Last modified by chatzies on 2025-11-27 11:35

From version 22.1
edited by ahenkel
on 2021-12-03 11:26
Change comment: There is no comment for this version
To version 41.1
edited by ahenkel
on 2021-12-12 23:20
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,20 @@
1 -[[image:attach:TapeDrive_beschriftet.PNG||height="400"]][[image:attach:TapeDrive scheme.png||height="400"]]
1 +{{layout}}
2 +{{layout-section ac:type="single"}}
3 +{{layout-cell}}
2 2  
3 -**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)**
4 4  
6 +{{toc/}}
7 +
8 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]]
9 +
10 +\\
11 +
12 +\\
13 +
14 +\\
15 +
16 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1RevertfromCrystallographytoTapeDrive(P11staff/CFEL)"/}}**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** ===
17 +
5 5  * remove vortex
6 6  * beamstop to out-position?
7 7  * remove goniometer. The airbearing should be stopped (p11/servermotor/eh.1.01)
... ... @@ -50,7 +50,7 @@
50 50  
51 51  \\
52 52  
53 -**14.2 Sample characteristics and preparation**
66 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2Samplecharacteristicsandpreparation"/}}**14.2 Sample characteristics and preparation** ===
54 54  
55 55  suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.
56 56  
... ... @@ -62,25 +62,27 @@
62 62  
63 63  \\
64 64  
65 -**14.3 Connecting sample to ElveFlow, sample exchange
66 -**
78 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3ConnectingsampletoElveFlow,sampleexchange"/}}**14.3 Connecting sample to ElveFlow, sample exchange
79 +** ===
67 67  
68 68  After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!**
69 69  
70 70  Be aware to which channel and nozzle line your sample is connected.
71 71  
72 - Red → Channel 1, crystal line (nozzle capillary without marks)
85 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks)
73 73  
74 74   Green → Channel 2, substrate line (nozzle capillary is marked in black)
75 75  
76 76  [[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]]
77 77  
78 -\\
91 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O.
79 79  
93 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]]
94 +
80 80  \\
81 81  
82 -**14.4 TapeDrive operation
83 -**
97 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation
98 +** ===
84 84  
85 85  The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window.
86 86  Now start the client. Same thing, a terminal will open, shortly after a small window.
... ... @@ -88,24 +88,26 @@
88 88  Click 'Devices' in the **client session** to open the control window.
89 89  [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]]
90 90  
91 -* **Tape:**
92 -** Click on the 'main tape' icon
93 -** Change the velocity by typing anything from **0.3-3.0 mm/s**
94 -** Common velocity is 1.0-1.5 mm/s
95 -** kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point.
96 -\\
97 -** [[image:attach:kamzik_tape.PNG||height="400"]]
106 +**Tape**
98 98  
108 +* Click on the 'main tape' icon
109 +* Change the velocity by typing anything from **0.3-3.0 mm/s**
110 +* Common velocity is 1.0-1.5 mm/s
111 +* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point.
99 99  \\
113 +* [[image:attach:kamzik_tape.PNG||height="400"]]
100 100  
101 -* **Sample nozzle:**
102 -** Click an the 'nozzle' icon.
103 -** (((
115 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ====
116 +
117 +* Click an the 'nozzle' icon.
118 +* (((
104 104  The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully.
105 105  The absolute position is **not calibrated** and therefore changes after each restart of kamzik.
106 -\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%)
107 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments.
108 108  
122 +
123 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%)
124 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments.
125 +
109 109  (% class="wrapped" %)
110 110  |=(((
111 111  \\
... ... @@ -150,12 +150,20 @@
150 150  **
151 151  \\**
152 152  )))
153 -** [[image:attach:kamzik_nozzle.PNG||height="400"]]
170 +* [[image:attach:kamzik_nozzle.PNG||height="400"]]
154 154  
172 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ====
173 +
174 +* The chiller circulates fluid through the gas nozzle.
175 +
155 155  \\
156 156  
178 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ====
179 +
157 157  \\
158 158  
182 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ====
183 +
159 159  \\
160 160  
161 161  Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
... ... @@ -168,7 +168,7 @@
168 168  
169 169  \\
170 170  
171 -**14.5 Tape roll exchange**
196 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** ===
172 172  
173 173  The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s).
174 174  
... ... @@ -175,15 +175,16 @@
175 175  * Remove the (almost) empty feeder roll by pulling it upwards.
176 176  * Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!**
177 177  * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm**
178 -* Cut the first cm of the new tape roll, directly before the black sticky part.
179 -* Use this sticky part to attach the end of the old tape to the new roll. Place new roll on roll holder.
180 -* Open magnetic tape stabilizer.
181 -* Start the tape (3mm/s). Once the connetion side (black sticky part) has arrived at the collector roll, stop the tape (0mm/s).
182 -* Again, cut the tape directly in front of the black mark. Replace the the old roll with the **empty **one. Old roll can be discarded.
183 -* Attach new tape to the empty roll by using the black sticky part.
