type="two_equal"}} 285 +{{layout-cell}} 286 +**Check list:** 287 + 288 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 289 + 290 +* Open BS1 (//CrystalControl)// 291 +* Put collimator in (//CrystalControl)// 292 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 293 +* Open fast shutter (//CrystalControl)// 294 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 295 +* Close fast shutter (//CrystalControl)// 296 + 190 190 \\ 191 191 299 +**Set run parameters and go 🏃💥** 300 + 301 +1. Set your desired No. of frames 302 +1. Match exposure time with chopper setting 303 +1. Check trigger setting and match to chopper setting 304 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 305 +1. To start the run, click "<Call>" next to //exposure time// 306 + 192 192 \\ 308 + 309 +(% style="color: rgb(153,51,102);" %)**//Current bug~://** 310 + 311 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 312 + 313 + 314 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 315 + 316 +(% class="code" %) 317 +((( 318 + cd /gpfs/current/raw/scan_frames 319 + watch "ls -lrt <run number>/ | tail" 320 +\\\\\\\\ 321 +))) 322 +{{/layout-cell}} 323 + 324 +{{layout-cell}} 325 +(% class="wrapped relative-table" style="width: 100.0%;" %) 326 +|=((( 327 +Parameter 328 +)))|=((( 329 +explanation 330 +)))|=(% colspan="1" %)((( 331 +value 332 +))) 333 +|((( 334 +Images number 335 +)))|((( 336 +Set number of frames you want to collect 337 +)))|(% colspan="1" %)((( 338 +usually 100k - 200k, but adjust according to hitrate 339 + 340 +orientation: 10 % hitrate needs at least 100k images 341 +))) 342 +|((( 343 +exposure 344 +)))|((( 345 +exposure time of Eiger 346 + 347 +\\ 348 +)))|(% colspan="1" %)((( 349 +chopper at 133 Hz → 3.7 ms 350 + 351 +chopper at 66 Hz → 7.7 ms 352 + 353 +no chopper → 7.7 ms 354 + 355 +---- 356 +))) 357 +|((( 358 +run id 359 +)))|((( 360 +changes automatically 361 +)))|(% colspan="1" %)((( 362 +\\ 363 +))) 364 +|(% colspan="1" %)((( 365 +Detector distance 366 +)))|(% colspan="1" %)((( 367 +current detector postion readout 368 +)))|(% colspan="1" %)((( 369 +\\ 370 +))) 371 +|(% colspan="1" %)((( 372 +move_detector (distance) 373 +)))|(% colspan="1" %)((( 374 +Set detector distance 375 +)))|(% colspan="1" %)((( 376 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 377 +))) 378 +|(% colspan="1" %)((( 379 +Diode voltage 380 +)))|(% colspan="1" %)((( 381 +read out of diode 382 +)))|(% colspan="1" %)((( 383 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 384 +Call local contact 385 +** 386 +))) 387 +{{/layout-cell}} 388 +{{/layout-section}} 389 + 390 +{{layout-section ac:type="single"}} 391 +{{layout-cell}} 392 +---- 393 + 394 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.9Troubleshooting"/}}14.9 Troubleshooting === 395 + 396 +* ((( 397 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 398 + 399 +* Tape roll empty? 400 +* motor connected (icon green)? 401 +))) 402 + 403 +\\ 404 + 405 +* ((( 406 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 407 + 408 +* displayed in green=connected? 409 +* nozzle holder colliding somewhere? 410 +* motor limits reached? → position displayed in red 411 +))) 412 + 413 +\\ 414 + 415 +* ((( 416 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 417 + 418 +* channel turned on? 419 +* Sample empty? 420 +* Nozzle or lines clogged? → flush with water, change nozzle 421 +))) 422 +{{/layout-cell}} 423 +{{/layout-section}} 424 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23 50394501 +236824593 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23 5039450/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824593/14. Serial Crystallography: CFEL TapeDrive