Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,3 +1,6 @@ 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 1 1 2 2 3 3 {{toc/}} ... ... @@ -115,9 +115,11 @@ 115 115 * ((( 116 116 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 117 117 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 118 -\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 119 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 120 120 122 + 123 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 124 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 125 + 121 121 (% class="wrapped" %) 122 122 |=((( 123 123 \\ ... ... @@ -166,7 +166,7 @@ 166 166 167 167 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 168 168 169 -* The chiller circulates fluid through the gas 174 +* The chiller circulates fluid through the gas nozzle. 170 170 171 171 \\ 172 172 ... ... @@ -195,15 +195,16 @@ 195 195 * Remove the (almost) empty feeder roll by pulling it upwards. 196 196 * Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 197 197 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 198 -* Cut the first cm of the new tape roll, directly be forethe black sticky part.199 -* Usethis stickypart to attach the end of the old tape to thenewroll.Place new rollon roll holder.200 -* Open magnetic tape stabilizer. 201 -* Start the tape (3mm/s). Once the connetion side (black sticky part)has arrived at the collector roll, stop the tape (0mm/s).202 -* Again, cut the tape directly in frontof theblackmark. Replace the the old roll with the **empty **one. Old roll can be discarded.203 -* Attach new tape to the empty roll by using theblackstickypart.203 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 204 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 205 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 206 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 207 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 208 +* Attach new tape to the empty roll by using some sticky tape. 204 204 * Close tape stabilizer. 210 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 205 205 206 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 212 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 207 207 ** 208 208 209 209 \\ ... ... @@ -210,14 +210,142 @@ 210 210 211 211 \\ 212 212 213 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}14.6 Nozzle exchange === 219 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 214 214 215 215 \\ 216 216 217 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}14.7 Data collection === 223 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** === 218 218 225 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 226 + 227 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 228 + password: //written on control laptop (changes every 6 months)// 229 + 230 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 231 + 219 219 \\ 220 220 234 +**Check list:** 235 + 236 +* Open BS1 (//CrystalControl)// 237 +* Put collimator in (//CrystalControl)// 238 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 239 +* Open fast shutter (//CrystalControl)// 240 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 241 +* Close fast shutter (//CrystalControl)// 242 + 243 +\\ 244 + 245 +**Start run in kamzik 246 +** 247 + 248 +Click "Start" icon in kamzik. 249 + 250 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 251 + 252 +---- 253 +{{/layout-cell}} 254 +{{/layout-section}} 255 + 256 +{{layout-section ac:type="two_equal"}} 257 +{{layout-cell}} 258 +\\ 259 + 260 +(% class="task-list" %) 261 +((( 262 +{{task reference="/Tasks/Task_16" status="InProgress"}} 263 +(% class="task-list" %) 264 +((( 265 +{{task reference="/Tasks/Task_22" status="InProgress"}} 266 +Set your desired No. of frames 267 +{{/task}} 268 + 269 +{{task reference="/Tasks/Task_17" status="InProgress"}} 270 +Match exposure time with chopper setting 271 +{{/task}} 272 + 273 +{{task reference="/Tasks/Task_18" status="InProgress"}} 274 +Check trigger setting and match to chopper setting 275 +{{/task}} 276 + 277 +{{task reference="/Tasks/Task_19" status="InProgress"}} 278 +Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 279 +{{/task}} 280 + 281 +{{task reference="/Tasks/Task_20" status="InProgress"}} 282 +To start the run, click "<Call>" next to //exposure time// 283 +{{/task}} 284 +))) 285 +{{/task}} 286 +))) 287 +{{/layout-cell}} 288 + 289 +{{layout-cell}} 290 +(% class="wrapped" %) 291 +|=((( 292 +Parameter 293 +)))|=((( 294 +explanation 295 +)))|=(% colspan="1" %)((( 296 +value 297 +))) 298 +|((( 299 +Images number 300 +)))|((( 301 +Set number of frames you want to collect 302 +)))|(% colspan="1" %)((( 303 +usually 100k - 200k, but adjust according to hitrate 304 + 305 +orientation: 10 % hitrate needs at least 100k images 306 +))) 307 +|((( 308 +exposure 309 +)))|((( 310 +exposure time of Eiger 311 + 312 +\\ 313 +)))|(% colspan="1" %)((( 314 +chopper at 133 Hz → 3.7 ms 315 + 316 +chopper at 66 Hz → 7.7 ms 317 + 318 +no chopper → 7.7 ms 319 + 320 +---- 321 +))) 322 +|((( 323 +run id 324 +)))|((( 325 +changes automatically 326 +)))|(% colspan="1" %)((( 327 +\\ 328 +))) 329 +|(% colspan="1" %)((( 330 +Detector distance 331 +)))|(% colspan="1" %)((( 332 +current detector postion readout 333 +)))|(% colspan="1" %)((( 334 +\\ 335 +))) 336 +|(% colspan="1" %)((( 337 +move_detector (distance) 338 +)))|(% colspan="1" %)((( 339 +Set detector distance 340 +)))|(% colspan="1" %)((( 341 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 342 +))) 343 +|(% colspan="1" %)((( 344 +Diode voltage 345 +)))|(% colspan="1" %)((( 346 +read out of diode 347 +)))|(% colspan="1" %)((( 348 +**~~ 0 !!! higher values indicate missaligned beam stop!!!** 349 +))) 350 +{{/layout-cell}} 351 +{{/layout-section}} 352 + 353 +{{layout-section ac:type="single"}} 354 +{{layout-cell}} 221 221 === {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 222 222 223 223 * ((( ... ... @@ -229,7 +229,6 @@ 229 229 * ((( 230 230 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 231 231 ))) 232 - 233 -\\ 234 - 235 -\\ 366 +{{/layout-cell}} 367 +{{/layout-section}} 368 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2368 159751 +236824567 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2368 15975/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824567/14. Serial Crystallography: CFEL TapeDrive