... ... @@ -1,3 +1,387 @@
1 -**14.1 Revert from Crystallography to TapeDrive (P11 staff)**
1 +{{layout}}
2 +{{layout-section ac:type="single"}}
3 +{{layout-cell}}
4 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="250"]]
2 2  
3 3  \\
7 +
8 +{{toc minLevel="2"/}}
9 +
10 +\\
11 +
12 +----
13 +
14 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** ==
15 +
16 +suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.
17 +
18 +Preparation:
19 +
20 +* filter through 30 µm cell filter (green) into Eppendorf or Falcon (original!) tube
21 +
22 +[[image:attach:20211201_095534.jpg||height="250"]]
23 +
24 +\\
25 +
26 +----
27 +
28 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}**14.2 Connecting sample to ElveFlow, sample exchange
29 +** ==
30 +
31 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!**
32 +
33 +Be aware to which channel and nozzle line your sample is connected.
34 +
35 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks)
36 +
37 + Green → Channel 2, substrate line (nozzle capillary is marked in black)
38 +
39 +[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]]
40 +
41 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O.
42 +
43 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]]
44 +
45 +\\
46 +
47 +----
48 +
49 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}**14.3 TapeDrive operation
50 +** ==
51 +
52 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window.
53 +Now start the client. Same thing, a terminal will open, shortly after a small window.
54 +
55 +Click 'Devices' in the **client session** to open the control window.
56 +[[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]]
57 +
58 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ====
59 +
60 +* Click on the 'main tape' icon
61 +* Change the velocity by typing anything from **0.3-3.0 mm/s**
62 +* Common velocity is 1.0-1.5 mm/s
63 +* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point.
64 +\\
65 +* [[image:attach:kamzik_tape.PNG||height="400"]]
66 +
67 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ====
68 +
69 +* Click an the 'nozzle' icon.
70 +* (((
71 +The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully.
72 +The absolute position is **not calibrated** and therefore changes after each restart of kamzik.
73 +
74 +
75 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%)
76 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments.
77 +
78 +(% class="wrapped" %)
79 +|=(((
80 +\\
81 +)))|=(((
82 +direction
83 +)))|=(((
84 +recommended step size
85 +for visual adjustment
86 +)))|=(% colspan="1" %)(((
87 +recommended step size
88 +during data collection
89 +)))
90 +|(((
91 ++x
92 +)))|(((
93 +away from X-ray interaction point
94 +)))|(((
95 +1.0 - 0.5 mm
96 +)))|(% colspan="1" %)(((
97 +0.1 - 0.2 mm
98 +)))
99 +|(((
100 ++y
101 +)))|(((
102 +up
103 +)))|(((
104 +1.0 - 0.5 mm
105 +)))|(% colspan="1" %)(((
106 +0.1 - 0.2 mm
107 +)))
108 +|(((
109 ++z
110 +)))|(((
111 +towards detector tower, away from tape
112 +)))|(((
113 +0.5 - 0.2 mm
114 +)))|(% colspan="1" %)(((
115 +0.1 - 0.2 mm
116 +be careful with -z, tape could be pushed out of focus
117 +)))
118 +
119 +**
120 +\\**
121 +)))
122 +* [[image:attach:kamzik_nozzle.PNG||height="400"]]
123 +
124 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ====
125 +
126 +* The chiller circulates fluid through the gas nozzle.
127 +
128 +\\
129 +
130 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ====
131 +
132 +\\
133 +
134 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ====
135 +
136 +\\
137 +
138 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
139 +
140 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611
141 + password: //written on control laptop (changes every 6 months)
142 +//
143 +
144 +\\
145 +
146 +\\
147 +
148 +----
149 +
150 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}}**14.4 Tape roll exchange** ==
151 +
152 +The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s).
153 +
154 +* Remove the (almost) empty feeder roll by pulling it upwards.
155 +* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!**
156 +* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm**
157 +* Cut the first cm of the new tape roll, directly behind the black sticky part.
158 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll.
159 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!//
160 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s).
161 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded.
162 +* Attach new tape to the empty roll by using some sticky tape.
163 +* Close tape stabilizer.
164 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape".
165 +
166 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]]
167 +**
168 +
169 +\\
170 +
171 +\\
172 +
173 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-"/}}**
174 +** ===
175 +{{/layout-cell}}
176 +{{/layout-section}}
177 +
178 +{{layout-section ac:type="single"}}
179 +{{layout-cell}}
180 +----
181 +
182 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}}**14.5 Chopper** ==
183 +
184 +start chopper gui from terminal:
185 +
186 +(% class="code" %)
187 +(((
188 + cd /gpfs/local/shared/ChopperControl
189 +)))
190 +
191 +(% class="code" %)
192 +(((
193 + python chopperControl.py
194 +\\\\
195 +)))
196 +{{/layout-cell}}
197 +{{/layout-section}}
198 +
199 +{{layout-section ac:type="two_equal"}}
200 +{{layout-cell}}
201 + [[image:attach:20211212_233140.jpg||height="250"]]
202 +{{/layout-cell}}
203 +
204 +{{layout-cell}}
205 +**Chopper → no Chopper**
206 +
207 +* decrease frequency by max. 10 Hz steps\\
208 +** click arrow down 10x, "Set", arrow down 10x, "Set", ....
