Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,3 +1,6 @@ 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 1 1 2 2 3 3 {{toc/}} ... ... @@ -115,9 +115,11 @@ 115 115 * ((( 116 116 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 117 117 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 118 -\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 119 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 120 120 122 + 123 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 124 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 125 + 121 121 (% class="wrapped" %) 122 122 |=((( 123 123 \\ ... ... @@ -204,7 +204,7 @@ 204 204 * Close tape stabilizer. 205 205 * Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 206 206 207 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 212 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 208 208 ** 209 209 210 210 \\ ... ... @@ -211,14 +211,120 @@ 211 211 212 212 \\ 213 213 214 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}14.6 Nozzle exchange === 219 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 215 215 216 216 \\ 217 217 218 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}14.7 Data collection === 223 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** === 219 219 225 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 226 + 227 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 228 + password: //written on control laptop (changes every 6 months)// 229 + 230 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 231 + 220 220 \\ 221 221 234 +**Check list:** 235 + 236 +* Open BS1 (//CrystalControl)// 237 +* Put collimator in (//CrystalControl)// 238 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 239 +* Open fast shutter (//CrystalControl)// 240 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 241 +* Close fast shutter (//CrystalControl)// 242 + 243 +\\ 244 + 245 +**Start run in kamzik 246 +** 247 + 248 +Click "Start" icon in kamzik. 249 + 250 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 251 + 252 +---- 253 +{{/layout-cell}} 254 +{{/layout-section}} 255 + 256 +{{layout-section ac:type="two_equal"}} 257 +{{layout-cell}} 258 +\\ 259 + 260 +1. Set your desired No. of frames 261 +1. Match exposure time with chopper setting 262 +1. Check trigger setting and match to chopper setting 263 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 264 +1. To start the run, click "<Call>" next to //exposure time// 265 +{{/layout-cell}} 266 + 267 +{{layout-cell}} 268 +(% class="wrapped" %) 269 +|=((( 270 +Parameter 271 +)))|=((( 272 +explanation 273 +)))|=(% colspan="1" %)((( 274 +value 275 +))) 276 +|((( 277 +Images number 278 +)))|((( 279 +Set number of frames you want to collect 280 +)))|(% colspan="1" %)((( 281 +usually 100k - 200k, but adjust according to hitrate 282 + 283 +orientation: 10 % hitrate needs at least 100k images 284 +))) 285 +|((( 286 +exposure 287 +)))|((( 288 +exposure time of Eiger 289 + 290 +\\ 291 +)))|(% colspan="1" %)((( 292 +chopper at 133 Hz → 3.7 ms 293 + 294 +chopper at 66 Hz → 7.7 ms 295 + 296 +no chopper → 7.7 ms 297 + 298 +---- 299 +))) 300 +|((( 301 +run id 302 +)))|((( 303 +changes automatically 304 +)))|(% colspan="1" %)((( 305 +\\ 306 +))) 307 +|(% colspan="1" %)((( 308 +Detector distance 309 +)))|(% colspan="1" %)((( 310 +current detector postion readout 311 +)))|(% colspan="1" %)((( 312 +\\ 313 +))) 314 +|(% colspan="1" %)((( 315 +move_detector (distance) 316 +)))|(% colspan="1" %)((( 317 +Set detector distance 318 +)))|(% colspan="1" %)((( 319 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 320 +))) 321 +|(% colspan="1" %)((( 322 +Diode voltage 323 +)))|(% colspan="1" %)((( 324 +read out of diode 325 +)))|(% colspan="1" %)((( 326 +**~~ 0 !!! higher values indicate missaligned beam stop!!!** 327 +))) 328 +{{/layout-cell}} 329 +{{/layout-section}} 330 + 331 +{{layout-section ac:type="single"}} 332 +{{layout-cell}} 222 222 === {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 223 223 224 224 * ((( ... ... @@ -230,7 +230,6 @@ 230 230 * ((( 231 231 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 232 232 ))) 233 - 234 -\\ 235 - 236 -\\ 344 +{{/layout-cell}} 345 +{{/layout-section}} 346 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2368245 611 +236824573 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2368245 61/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824573/14. Serial Crystallography: CFEL TapeDrive