Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,3 +1,387 @@ 1 -**14.1 Revert from Crystallography to TapeDrive (P11 staff)** 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 4 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="250"]] 2 2 3 3 \\ 7 + 8 +{{toc minLevel="2"/}} 9 + 10 +\\ 11 + 12 +---- 13 + 14 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** == 15 + 16 +suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 17 + 18 +Preparation: 19 + 20 +* filter through 30 µm cell filter (green) into Eppendorf or Falcon (original!) tube 21 + 22 +[[image:attach:20211201_095534.jpg||height="250"]] 23 + 24 +\\ 25 + 26 +---- 27 + 28 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}**14.2 Connecting sample to ElveFlow, sample exchange 29 +** == 30 + 31 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 32 + 33 +Be aware to which channel and nozzle line your sample is connected. 34 + 35 + Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) 36 + 37 + Green → Channel 2, substrate line (nozzle capillary is marked in black) 38 + 39 +[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 40 + 41 +After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O. 42 + 43 +[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 44 + 45 +\\ 46 + 47 +---- 48 + 49 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}**14.3 TapeDrive operation 50 +** == 51 + 52 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 53 +Now start the client. Same thing, a terminal will open, shortly after a small window. 54 + 55 +Click 'Devices' in the **client session** to open the control window. 56 +[[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 57 + 58 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ==== 59 + 60 +* Click on the 'main tape' icon 61 +* Change the velocity by typing anything from **0.3-3.0 mm/s** 62 +* Common velocity is 1.0-1.5 mm/s 63 +* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 64 +\\ 65 +* [[image:attach:kamzik_tape.PNG||height="400"]] 66 + 67 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 68 + 69 +* Click an the 'nozzle' icon. 70 +* ((( 71 +The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 72 +The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 73 + 74 + 75 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 76 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 77 + 78 +(% class="wrapped" %) 79 +|=((( 80 +\\ 81 +)))|=((( 82 +direction 83 +)))|=((( 84 +recommended step size 85 +for visual adjustment 86 +)))|=(% colspan="1" %)((( 87 +recommended step size 88 +during data collection 89 +))) 90 +|((( 91 ++x 92 +)))|((( 93 +away from X-ray interaction point 94 +)))|((( 95 +1.0 - 0.5 mm 96 +)))|(% colspan="1" %)((( 97 +0.1 - 0.2 mm 98 +))) 99 +|((( 100 ++y 101 +)))|((( 102 +up 103 +)))|((( 104 +1.0 - 0.5 mm 105 +)))|(% colspan="1" %)((( 106 +0.1 - 0.2 mm 107 +))) 108 +|((( 109 ++z 110 +)))|((( 111 +towards detector tower, away from tape 112 +)))|((( 113 +0.5 - 0.2 mm 114 +)))|(% colspan="1" %)((( 115 +0.1 - 0.2 mm 116 +be careful with -z, tape could be pushed out of focus 117 +))) 118 + 119 +** 120 +\\** 121 +))) 122 +* [[image:attach:kamzik_nozzle.PNG||height="400"]] 123 + 124 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 125 + 126 +* The chiller circulates fluid through the gas nozzle. 127 + 128 +\\ 129 + 130 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 131 + 132 +\\ 133 + 134 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 135 + 136 +\\ 137 + 138 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 139 + 140 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 141 + password: //written on control laptop (changes every 6 months) 142 +// 143 + 144 +\\ 145 + 146 +\\ 147 + 148 +---- 149 + 150 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}}**14.4 Tape roll exchange** == 151 + 152 +The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 153 + 154 +* Remove the (almost) empty feeder roll by pulling it upwards. 155 +* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 156 +* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 157 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 158 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 159 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 160 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 161 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 162 +* Attach new tape to the empty roll by using some sticky tape. 163 +* Close tape stabilizer. 164 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 165 + 166 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 167 +** 168 + 169 +\\ 170 + 171 +\\ 172 + 173 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-"/}}** 174 +** === 175 +{{/layout-cell}} 176 +{{/layout-section}} 177 + 178 +{{layout-section ac:type="single"}} 179 +{{layout-cell}} 180 +---- 181 + 182 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}}**14.5 Chopper** == 183 + 184 +start chopper gui from terminal: 185 + 186 +(% class="code" %) 187 +((( 188 + cd /gpfs/local/shared/ChopperControl 189 +))) 190 + 191 +(% class="code" %) 192 +((( 193 + python chopperControl.py 194 +\\\\ 195 +))) 196 +{{/layout-cell}} 197 +{{/layout-section}} 198 + 199 +{{layout-section ac:type="two_equal"}} 200 +{{layout-cell}} 201 + [[image:attach:20211212_233140.jpg||height="250"]] 202 +{{/layout-cell}} 203 + 204 +{{layout-cell}} 205 +**Chopper → no Chopper** 206 + 207 +* decrease frequency by max. 10 Hz steps\\ 208 +** click arrow down 10x, "Set", arrow down 10x, "Set", .... 