209 +* at frequency = 10 Hz, click "Stop"
210 +* set "Hole" to <none> (% style="color: rgb(255,0,0);" %)//Takes some minutes//
211 +
212 +(% style="color: rgb(0,0,0);" %)**no Chopper → Chopper**
213 +
214 +* (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes//
215 +* (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps
216 +** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", .....
217 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms//
218 +{{/layout-cell}}
219 +{{/layout-section}}
220 +
221 +{{layout-section ac:type="single"}}
222 +{{layout-cell}}
223 +----
224 +
225 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** ==
226 +
227 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
228 +
229 +(% class="code" %)
230 +(((
231 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611
232 + password: written on control laptop (changes every 6 months)
233 +)))
234 +
235 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password//
236 +
237 +\\
238 +
239 +Click "Start" icon in kamzik.
240 +
241 +[[image:attach:kamzik_run-tile.jpg||height="400"]]
242 +
243 +----
244 +{{/layout-cell}}
245 +{{/layout-section}}
246 +
247 +{{layout-section ac:type="two_equal"}}
248 +{{layout-cell}}
249 +**Check list:**
250 +
251 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!//
252 +
253 +* Open BS1  (//CrystalControl)//
254 +* Put collimator in (//CrystalControl)//
255 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)//
256 +* Open fast shutter (//CrystalControl)//
257 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)//
258 +* Close fast shutter (//CrystalControl)//
259 +
260 +\\
261 +
262 +**Set run parameters and go 🏃💥**
263 +
264 +1. Set your desired No. of frames
265 +1. Match exposure time with chopper setting
266 +1. Check trigger setting and match to chopper setting
267 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it.
268 +1. To start the run, click "<Call>" next to //exposure time//
269 +
270 +\\
271 +
272 +(% style="color: rgb(153,51,102);" %)**//Current bug~://**
273 +
274 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>".
275 +
276 +
277 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with:
278 +
279 +(% class="code" %)
280 +(((
281 + cd /gpfs/current/raw/scan_frames
282 + watch "ls -lrt <run number>/ | tail"
283 +\\\\\\\\
284 +)))
285 +{{/layout-cell}}
286 +
287 +{{layout-cell}}
288 +(% class="wrapped relative-table" style="width: 100.0%;" %)
289 +|=(((
290 +Parameter
291 +)))|=(((
292 +explanation
293 +)))|=(% colspan="1" %)(((
294 +value
295 +)))
296 +|(((
297 +Images number
298 +)))|(((
299 +Set number of frames you want to collect
300 +)))|(% colspan="1" %)(((
301 +usually 100k - 200k, but adjust according to hitrate
302 +
303 +orientation: 10 % hitrate needs at least 100k images
304 +)))
305 +|(((
306 +exposure
307 +)))|(((
308 +exposure time of Eiger
309 +
310 +\\
311 +)))|(% colspan="1" %)(((
312 +chopper at 133 Hz → 3.7 ms
313 +
314 +chopper at 66 Hz   → 7.7 ms
315 +
316 +no chopper            → 7.7 ms
317 +
318 +----
319 +)))
320 +|(((
321 +run id
322 +)))|(((
323 +changes automatically
324 +)))|(% colspan="1" %)(((
325 +\\
326 +)))
327 +|(% colspan="1" %)(((
328 +Detector distance
329 +)))|(% colspan="1" %)(((
330 +current detector postion readout
331 +)))|(% colspan="1" %)(((
332 +\\
333 +)))
334 +|(% colspan="1" %)(((
335 +move_detector (distance)
336 +)))|(% colspan="1" %)(((
337 +Set detector distance
338 +)))|(% colspan="1" %)(((
339 +200.0 mm   (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>"
340 +)))
341 +|(% colspan="1" %)(((
342 +Diode voltage
343 +)))|(% colspan="1" %)(((
344 +read out of diode
345 +)))|(% colspan="1" %)(((
346 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 
347 +Call local contact
348 +**
349 +)))
350 +{{/layout-cell}}
351 +{{/layout-section}}
352 +
353 +{{layout-section ac:type="single"}}
354 +{{layout-cell}}
355 +----
356 +
357 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Troubleshooting"/}}**14.7 Troubleshooting** ==
358 +
359 +* (((
360 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ====
361 +
362 +* Tape roll empty?
363 +* motor connected (icon green)?
364 +)))
365 +
366 +\\
367 +
368 +* (((
369 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ====
370 +
371 +* displayed in green=connected?
372 +* nozzle holder colliding somewhere?
373 +* motor limits reached? → position displayed in red
374 +)))
375 +
376 +\\
377 +
378 +* (((
379 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ====
380 +
381 +* channel turned on?
382 +* Sample empty?
383 +* Nozzle or lines clogged? → flush with water, change nozzle
384 +)))
385 +{{/layout-cell}}
386 +{{/layout-section}}
387 +{{/layout}}
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -235032181
1 +236824604
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/11/pages/235032181/14. Serial Crystallography: CFEL TapeDrive
1 +https://confluence.desy.de/spaces/11/pages/236824604/14. Serial Crystallography: CFEL TapeDrive