... ... @@ -1,3 +1,6 @@
1 +{{layout}}
2 +{{layout-section ac:type="single"}}
3 +{{layout-cell}}
1 1  
2 2  
3 3  {{toc/}}
... ... @@ -221,15 +221,30 @@
221 221  
222 222  Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
223 223  
224 - xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611
225 - password: //written on control laptop (changes every 6 months)//
227 +(% class="code" %)
228 +(((
229 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611
230 + password: written on control laptop (changes every 6 months)
231 +)))
226 226  
227 227   //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password//
228 228  
229 229  \\
230 230  
237 +Click "Start" icon in kamzik.
238 +
239 +[[image:attach:kamzik_run-tile.jpg||height="400"]]
240 +
241 +----
242 +{{/layout-cell}}
243 +{{/layout-section}}
244 +
245 +{{layout-section ac:type="two_equal"}}
246 +{{layout-cell}}
231 231  **Check list:**
232 232  
249 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!//
250 +
233 233  * Open BS1  (//CrystalControl)//
234 234  * Put collimator in (//CrystalControl)//
235 235  * Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)//
... ... @@ -239,13 +239,32 @@
239 239  
240 240  \\
241 241  
242 -**Start run in kamzik
243 -**
260 +**Set run parameters and go 🏃💥**
244 244  
245 -Click "Start" icon in kamzik.
262 +1. Set your desired No. of frames
263 +1. Match exposure time with chopper setting
264 +1. Check trigger setting and match to chopper setting
265 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it.
266 +1. To start the run, click "<Call>" next to //exposure time//
246 246  
247 -[[image:attach:kamzik_run-tile.jpg||height="400"]]
268 +\\
248 248  
270 +(% style="color: rgb(153,51,102);" %)**//Current bug~://**
271 +
272 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>".
273 +
274 +
275 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with:
276 +
277 +(% class="code" %)
278 +(((
279 + cd /gpfs/current/raw/scan_frames
280 + watch "ls -lrt <run number>/ | tail"
281 +)))
282 +{{/layout-cell}}
283 +
284 +{{layout-cell}}
285 +(% class="wrapped relative-table" style="width: 100.0%;" %)
249 249  |=(((
250 250  Parameter
251 251  )))|=(((
... ... @@ -303,40 +303,15 @@
303 303  )))|(% colspan="1" %)(((
304 304  read out of diode
305 305  )))|(% colspan="1" %)(((
306 -**~~ 0 !!! higher values indicate missaligned beam stop!!!**
343 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 
344 +Call local contact
345 +**
307 307  )))
347 +{{/layout-cell}}
348 +{{/layout-section}}
308 308  
309 -----
310 -
311 -(% class="task-list" %)
312 -(((
313 -{{task reference="/Tasks/Task_6" status="InProgress"}}
314 -Set your desired No. of frames
315 -{{/task}}
316 -
317 -{{task reference="/Tasks/Task_7" status="InProgress"}}
318 -Match exposure time with chopper setting
319 -{{/task}}
320 -
321 -{{task reference="/Tasks/Task_8" status="InProgress"}}
322 -Check trigger setting and match to chopper setting
323 -{{/task}}
324 -
325 -{{task reference="/Tasks/Task_9" status="InProgress"}}
326 -Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it.
327 -{{/task}}
328 -
329 -{{task reference="/Tasks/Task_10" status="InProgress"}}
330 -To start the run, click "<Call>" next to //exposure time//
331 -{{/task}}
332 -)))
333 -
334 -----
335 -
336 -\\
337 -
338 -\\
339 -
350 +{{layout-section ac:type="single"}}
351 +{{layout-cell}}
340 340  === {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting ===
341 341  
342 342  * (((
... ... @@ -348,7 +348,6 @@
348 348  * (((
349 349  ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ====
350 350  )))
351 -
352 -\\
353 -
354 -\\
363 +{{/layout-cell}}
364 +{{/layout-section}}
365 +{{/layout}}
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -236824562
1 +236824574
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/11/pages/236824562/14. Serial Crystallography: CFEL TapeDrive
1 +https://confluence.desy.de/spaces/11/pages/236824574/14. Serial Crystallography: CFEL TapeDrive