Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,3 +1,6 @@ 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 1 1 2 2 3 3 {{toc/}} ... ... @@ -79,14 +79,16 @@ 79 79 80 80 Be aware to which channel and nozzle line your sample is connected. 81 81 82 - Red → Channel 1, crystal line (nozzle capillary without marks) 85 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) 83 83 84 84 Green → Channel 2, substrate line (nozzle capillary is marked in black) 85 85 86 86 [[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 87 87 88 - \\91 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O. 89 89 93 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 94 + 90 90 \\ 91 91 92 92 === {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation ... ... @@ -113,9 +113,11 @@ 113 113 * ((( 114 114 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 115 115 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 116 -\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 117 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 118 118 122 + 123 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 124 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 125 + 119 119 (% class="wrapped" %) 120 120 |=((( 121 121 \\ ... ... @@ -164,12 +164,16 @@ 164 164 165 165 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 166 166 167 - \\174 +* The chiller circulates fluid through the gas nozzle. 168 168 169 169 \\ 170 170 178 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 179 + 171 171 \\ 172 172 182 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 183 + 173 173 \\ 174 174 175 175 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -189,15 +189,16 @@ 189 189 * Remove the (almost) empty feeder roll by pulling it upwards. 190 190 * Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 191 191 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 192 -* Cut the first cm of the new tape roll, directly be forethe black sticky part.193 -* Usethis stickypart to attach the end of the old tape to thenewroll.Place new rollon roll holder.194 -* Open magnetic tape stabilizer. 195 -* Start the tape (3mm/s). Once the connetion side (black sticky part)has arrived at the collector roll, stop the tape (0mm/s).196 -* Again, cut the tape directly in frontof theblackmark. Replace the the old roll with the **empty **one. Old roll can be discarded.197 -* Attach new tape to the empty roll by using theblackstickypart.203 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 204 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 205 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 206 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 207 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 208 +* Attach new tape to the empty roll by using some sticky tape. 198 198 * Close tape stabilizer. 210 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 199 199 200 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 212 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 201 201 ** 202 202 203 203 \\ ... ... @@ -204,8 +204,131 @@ 204 204 205 205 \\ 206 206 219 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 220 + 207 207 \\ 208 208 223 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** === 224 + 225 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 226 + 227 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 228 + password: //written on control laptop (changes every 6 months)// 229 + 230 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 231 + 209 209 \\ 210 210 234 +**Check list:** 235 + 236 +* Open BS1 (//CrystalControl)// 237 +* Put collimator in (//CrystalControl)// 238 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 239 +* Open fast shutter (//CrystalControl)// 240 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 241 +* Close fast shutter (//CrystalControl)// 242 + 211 211 \\ 244 + 245 +**Start run in kamzik 246 +** 247 + 248 +Click "Start" icon in kamzik. 249 + 250 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 251 + 252 +---- 253 +{{/layout-cell}} 254 +{{/layout-section}} 255 + 256 +{{layout-section ac:type="two_equal"}} 257 +{{layout-cell}} 258 +\\ 259 + 260 +1. Set your desired No. of frames 261 +1. Match exposure time with chopper setting 262 +1. Check trigger setting and match to chopper setting 263 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 264 +1. To start the run, click "<Call>" next to //exposure time// 265 +{{/layout-cell}} 266 + 267 +{{layout-cell}} 268 +(% class="wrapped" %) 269 +|=((( 270 +Parameter 271 +)))|=((( 272 +explanation 273 +)))|=(% colspan="1" %)((( 274 +value 275 +))) 276 +|((( 277 +Images number 278 +)))|((( 279 +Set number of frames you want to collect 280 +)))|(% colspan="1" %)((( 281 +usually 100k - 200k, but adjust according to hitrate 282 + 283 +orientation: 10 % hitrate needs at least 100k images 284 +))) 285 +|((( 286 +exposure 287 +)))|((( 288 +exposure time of Eiger 289 + 290 +\\ 291 +)))|(% colspan="1" %)((( 292 +chopper at 133 Hz → 3.7 ms 293 + 294 +chopper at 66 Hz → 7.7 ms 295 + 296 +no chopper → 7.7 ms 297 + 298 +---- 299 +))) 300 +|((( 301 +run id 302 +)))|((( 303 +changes automatically 304 +)))|(% colspan="1" %)((( 305 +\\ 306 +))) 307 +|(% colspan="1" %)((( 308 +Detector distance 309 +)))|(% colspan="1" %)((( 310 +current detector postion readout 311 +)))|(% colspan="1" %)((( 312 +\\ 313 +))) 314 +|(% colspan="1" %)((( 315 +move_detector (distance) 316 +)))|(% colspan="1" %)((( 317 +Set detector distance 318 +)))|(% colspan="1" %)((( 319 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 320 +))) 321 +|(% colspan="1" %)((( 322 +Diode voltage 323 +)))|(% colspan="1" %)((( 324 +read out of diode 325 +)))|(% colspan="1" %)((( 326 +**~~ 0 !!! higher values indicate missaligned beam stop!!!** 327 +))) 328 +{{/layout-cell}} 329 +{{/layout-section}} 330 + 331 +{{layout-section ac:type="single"}} 332 +{{layout-cell}} 333 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 334 + 335 +* ((( 336 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 337 +))) 338 +* ((( 339 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 340 +))) 341 +* ((( 342 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 343 +))) 344 +{{/layout-cell}} 345 +{{/layout-section}} 346 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23 50415181 +236824573 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23 5041518/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824573/14. Serial Crystallography: CFEL TapeDrive