Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,6 @@ 1 - 2 - 3 -{{toc/}} 4 - 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 5 5 [[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]] 6 6 7 7 \\ ... ... @@ -115,10 +115,11 @@ 115 115 * ((( 116 116 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 117 117 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 118 -\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 119 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 120 120 121 -(% class="wrapped" %) 118 + 119 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 120 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 121 + 122 122 |=((( 123 123 \\ 124 124 )))|=((( ... ... @@ -166,7 +166,7 @@ 166 166 167 167 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 168 168 169 -* The chiller circulates fluid through the gas 169 +* The chiller circulates fluid through the gas nozzle. 170 170 171 171 \\ 172 172 ... ... @@ -195,15 +195,16 @@ 195 195 * Remove the (almost) empty feeder roll by pulling it upwards. 196 196 * Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 197 197 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 198 -* Cut the first cm of the new tape roll, directly be forethe black sticky part.199 -* Usethis stickypart to attach the end of the old tape to thenewroll.Place new rollon roll holder.200 -* Open magnetic tape stabilizer. 201 -* Start the tape (3mm/s). Once the connetion side (black sticky part)has arrived at the collector roll, stop the tape (0mm/s).202 -* Again, cut the tape directly in frontof theblackmark. Replace the the old roll with the **empty **one. Old roll can be discarded.203 -* Attach new tape to the empty roll by using theblackstickypart.198 +* Cut the first cm of the new tape roll, directly behind the black sticky part. 199 +* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 200 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 201 +* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 202 +* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 203 +* Attach new tape to the empty roll by using some sticky tape. 204 204 * Close tape stabilizer. 205 +* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 205 205 206 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 207 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 207 207 ** 208 208 209 209 \\ ... ... @@ -210,26 +210,212 @@ 210 210 211 211 \\ 212 212 213 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}14.6 Nozzle exchange === 214 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 215 +{{/layout-cell}} 216 +{{/layout-section}} 214 214 218 +{{layout-section ac:type="single"}} 219 +{{layout-cell}} 220 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Chopper"/}}**14.7 Chopper** === 221 + 222 +start chopper gui from terminal: 223 + 224 +(% class="code" %) 225 +((( 226 + cd /gpfs/local/shared/ChopperControl 227 +))) 228 + 229 +(% class="code" %) 230 +((( 231 + python chopperControl.py 232 +))) 233 +{{/layout-cell}} 234 +{{/layout-section}} 235 + 236 +{{layout-section ac:type="two_equal"}} 237 +{{layout-cell}} 238 + [[image:attach:20211212_233140.jpg||height="250"]] 239 +{{/layout-cell}} 240 + 241 +{{layout-cell}} 242 +**Chopper → no Chopper** 243 + 244 +* decrease frequency by max. 10 Hz steps\\ 245 +** click arrow down 10x, "Set", arrow down 10x, "Set", .... 246 +* at frequency = 10 Hz, click "Stop" 247 +* set "Hole" to <none> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 248 + 249 +(% style="color: rgb(0,0,0);" %)**no Chopper → Chopper** 250 + 251 +* (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 252 +* (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 253 +** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 254 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 255 +{{/layout-cell}} 256 +{{/layout-section}} 257 + 258 +{{layout-section ac:type="single"}} 259 +{{layout-cell}} 260 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Datacollection"/}}**14.8 Data collection** === 261 + 262 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 263 + 264 +(% class="code" %) 265 +((( 266 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 267 + password: written on control laptop (changes every 6 months) 268 +))) 269 + 270 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 271 + 215 215 \\ 216 216 217 - === {{idname="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}14.7Datacollection===274 +Click "Start" icon in kamzik. 