Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,3 +1,6 @@ 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 1 1 2 2 3 3 {{toc/}} ... ... @@ -79,14 +79,16 @@ 79 79 80 80 Be aware to which channel and nozzle line your sample is connected. 81 81 82 - Red → Channel 1, crystal line (nozzle capillary without marks) 85 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) 83 83 84 84 Green → Channel 2, substrate line (nozzle capillary is marked in black) 85 85 86 86 [[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 87 87 88 - \\91 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O. 89 89 93 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 94 + 90 90 \\ 91 91 92 92 === {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation ... ... @@ -113,9 +113,11 @@ 113 113 * ((( 114 114 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 115 115 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 116 -\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 117 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 118 118 122 + 123 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 124 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 125 + 119 119 (% class="wrapped" %) 120 120 |=((( 121 121 \\ ... ... @@ -164,12 +164,16 @@ 164 164 165 165 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 166 166 167 - \\174 +* The chiller circulates fluid through the gas nozzle. 168 168 169 169 \\ 170 170 178 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 179 + 171 171 \\ 172 172 182 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 183 + 173 173 \\ 174 174 175 175 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -189,15 +189,16 @@ 189 189 * Remove the (almost) empty feeder roll by pulling it upwards. 190 190 * Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 191 191 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 192 -* Cut the first cm of the new tape roll, directly be forethe black sticky part.193 -* Usethis stickypart to attach the end of the old tape to thenewroll.Place new rollon roll holder.194 -* Open magnetic tape stabilizer. 195 -* Start the tape (3mm/s). Once the connetion side (black sticky part)has arrived at the collector roll, stop the tape (0mm/s).196 -* Again, cut the tape directly in frontof theblackmark. Replace the the old roll with the **empty **one. Old roll can be discarded.197 -* Attach new tape to the empty roll by using theblackstickypart.203 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 204 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 205 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 206 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 207 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 208 +* Attach new tape to the empty roll by using some sticky tape. 198 198 * Close tape stabilizer. 210 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 199 199 200 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 212 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 201 201 ** 202 202 203 203 \\ ... ... @@ -204,8 +204,150 @@ 204 204 205 205 \\ 206 206 219 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 220 + 207 207 \\ 208 208 223 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** === 224 + 225 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 226 + 227 +(% class="code" %) 228 +((( 229 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 230 + password: written on control laptop (changes every 6 months) 231 +))) 232 + 233 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 234 + 209 209 \\ 210 210 237 +Click "Start" icon in kamzik. 238 + 239 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 240 + 241 +---- 242 +{{/layout-cell}} 243 +{{/layout-section}} 244 + 245 +{{layout-section ac:type="two_equal"}} 246 +{{layout-cell}} 247 +**Check list:** 248 + 249 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 250 + 251 +* Open BS1 (//CrystalControl)// 252 +* Put collimator in (//CrystalControl)// 253 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 254 +* Open fast shutter (//CrystalControl)// 255 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 256 +* Close fast shutter (//CrystalControl)// 257 + 211 211 \\ 259 + 260 +**Set run parameters and go 🏃💥** 261 + 262 +1. Set your desired No. of frames 263 +1. Match exposure time with chopper setting 264 +1. Check trigger setting and match to chopper setting 265 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 266 +1. To start the run, click "<Call>" next to //exposure time// 267 + 268 +\\ 269 + 270 +(% style="color: rgb(153,51,102);" %)**//Current bug~://** 271 + 272 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 273 + 274 + 275 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 276 + 277 +(% class="code" %) 278 +((( 279 + cd /gpfs/current/raw/scan_frames 280 + watch "ls -lrt <run number>/ | tail" 281 +))) 282 +{{/layout-cell}} 283 + 284 +{{layout-cell}} 285 +(% class="wrapped relative-table" style="width: 100.0%;" %) 286 +|=((( 287 +Parameter 288 +)))|=((( 289 +explanation 290 +)))|=(% colspan="1" %)((( 291 +value 292 +))) 293 +|((( 294 +Images number 295 +)))|((( 296 +Set number of frames you want to collect 297 +)))|(% colspan="1" %)((( 298 +usually 100k - 200k, but adjust according to hitrate 299 + 300 +orientation: 10 % hitrate needs at least 100k images 301 +))) 302 +|((( 303 +exposure 304 +)))|((( 305 +exposure time of Eiger 306 + 307 +\\ 308 +)))|(% colspan="1" %)((( 309 +chopper at 133 Hz → 3.7 ms 310 + 311 +chopper at 66 Hz → 7.7 ms 312 + 313 +no chopper → 7.7 ms 314 + 315 +---- 316 +))) 317 +|((( 318 +run id 319 +)))|((( 320 +changes automatically 321 +)))|(% colspan="1" %)((( 322 +\\ 323 +))) 324 +|(% colspan="1" %)((( 325 +Detector distance 326 +)))|(% colspan="1" %)((( 327 +current detector postion readout 328 +)))|(% colspan="1" %)((( 329 +\\ 330 +))) 331 +|(% colspan="1" %)((( 332 +move_detector (distance) 333 +)))|(% colspan="1" %)((( 334 +Set detector distance 335 +)))|(% colspan="1" %)((( 336 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 337 +))) 338 +|(% colspan="1" %)((( 339 +Diode voltage 340 +)))|(% colspan="1" %)((( 341 +read out of diode 342 +)))|(% colspan="1" %)((( 343 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 344 +Call local contact 345 +** 346 +))) 347 +{{/layout-cell}} 348 +{{/layout-section}} 349 + 350 +{{layout-section ac:type="single"}} 351 +{{layout-cell}} 352 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 353 + 354 +* ((( 355 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 356 +))) 357 +* ((( 358 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 359 +))) 360 +* ((( 361 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 362 +))) 363 +{{/layout-cell}} 364 +{{/layout-section}} 365 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23 50415181 +236824574 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23 5041518/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824574/14. Serial Crystallography: CFEL TapeDrive