Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -79,14 +79,16 @@ 79 79 80 80 Be aware to which channel and nozzle line your sample is connected. 81 81 82 - Red → Channel 1, crystal line (nozzle capillary without marks) 82 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) 83 83 84 84 Green → Channel 2, substrate line (nozzle capillary is marked in black) 85 85 86 86 [[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 87 87 88 - \\88 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O. 89 89 90 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 91 + 90 90 \\ 91 91 92 92 === {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation ... ... @@ -113,9 +113,11 @@ 113 113 * ((( 114 114 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 115 115 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 116 -\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 117 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 118 118 119 + 120 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 121 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 122 + 119 119 (% class="wrapped" %) 120 120 |=((( 121 121 \\ ... ... @@ -164,12 +164,16 @@ 164 164 165 165 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 166 166 167 - \\171 +* The chiller circulates fluid through the gas nozzle. 168 168 169 169 \\ 170 170 175 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 176 + 171 171 \\ 172 172 179 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 180 + 173 173 \\ 174 174 175 175 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -182,7 +182,7 @@ 182 182 183 183 \\ 184 184 185 -=== ={{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** ====193 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** === 186 186 187 187 The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 188 188 ... ... @@ -189,15 +189,16 @@ 189 189 * Remove the (almost) empty feeder roll by pulling it upwards. 190 190 * Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 191 191 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 192 -* Cut the first cm of the new tape roll, directly be forethe black sticky part.193 -* Usethis stickypart to attach the end of the old tape to thenewroll.Place new rollon roll holder.194 -* Open magnetic tape stabilizer. 195 -* Start the tape (3mm/s). Once the connetion side (black sticky part)has arrived at the collector roll, stop the tape (0mm/s).196 -* Again, cut the tape directly in frontof theblackmark. Replace the the old roll with the **empty **one. Old roll can be discarded.197 -* Attach new tape to the empty roll by using theblackstickypart.200 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 201 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 202 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 203 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 204 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 205 +* Attach new tape to the empty roll by using some sticky tape. 198 198 * Close tape stabilizer. 207 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 199 199 200 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 209 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 201 201 ** 202 202 203 203 \\ ... ... @@ -204,8 +204,142 @@ 204 204 205 205 \\ 206 206 216 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 217 + 207 207 \\ 208 208 220 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** === 221 + 222 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 223 + 224 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 225 + password: //written on control laptop (changes every 6 months)// 226 + 227 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 228 + 209 209 \\ 210 210 231 +**Check list:** 232 + 233 +* Open BS1 (//CrystalControl)// 234 +* Put collimator in (//CrystalControl)// 235 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 236 +* Open fast shutter (//CrystalControl)// 237 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 238 +* Close fast shutter (//CrystalControl)// 239 + 211 211 \\ 241 + 242 +**Start run in kamzik 243 +** 244 + 245 +Click "Start" icon in kamzik. 246 + 247 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 248 + 249 +|=((( 250 +Parameter 251 +)))|=((( 252 +explanation 253 +)))|=(% colspan="1" %)((( 254 +value 255 +))) 256 +|((( 257 +Images number 258 +)))|((( 259 +Set number of frames you want to collect 260 +)))|(% colspan="1" %)((( 261 +usually 100k - 200k, but adjust according to hitrate 262 + 263 +orientation: 10 % hitrate needs at least 100k images 264 +))) 265 +|((( 266 +exposure 267 +)))|((( 268 +exposure time of Eiger 269 + 270 +\\ 271 +)))|(% colspan="1" %)((( 272 +chopper at 133 Hz → 3.7 ms 273 + 274 +chopper at 66 Hz → 7.7 ms 275 + 276 +no chopper → 7.7 ms 277 + 278 +---- 279 +))) 280 +|((( 281 +run id 282 +)))|((( 283 +changes automatically 284 +)))|(% colspan="1" %)((( 285 +\\ 286 +))) 287 +|(% colspan="1" %)((( 288 +Detector distance 289 +)))|(% colspan="1" %)((( 290 +current detector postion readout 291 +)))|(% colspan="1" %)((( 292 +\\ 293 +))) 294 +|(% colspan="1" %)((( 295 +move_detector (distance) 296 +)))|(% colspan="1" %)((( 297 +Set detector distance 298 +)))|(% colspan="1" %)((( 299 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 300 +))) 301 +|(% colspan="1" %)((( 302 +Diode voltage 303 +)))|(% colspan="1" %)((( 304 +read out of diode 305 +)))|(% colspan="1" %)((( 306 +**~~ 0 !!! higher values indicate missaligned beam stop!!!** 307 +))) 308 + 309 +---- 310 + 311 +(% class="task-list" %) 312 +((( 313 +{{task reference="/Tasks/Task_6" status="InProgress"}} 314 +Set your desired No. of frames 315 +{{/task}} 316 + 317 +{{task reference="/Tasks/Task_7" status="InProgress"}} 318 +Match exposure time with chopper setting 319 +{{/task}} 320 + 321 +{{task reference="/Tasks/Task_8" status="InProgress"}} 322 +Check trigger setting and match to chopper setting 323 +{{/task}} 324 + 325 +{{task reference="/Tasks/Task_9" status="InProgress"}} 326 +Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 327 +{{/task}} 328 + 329 +{{task reference="/Tasks/Task_10" status="InProgress"}} 330 +To start the run, click "<Call>" next to //exposure time// 331 +{{/task}} 332 +))) 333 + 334 +---- 335 + 336 +\\ 337 + 338 +\\ 339 + 340 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 341 + 342 +* ((( 343 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 344 +))) 345 +* ((( 346 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 347 +))) 348 +* ((( 349 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 350 +))) 351 + 352 +\\ 353 + 354 +\\
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23 50415121 +236824562 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23 5041512/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824562/14. Serial Crystallography: CFEL TapeDrive