Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +4,3 @@ 1 -{{layout}} 2 -{{layout-section ac:type="single"}} 3 -{{layout-cell}} 4 4 5 5 6 6 {{toc/}} ... ... @@ -118,11 +118,9 @@ 118 118 * ((( 119 119 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 120 120 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 118 +\\(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 119 +\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 121 121 122 - 123 -(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 124 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 125 - 126 126 (% class="wrapped" %) 127 127 |=((( 128 128 \\ ... ... @@ -209,7 +209,7 @@ 209 209 * Close tape stabilizer. 210 210 * Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 211 211 212 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] [[image:attach:tape reset.PNG||height="250"]]207 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]] 213 213 ** 214 214 215 215 \\ ... ... @@ -216,142 +216,14 @@ 216 216 217 217 \\ 218 218 219 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}} **14.6 Nozzle exchange**===214 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}14.6 Nozzle exchange === 220 220 221 221 \\ 222 222 223 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}} **14.7 Data collection**===218 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}14.7 Data collection === 224 224 225 -Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 226 - 227 - xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 228 - password: //written on control laptop (changes every 6 months)// 229 - 230 - //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 231 - 232 232 \\ 233 233 234 -**Check list:** 235 - 236 -* Open BS1 (//CrystalControl)// 237 -* Put collimator in (//CrystalControl)// 238 -* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 239 -* Open fast shutter (//CrystalControl)// 240 -* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 241 -* Close fast shutter (//CrystalControl)// 242 - 243 -\\ 244 - 245 -**Start run in kamzik 246 -** 247 - 248 -Click "Start" icon in kamzik. 249 - 250 -[[image:attach:kamzik_run-tile.jpg||height="400"]] 251 - 252 ----- 253 -{{/layout-cell}} 254 -{{/layout-section}} 255 - 256 -{{layout-section ac:type="two_equal"}} 257 -{{layout-cell}} 258 -\\ 259 - 260 -(% class="task-list" %) 261 -((( 262 -{{task reference="/Tasks/Task_16" status="InProgress"}} 263 -(% class="task-list" %) 264 -((( 265 -{{task reference="/Tasks/Task_22" status="InProgress"}} 266 -Set your desired No. of frames 267 -{{/task}} 268 - 269 -{{task reference="/Tasks/Task_17" status="InProgress"}} 270 -Match exposure time with chopper setting 271 -{{/task}} 272 - 273 -{{task reference="/Tasks/Task_18" status="InProgress"}} 274 -Check trigger setting and match to chopper setting 275 -{{/task}} 276 - 277 -{{task reference="/Tasks/Task_19" status="InProgress"}} 278 -Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 279 -{{/task}} 280 - 281 -{{task reference="/Tasks/Task_20" status="InProgress"}} 282 -To start the run, click "<Call>" next to //exposure time// 283 -{{/task}} 284 -))) 285 -{{/task}} 286 -))) 287 -{{/layout-cell}} 288 - 289 -{{layout-cell}} 290 -(% class="wrapped" %) 291 -|=((( 292 -Parameter 293 -)))|=((( 294 -explanation 295 -)))|=(% colspan="1" %)((( 296 -value 297 -))) 298 -|((( 299 -Images number 300 -)))|((( 301 -Set number of frames you want to collect 302 -)))|(% colspan="1" %)((( 303 -usually 100k - 200k, but adjust according to hitrate 304 - 305 -orientation: 10 % hitrate needs at least 100k images 306 -))) 307 -|((( 308 -exposure 309 -)))|((( 310 -exposure time of Eiger 311 - 312 -\\ 313 -)))|(% colspan="1" %)((( 314 -chopper at 133 Hz → 3.7 ms 315 - 316 -chopper at 66 Hz → 7.7 ms 317 - 318 -no chopper → 7.7 ms 319 - 320 ----- 321 -))) 322 -|((( 323 -run id 324 -)))|((( 325 -changes automatically 326 -)))|(% colspan="1" %)((( 327 -\\ 328 -))) 329 -|(% colspan="1" %)((( 330 -Detector distance 331 -)))|(% colspan="1" %)((( 332 -current detector postion readout 333 -)))|(% colspan="1" %)((( 334 -\\ 335 -))) 336 -|(% colspan="1" %)((( 337 -move_detector (distance) 338 -)))|(% colspan="1" %)((( 339 -Set detector distance 340 -)))|(% colspan="1" %)((( 341 -200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 342 -))) 343 -|(% colspan="1" %)((( 344 -Diode voltage 345 -)))|(% colspan="1" %)((( 346 -read out of diode 347 -)))|(% colspan="1" %)((( 348 -**~~ 0 !!! higher values indicate missaligned beam stop!!!** 349 -))) 350 -{{/layout-cell}} 351 -{{/layout-section}} 352 - 353 -{{layout-section ac:type="single"}} 354 -{{layout-cell}} 355 355 === {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 356 356 357 357 * ((( ... ... @@ -363,6 +363,7 @@ 363 363 * ((( 364 364 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 365 365 ))) 366 -{{/layout-cell}} 367 -{{/layout-section}} 368 -{{/layout}} 233 + 234 +\\ 235 + 236 +\\
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23682456 71 +236824561 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23682456 7/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824561/14. Serial Crystallography: CFEL TapeDrive