209 +* at frequency = 10 Hz, click "Stop" 210 +* set "Hole" to <none> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 211 + 212 +(% style="color: rgb(0,0,0);" %)**no Chopper → Chopper** 213 + 214 +* (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 215 +* (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 216 +** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 217 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 218 +{{/layout-cell}} 219 +{{/layout-section}} 220 + 221 +{{layout-section ac:type="single"}} 222 +{{layout-cell}} 223 +---- 224 + 225 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 226 + 227 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 228 + 229 +(% class="code" %) 230 +((( 231 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 232 + password: written on control laptop (changes every 6 months) 233 +))) 234 + 235 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 236 + 237 +\\ 238 + 239 +Click "Start" icon in kamzik. 240 + 241 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 242 + 243 +---- 244 +{{/layout-cell}} 245 +{{/layout-section}} 246 + 247 +{{layout-section ac:type="two_equal"}} 248 +{{layout-cell}} 249 +**Check list:** 250 + 251 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 252 + 253 +* Open BS1 (//CrystalControl)// 254 +* Put collimator in (//CrystalControl)// 255 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 256 +* Open fast shutter (//CrystalControl)// 257 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 258 +* Close fast shutter (//CrystalControl)// 259 + 260 +\\ 261 + 262 +**Set run parameters and go 🏃💥** 263 + 264 +1. Set your desired No. of frames 265 +1. Match exposure time with chopper setting 266 +1. Check trigger setting and match to chopper setting 267 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 268 +1. To start the run, click "<Call>" next to //exposure time// 269 + 270 +\\ 271 + 272 +(% style="color: rgb(153,51,102);" %)**//Current bug~://** 273 + 274 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 275 + 276 + 277 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 278 + 279 +(% class="code" %) 280 +((( 281 + cd /gpfs/current/raw/scan_frames 282 + watch "ls -lrt <run number>/ | tail" 283 +\\\\\\\\ 284 +))) 285 +{{/layout-cell}} 286 + 287 +{{layout-cell}} 288 +(% class="wrapped relative-table" style="width: 100.0%;" %) 289 +|=((( 290 +Parameter 291 +)))|=((( 292 +explanation 293 +)))|=(% colspan="1" %)((( 294 +value 295 +))) 296 +|((( 297 +Images number 298 +)))|((( 299 +Set number of frames you want to collect 300 +)))|(% colspan="1" %)((( 301 +usually 100k - 200k, but adjust according to hitrate 302 + 303 +orientation: 10 % hitrate needs at least 100k images 304 +))) 305 +|((( 306 +exposure 307 +)))|((( 308 +exposure time of Eiger 309 + 310 +\\ 311 +)))|(% colspan="1" %)((( 312 +chopper at 133 Hz → 3.7 ms 313 + 314 +chopper at 66 Hz → 7.7 ms 315 + 316 +no chopper → 7.7 ms 317 + 318 +---- 319 +))) 320 +|((( 321 +run id 322 +)))|((( 323 +changes automatically 324 +)))|(% colspan="1" %)((( 325 +\\ 326 +))) 327 +|(% colspan="1" %)((( 328 +Detector distance 329 +)))|(% colspan="1" %)((( 330 +current detector postion readout 331 +)))|(% colspan="1" %)((( 332 +\\ 333 +))) 334 +|(% colspan="1" %)((( 335 +move_detector (distance) 336 +)))|(% colspan="1" %)((( 337 +Set detector distance 338 +)))|(% colspan="1" %)((( 339 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 340 +))) 341 +|(% colspan="1" %)((( 342 +Diode voltage 343 +)))|(% colspan="1" %)((( 344 +read out of diode 345 +)))|(% colspan="1" %)((( 346 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 347 +Call local contact 348 +** 349 +))) 350 +{{/layout-cell}} 351 +{{/layout-section}} 352 + 353 +{{layout-section ac:type="single"}} 354 +{{layout-cell}} 355 +---- 356 + 357 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Troubleshooting"/}}**14.7 Troubleshooting** == 358 + 359 +* ((( 360 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 361 + 362 +* Tape roll empty? 363 +* motor connected (icon green)? 364 +))) 365 + 366 +\\ 367 + 368 +* ((( 369 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 370 + 371 +* displayed in green=connected? 372 +* nozzle holder colliding somewhere? 373 +* motor limits reached? → position displayed in red 374 +))) 375 + 376 +\\ 377 + 378 +* ((( 379 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 380 + 381 +* channel turned on? 382 +* Sample empty? 383 +* Nozzle or lines clogged? → flush with water, change nozzle 384 +))) 385 +{{/layout-cell}} 386 +{{/layout-section}} 387 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23 50321811 +236824604 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23 5032181/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824604/14. Serial Crystallography: CFEL TapeDrive