Summary

Details

Page properties
Content
... ... @@ -1,7 +1,6 @@
1 -
2 -
3 -{{toc/}}
4 -
1 +{{layout}}
2 +{{layout-section ac:type="single"}}
3 +{{layout-cell}}
5 5  [[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]]
6 6  
7 7  \\
... ... @@ -79,7 +79,7 @@
79 79  
80 80  Be aware to which channel and nozzle line your sample is connected.
81 81  
82 - Red → Channel 1, crystal line (nozzle capillary without marks)
81 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks)
83 83  
84 84   Green → Channel 2, substrate line (nozzle capillary is marked in black)
85 85  
... ... @@ -115,10 +115,11 @@
115 115  * (((
116 116  The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully.
117 117  The absolute position is **not calibrated** and therefore changes after each restart of kamzik.
118 -\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%)
119 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments.
120 120  
121 -(% class="wrapped" %)
118 +
119 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%)
120 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments.
121 +
122 122  |=(((
123 123  \\
124 124  )))|=(((
... ... @@ -166,12 +166,16 @@
166 166  
167 167  ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ====
168 168  
169 -\\
169 +* The chiller circulates fluid through the gas nozzle.
170 170  
171 171  \\
172 172  
173 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ====
174 +
173 173  \\
174 174  
177 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ====
178 +
175 175  \\
176 176  
177 177  Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
... ... @@ -191,15 +191,16 @@
191 191  * Remove the (almost) empty feeder roll by pulling it upwards.
192 192  * Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!**
193 193  * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm**
194 -* Cut the first cm of the new tape roll, directly before the black sticky part.
195 -* Use this sticky part to attach the end of the old tape to the new roll. Place new roll on roll holder.
196 -* Open magnetic tape stabilizer.
197 -* Start the tape (3mm/s). Once the connetion side (black sticky part) has arrived at the collector roll, stop the tape (0mm/s).
198 -* Again, cut the tape directly in front of the black mark. Replace the the old roll with the **empty **one. Old roll can be discarded.
199 -* Attach new tape to the empty roll by using the black sticky part.
198 +* Cut the first cm of the new tape roll, directly behind the black sticky part.
199 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll.
200 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!//
201 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s).
202 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded.
203 +* Attach new tape to the empty roll by using some sticky tape.
200 200  * Close tape stabilizer.
205 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape".
201 201  
202 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]]
207 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]]
203 203  **
204 204  
205 205  \\
... ... @@ -206,26 +206,212 @@
206 206  
207 207  \\
208 208  
209 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}14.6 Nozzle exchange ===
214 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** ===
215 +{{/layout-cell}}
216 +{{/layout-section}}
210 210  
218 +{{layout-section ac:type="single"}}
219 +{{layout-cell}}
220 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Chopper"/}}**14.7 Chopper** ===
221 +
222 +start chopper gui from terminal:
223 +
224 +(% class="code" %)
225 +(((
226 + cd /gpfs/local/shared/ChopperControl
227 +)))
228 +
229 +(% class="code" %)
230 +(((
231 + python chopperControl.py
232 +)))
233 +{{/layout-cell}}
234 +{{/layout-section}}
235 +
236 +{{layout-section ac:type="two_equal"}}
237 +{{layout-cell}}
238 + [[image:attach:20211212_233140.jpg||height="250"]]
239 +{{/layout-cell}}
240 +
241 +{{layout-cell}}
242 +**Chopper → no Chopper**
243 +
244 +* decrease frequency by max. 10 Hz steps\\
245 +** click arrow down 10x, "Set", arrow down 10x, "Set", ....
246 +* at frequency = 10 Hz, click "Stop"
247 +* set "Hole" to <none> (% style="color: rgb(255,0,0);" %)//Takes some minutes//
248 +
249 +(% style="color: rgb(0,0,0);" %)**no Chopper → Chopper**
250 +
251 +* (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes//
252 +* (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps
253 +** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", .....
254 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms//
255 +{{/layout-cell}}
256 +{{/layout-section}}
257 +
258 +{{layout-section ac:type="single"}}
259 +{{layout-cell}}
260 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Datacollection"/}}**14.8 Data collection** ===
261 +
262 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
263 +
264 +(% class="code" %)
265 +(((
266 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611
267 + password: written on control laptop (changes every 6 months)
268 +)))
269 +
270 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password//
271 +
211 211  \\
212 212  
213 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}14.7 Data collection ===
274 +Click "Start" icon in kamzik.
