Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,3 +1,6 @@ 1 +{{layout}} 2 +{{layout-section ac:type="single"}} 3 +{{layout-cell}} 1 1 2 2 3 3 {{toc/}} ... ... @@ -221,15 +221,30 @@ 221 221 222 222 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 223 223 224 - xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 225 - password: //written on control laptop (changes every 6 months)// 227 +(% class="code" %) 228 +((( 229 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 230 + password: written on control laptop (changes every 6 months) 231 +))) 226 226 227 227 //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 228 228 229 229 \\ 230 230 237 +Click "Start" icon in kamzik. 238 + 239 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 240 + 241 +---- 242 +{{/layout-cell}} 243 +{{/layout-section}} 244 + 245 +{{layout-section ac:type="two_equal"}} 246 +{{layout-cell}} 231 231 **Check list:** 232 232 249 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 250 + 233 233 * Open BS1 (//CrystalControl)// 234 234 * Put collimator in (//CrystalControl)// 235 235 * Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// ... ... @@ -239,13 +239,32 @@ 239 239 240 240 \\ 241 241 242 -**Start run in kamzik 243 -** 260 +**Set run parameters and go 🏃💥** 244 244 245 -Click "Start" icon in kamzik. 262 +1. Set your desired No. of frames 263 +1. Match exposure time with chopper setting 264 +1. Check trigger setting and match to chopper setting 265 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 266 +1. To start the run, click "<Call>" next to //exposure time// 246 246 247 - [[image:attach:kamzik_run-tile.jpg||height="400"]]268 +\\ 248 248 270 +(% style="color: rgb(153,51,102);" %)**//Current bug~://** 271 + 272 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 273 + 274 + 275 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 276 + 277 +(% class="code" %) 278 +((( 279 + cd /gpfs/current/raw/scan_frames 280 + watch "ls -lrt <run number>/ | tail" 281 +))) 282 +{{/layout-cell}} 283 + 284 +{{layout-cell}} 285 +(% class="wrapped relative-table" style="width: 100.0%;" %) 249 249 |=((( 250 250 Parameter 251 251 )))|=((( ... ... @@ -303,40 +303,15 @@ 303 303 )))|(% colspan="1" %)((( 304 304 read out of diode 305 305 )))|(% colspan="1" %)((( 306 -**~~ 0 !!! higher values indicate missaligned beam stop!!!** 343 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 344 +Call local contact 345 +** 307 307 ))) 347 +{{/layout-cell}} 348 +{{/layout-section}} 308 308 309 ----- 310 - 311 -(% class="task-list" %) 312 -((( 313 -{{task reference="/Tasks/Task_6" status="InProgress"}} 314 -Set your desired No. of frames 315 -{{/task}} 316 - 317 -{{task reference="/Tasks/Task_7" status="InProgress"}} 318 -Match exposure time with chopper setting 319 -{{/task}} 320 - 321 -{{task reference="/Tasks/Task_8" status="InProgress"}} 322 -Check trigger setting and match to chopper setting 323 -{{/task}} 324 - 325 -{{task reference="/Tasks/Task_9" status="InProgress"}} 326 -Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 327 -{{/task}} 328 - 329 -{{task reference="/Tasks/Task_10" status="InProgress"}} 330 -To start the run, click "<Call>" next to //exposure time// 331 -{{/task}} 332 -))) 333 - 334 ----- 335 - 336 -\\ 337 - 338 -\\ 339 - 350 +{{layout-section ac:type="single"}} 351 +{{layout-cell}} 340 340 === {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 341 341 342 342 * ((( ... ... @@ -348,7 +348,6 @@ 348 348 * ((( 349 349 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 350 350 ))) 351 - 352 -\\ 353 - 354 -\\ 363 +{{/layout-cell}} 364 +{{/layout-section}} 365 +{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2368245 621 +236824574 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2368245 62/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824574/14. Serial Crystallography: CFEL TapeDrive