218 218 276 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 277 + 278 +---- 279 +{{/layout-cell}} 280 +{{/layout-section}} 281 + 282 +{{layout-section ac:type="two_equal"}} 283 +{{layout-cell}} 284 +**Check list:** 285 + 286 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 287 + 288 +* Open BS1 (//CrystalControl)// 289 +* Put collimator in (//CrystalControl)// 290 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 291 +* Open fast shutter (//CrystalControl)// 292 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 293 +* Close fast shutter (//CrystalControl)// 294 + 219 219 \\ 220 220 221 - === {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting===297 +**Set run parameters and go 🏃💥** 222 222 299 +1. Set your desired No. of frames 300 +1. Match exposure time with chopper setting 301 +1. Check trigger setting and match to chopper setting 302 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 303 +1. To start the run, click "<Call>" next to //exposure time// 304 + 305 +\\ 306 + 307 +(% style="color: rgb(153,51,102);" %)**//Current bug~://** 308 + 309 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 310 + 311 + 312 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 313 + 314 +(% class="code" %) 315 +((( 316 + cd /gpfs/current/raw/scan_frames 317 + watch "ls -lrt <run number>/ | tail" 318 +\\\\\\\\ 319 +))) 320 +{{/layout-cell}} 321 + 322 +{{layout-cell}} 323 +(% class="wrapped relative-table" style="width: 100.0%;" %) 324 +|=((( 325 +Parameter 326 +)))|=((( 327 +explanation 328 +)))|=(% colspan="1" %)((( 329 +value 330 +))) 331 +|((( 332 +Images number 333 +)))|((( 334 +Set number of frames you want to collect 335 +)))|(% colspan="1" %)((( 336 +usually 100k - 200k, but adjust according to hitrate 337 + 338 +orientation: 10 % hitrate needs at least 100k images 339 +))) 340 +|((( 341 +exposure 342 +)))|((( 343 +exposure time of Eiger 344 + 345 +\\ 346 +)))|(% colspan="1" %)((( 347 +chopper at 133 Hz → 3.7 ms 348 + 349 +chopper at 66 Hz → 7.7 ms 350 + 351 +no chopper → 7.7 ms 352 + 353 +---- 354 +))) 355 +|((( 356 +run id 357 +)))|((( 358 +changes automatically 359 +)))|(% colspan="1" %)((( 360 +\\ 361 +))) 362 +|(% colspan="1" %)((( 363 +Detector distance 364 +)))|(% colspan="1" %)((( 365 +current detector postion readout 366 +)))|(% colspan="1" %)((( 367 +\\ 368 +))) 369 +|(% colspan="1" %)((( 370 +move_detector (distance) 371 +)))|(% colspan="1" %)((( 372 +Set detector distance 373 +)))|(% colspan="1" %)((( 374 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 375 +))) 376 +|(% colspan="1" %)((( 377 +Diode voltage 378 +)))|(% colspan="1" %)((( 379 +read out of diode 380 +)))|(% colspan="1" %)((( 381 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 382 +Call local contact 383 +** 384 +))) 385 +{{/layout-cell}} 386 +{{/layout-section}} 387 + 388 +{{layout-section ac:type="single"}} 389 +{{layout-cell}} 390 +---- 391 + 392 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.9Troubleshooting"/}}14.9 Troubleshooting === 393 + 223 223 * ((( 224 224 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 396 + 397 +* Tape roll empty? 398 +* motor connected (icon green)? 225 225 ))) 400 + 401 +\\ 402 + 226 226 * ((( 227 227 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 405 + 406 +* displayed in green=connected? 407 +* nozzle holder colliding somewhere? 408 +* motor limits reached? → position displayed in red 228 228 ))) 229 -* ((( 230 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 231 -))) 232 232 233 233 \\ 234 234 235 -\\ 413 +* ((( 414 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 415 + 416 +* channel turned on? 417 +* Sample empty? 418 +* Nozzle or lines clogged? → flush with water, change nozzle 419 +))) 420 +{{/layout-cell}} 421 +{{/layout-section}} 422 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2368 159751 +236824590 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2368 15975/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824590/14. Serial Crystallography: CFEL TapeDrive