214 214  
276 +[[image:attach:kamzik_run-tile.jpg||height="400"]]
277 +
278 +----
279 +{{/layout-cell}}
280 +{{/layout-section}}
281 +
282 +{{layout-section ac:type="two_equal"}}
283 +{{layout-cell}}
284 +**Check list:**
285 +
286 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!//
287 +
288 +* Open BS1  (//CrystalControl)//
289 +* Put collimator in (//CrystalControl)//
290 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)//
291 +* Open fast shutter (//CrystalControl)//
292 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)//
293 +* Close fast shutter (//CrystalControl)//
294 +
215 215  \\
216 216  
217 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting ===
297 +**Set run parameters and go 🏃💥**
218 218  
299 +1. Set your desired No. of frames
300 +1. Match exposure time with chopper setting
301 +1. Check trigger setting and match to chopper setting
302 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it.
303 +1. To start the run, click "<Call>" next to //exposure time//
304 +
305 +\\
306 +
307 +(% style="color: rgb(153,51,102);" %)**//Current bug~://**
308 +
309 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>".
310 +
311 +
312 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with:
313 +
314 +(% class="code" %)
315 +(((
316 + cd /gpfs/current/raw/scan_frames
317 + watch "ls -lrt <run number>/ | tail"
318 +\\\\\\\\
319 +)))
320 +{{/layout-cell}}
321 +
322 +{{layout-cell}}
323 +(% class="wrapped relative-table" style="width: 100.0%;" %)
324 +|=(((
325 +Parameter
326 +)))|=(((
327 +explanation
328 +)))|=(% colspan="1" %)(((
329 +value
330 +)))
331 +|(((
332 +Images number
333 +)))|(((
334 +Set number of frames you want to collect
335 +)))|(% colspan="1" %)(((
336 +usually 100k - 200k, but adjust according to hitrate
337 +
338 +orientation: 10 % hitrate needs at least 100k images
339 +)))
340 +|(((
341 +exposure
342 +)))|(((
343 +exposure time of Eiger
344 +
345 +\\
346 +)))|(% colspan="1" %)(((
347 +chopper at 133 Hz → 3.7 ms
348 +
349 +chopper at 66 Hz   → 7.7 ms
350 +
351 +no chopper            → 7.7 ms
352 +
353 +----
354 +)))
355 +|(((
356 +run id
357 +)))|(((
358 +changes automatically
359 +)))|(% colspan="1" %)(((
360 +\\
361 +)))
362 +|(% colspan="1" %)(((
363 +Detector distance
364 +)))|(% colspan="1" %)(((
365 +current detector postion readout
366 +)))|(% colspan="1" %)(((
367 +\\
368 +)))
369 +|(% colspan="1" %)(((
370 +move_detector (distance)
371 +)))|(% colspan="1" %)(((
372 +Set detector distance
373 +)))|(% colspan="1" %)(((
374 +200.0 mm   (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>"
375 +)))
376 +|(% colspan="1" %)(((
377 +Diode voltage
378 +)))|(% colspan="1" %)(((
379 +read out of diode
380 +)))|(% colspan="1" %)(((
381 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 
382 +Call local contact
383 +**
384 +)))
385 +{{/layout-cell}}
386 +{{/layout-section}}
387 +
388 +{{layout-section ac:type="single"}}
389 +{{layout-cell}}
390 +----
391 +
392 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.9Troubleshooting"/}}14.9 Troubleshooting ===
393 +
219 219  * (((
220 220  ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ====
396 +
397 +* Tape roll empty?
398 +* motor connected (icon green)?
221 221  )))
400 +
401 +\\
402 +
222 222  * (((
223 223  ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ====
405 +
406 +* displayed in green=connected?
407 +* nozzle holder colliding somewhere?
408 +* motor limits reached? → position displayed in red
224 224  )))
225 -* (((
226 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ====
227 -)))
228 228  
229 229  \\
230 230  
231 -\\
413 +* (((
414 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ====
415 +
416 +* channel turned on?
417 +* Sample empty?
418 +* Nozzle or lines clogged? → flush with water, change nozzle
419 +)))
420 +{{/layout-cell}}
421 +{{/layout-section}}
422 +{{/layout}}
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -236815627
1 +236824590
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/11/pages/236815627/14. Serial Crystallography: CFEL TapeDrive
1 +https://confluence.desy.de/spaces/11/pages/236824590/14. Serial Crystallography: CFEL TapeDrive