Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +4,3 @@ 1 -{{layout}} 2 -{{layout-section ac:type="single"}} 3 -{{layout-cell}} 4 4 5 5 6 6 {{toc/}} ... ... @@ -82,16 +82,14 @@ 82 82 83 83 Be aware to which channel and nozzle line your sample is connected. 84 84 85 - Red → Channel 1, crystal line (nozzle capillary without marks /with red marks)82 + Red → Channel 1, crystal line (nozzle capillary without marks) 86 86 87 87 Green → Channel 2, substrate line (nozzle capillary is marked in black) 88 88 89 89 [[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 90 90 91 - After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O.88 +\\ 92 92 93 -[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 94 - 95 95 \\ 96 96 97 97 === {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation ... ... @@ -112,17 +112,15 @@ 112 112 \\ 113 113 * [[image:attach:kamzik_tape.PNG||height="400"]] 114 114 115 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 110 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle:"/}}**Sample nozzle:** ==== 116 116 117 117 * Click an the 'nozzle' icon. 118 118 * ((( 119 119 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 120 120 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 116 +\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 117 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 121 121 122 - 123 -(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 124 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 125 - 126 126 (% class="wrapped" %) 127 127 |=((( 128 128 \\ ... ... @@ -171,16 +171,12 @@ 171 171 172 172 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 173 173 174 - * The chiller circulates fluid through the gas nozzle.167 +\\ 175 175 176 176 \\ 177 177 178 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 179 - 180 180 \\ 181 181 182 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 183 - 184 184 \\ 185 185 186 186 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -193,7 +193,7 @@ 193 193 194 194 \\ 195 195 196 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** === 185 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** ==== 197 197 198 198 The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 199 199 ... ... @@ -200,16 +200,15 @@ 200 200 * Remove the (almost) empty feeder roll by pulling it upwards. 201 201 * Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 202 202 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 203 -* Cut the first cm of the new tape roll, directly be hindthe black sticky part.204 -* Placenew roll on rollholder and usestickytapeto attach the end of the old tape to thebeginningofthe new roll.205 -* Open magnetic tape stabilizer on the **left side**.//!!!BEAMSTOP!!!//206 -* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 207 -* Again, cut the tape directly behindthe connectionside. Replace the the old roll with the **empty **one. Old roll can be discarded.208 -* Attach new tape to the empty roll by using some stickytape.192 +* Cut the first cm of the new tape roll, directly before the black sticky part. 193 +* Use this sticky part to attach the end of the old tape to the new roll. Place new roll on roll holder. 194 +* Open magnetic tape stabilizer. 195 +* Start the tape (3mm/s). Once the connetion side (black sticky part) has arrived at the collector roll, stop the tape (0mm/s). 196 +* Again, cut the tape directly in front of the black mark. Replace the the old roll with the **empty **one. Old roll can be discarded. 197 +* Attach new tape to the empty roll by using the black sticky part. 209 209 * Close tape stabilizer. 210 -* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 211 211 212 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] [[image:attach:tape reset.PNG||height="250"]]200 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 213 213 ** 214 214 215 215 \\ ... ... @@ -216,145 +216,8 @@ 216 216 217 217 \\ 218 218 219 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 220 - 221 221 \\ 222 222 223 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** === 224 - 225 -Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 226 - 227 - xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 228 - password: //written on control laptop (changes every 6 months)// 229 - 230 - //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 231 - 232 232 \\ 233 233 234 -**Check list:** 235 - 236 -* Open BS1 (//CrystalControl)// 237 -* Put collimator in (//CrystalControl)// 238 -* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 239 -* Open fast shutter (//CrystalControl)// 240 -* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 241 -* Close fast shutter (//CrystalControl)// 242 - 243 243 \\ 244 - 245 -**Start run in kamzik 246 -** 247 - 248 -Click "Start" icon in kamzik. 249 - 250 -[[image:attach:kamzik_run-tile.jpg||height="400"]] 251 - 252 ----- 253 -{{/layout-cell}} 254 -{{/layout-section}} 255 - 256 -{{layout-section ac:type="two_equal"}} 257 -{{layout-cell}} 258 -(% class="task-list" %) 259 -((( 260 -{{task reference="/Tasks/Task_16" status="InProgress"}} 261 -Set your desired No. of frames 262 -{{/task}} 263 - 264 -{{task reference="/Tasks/Task_17" status="InProgress"}} 265 -Match exposure time with chopper setting 266 -{{/task}} 267 - 268 -{{task reference="/Tasks/Task_18" status="InProgress"}} 269 -Check trigger setting and match to chopper setting 270 -{{/task}} 271 - 272 -{{task reference="/Tasks/Task_19" status="InProgress"}} 273 -Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 274 -{{/task}} 275 - 276 -{{task reference="/Tasks/Task_20" status="InProgress"}} 277 -To start the run, click "<Call>" next to //exposure time// 278 -{{/task}} 279 -))) 280 -{{/layout-cell}} 281 - 282 -{{layout-cell}} 283 -|=((( 284 -Parameter 285 -)))|=((( 286 -explanation 287 -)))|=(% colspan="1" %)((( 288 -value 289 -))) 290 -|((( 291 -Images number 292 -)))|((( 293 -Set number of frames you want to collect 294 -)))|(% colspan="1" %)((( 295 -usually 100k - 200k, but adjust according to hitrate 296 - 297 -orientation: 10 % hitrate needs at least 100k images 298 -))) 299 -|((( 300 -exposure 301 -)))|((( 302 -exposure time of Eiger 303 - 304 -\\ 305 -)))|(% colspan="1" %)((( 306 -chopper at 133 Hz → 3.7 ms 307 - 308 -chopper at 66 Hz → 7.7 ms 309 - 310 -no chopper → 7.7 ms 311 - 312 ----- 313 -))) 314 -|((( 315 -run id 316 -)))|((( 317 -changes automatically 318 -)))|(% colspan="1" %)((( 319 -\\ 320 -))) 321 -|(% colspan="1" %)((( 322 -Detector distance 323 -)))|(% colspan="1" %)((( 324 -current detector postion readout 325 -)))|(% colspan="1" %)((( 326 -\\ 327 -))) 328 -|(% colspan="1" %)((( 329 -move_detector (distance) 330 -)))|(% colspan="1" %)((( 331 -Set detector distance 332 -)))|(% colspan="1" %)((( 333 -200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 334 -))) 335 -|(% colspan="1" %)((( 336 -Diode voltage 337 -)))|(% colspan="1" %)((( 338 -read out of diode 339 -)))|(% colspan="1" %)((( 340 -**~~ 0 !!! higher values indicate missaligned beam stop!!!** 341 -))) 342 -{{/layout-cell}} 343 -{{/layout-section}} 344 - 345 -{{layout-section ac:type="single"}} 346 -{{layout-cell}} 347 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 348 - 349 -* ((( 350 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 351 -))) 352 -* ((( 353 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 354 -))) 355 -* ((( 356 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 357 -))) 358 -{{/layout-cell}} 359 -{{/layout-section}} 360 -{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23 68245661 +235039466 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23 6824566/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/235039466/14. Serial Crystallography: CFEL TapeDrive