203 +* Cut the first cm of the new tape roll, directly behind the black sticky part.
204 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll.
205 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!//
206 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s).
207 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded.
208 +* Attach new tape to the empty roll by using some sticky tape.
184 184  * Close tape stabilizer.
210 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape".
185 185  
186 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]]
212 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]]
187 187  **
188 188  
189 189  \\
... ... @@ -190,8 +190,170 @@
190 190  
191 191  \\
192 192  
219 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** ===
220 +
193 193  \\
194 194  
223 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** ===
224 +
225 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
226 +
227 +(% class="code" %)
228 +(((
229 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611
230 + password: written on control laptop (changes every 6 months)
231 +)))
232 +
233 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password//
234 +
195 195  \\
196 196  
237 +Click "Start" icon in kamzik.
238 +
239 +[[image:attach:kamzik_run-tile.jpg||height="400"]]
240 +
241 +----
242 +{{/layout-cell}}
243 +{{/layout-section}}
244 +
245 +{{layout-section ac:type="two_equal"}}
246 +{{layout-cell}}
247 +**Check list:**
248 +
249 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!//
250 +
251 +* Open BS1  (//CrystalControl)//
252 +* Put collimator in (//CrystalControl)//
253 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)//
254 +* Open fast shutter (//CrystalControl)//
255 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)//
256 +* Close fast shutter (//CrystalControl)//
257 +
197 197  \\
259 +
260 +**Set run parameters and go 🏃💥**
261 +
262 +1. Set your desired No. of frames
263 +1. Match exposure time with chopper setting
264 +1. Check trigger setting and match to chopper setting
265 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it.
266 +1. To start the run, click "<Call>" next to //exposure time//
267 +
268 +\\
269 +
270 +(% style="color: rgb(153,51,102);" %)**//Current bug~://**
271 +
272 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>".
273 +
274 +
275 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with:
276 +
277 +(% class="code" %)
278 +(((
279 + cd /gpfs/current/raw/scan_frames
280 + watch "ls -lrt <run number>/ | tail"
281 +\\\\\\\\
282 +)))
283 +{{/layout-cell}}
284 +
285 +{{layout-cell}}
286 +(% class="wrapped relative-table" style="width: 100.0%;" %)
287 +|=(((
288 +Parameter
289 +)))|=(((
290 +explanation
291 +)))|=(% colspan="1" %)(((
292 +value
293 +)))
294 +|(((
295 +Images number
296 +)))|(((
297 +Set number of frames you want to collect
298 +)))|(% colspan="1" %)(((
299 +usually 100k - 200k, but adjust according to hitrate
300 +
301 +orientation: 10 % hitrate needs at least 100k images
302 +)))
303 +|(((
304 +exposure
305 +)))|(((
306 +exposure time of Eiger
307 +
308 +\\
309 +)))|(% colspan="1" %)(((
310 +chopper at 133 Hz → 3.7 ms
311 +
312 +chopper at 66 Hz   → 7.7 ms
313 +
314 +no chopper            → 7.7 ms
315 +
316 +----
317 +)))
318 +|(((
319 +run id
320 +)))|(((
321 +changes automatically
322 +)))|(% colspan="1" %)(((
323 +\\
324 +)))
325 +|(% colspan="1" %)(((
326 +Detector distance
327 +)))|(% colspan="1" %)(((
328 +current detector postion readout
329 +)))|(% colspan="1" %)(((
330 +\\
331 +)))
332 +|(% colspan="1" %)(((
333 +move_detector (distance)
334 +)))|(% colspan="1" %)(((
335 +Set detector distance
336 +)))|(% colspan="1" %)(((
337 +200.0 mm   (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>"
338 +)))
339 +|(% colspan="1" %)(((
340 +Diode voltage
341 +)))|(% colspan="1" %)(((
342 +read out of diode
343 +)))|(% colspan="1" %)(((
344 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 
345 +Call local contact
346 +**
347 +)))
348 +{{/layout-cell}}
349 +{{/layout-section}}
350 +
351 +{{layout-section ac:type="single"}}
352 +{{layout-cell}}
353 +----
354 +
355 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting ===
356 +
357 +* (((
358 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ====
359 +
360 +* Tape roll empty?
361 +* motor connected (icon green)?
362 +)))
363 +
364 +\\
365 +
366 +* (((
367 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ====
368 +
369 +* displayed in green=connected?
370 +* nozzle holder colliding somewhere?
371 +* motor limits reached? → position displayed in red
372 +)))
373 +
374 +\\
375 +
376 +* (((
377 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ====
378 +
379 +* channel turned on?
380 +* Sample empty?
381 +* Nozzle or lines clogged? → flush with water, change nozzle
382 +)))
383 +{{/layout-cell}}
384 +{{/layout-section}}
385 +{{/layout}}
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -235039461
1 +236824588
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/11/pages/235039461/14. Serial Crystallography: CFEL TapeDrive
1 +https://confluence.desy.de/spaces/11/pages/236824588/14. Serial Crystallography: CFEL TapeDrive