Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -218,62 +218,33 @@ 218 218 219 219 === {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 220 220 221 - === {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Chopper"/}}**14.7 Chopper** ===221 +\\ 222 222 223 -star t chopperguifromterminal:223 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Datacollection"/}}**14.7 Data collection** === 224 224 225 -(% class="code" %) 226 -((( 227 - cd /gpfs/local/shared/ChopperControl 228 -))) 225 +Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 229 229 230 -(% class="code" %) 231 -((( 232 - python chopperControl.py 233 -))) 227 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 228 + password: //written on control laptop (changes every 6 months)// 234 234 235 ----- 236 -{{/layout-cell}} 237 -{{/layout-section}} 230 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 238 238 239 -{{layout-section ac:type="two_equal"}} 240 -{{layout-cell}} 241 - [[image:attach:20211212_233140.jpg||height="250"]] 242 -{{/layout-cell}} 232 +\\ 243 243 244 -{{layout-cell}} 245 -**Chopper → no Chopper** 234 +**Check list:** 246 246 247 -* decrease frequency by max. 10 Hz steps\\ 248 -** click arrow down 10x, "Set", arrow down 10x, "Set", .... 249 -* at frequency = 10 Hz, click "Stop" 250 -* set "Hole" to <none> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 236 +* Open BS1 (//CrystalControl)// 237 +* Put collimator in (//CrystalControl)// 238 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 239 +* Open fast shutter (//CrystalControl)// 240 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 241 +* Close fast shutter (//CrystalControl)// 251 251 252 -(% style="color: rgb(0,0,0);" %)**no Chopper → Chopper** 253 - 254 -* (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 255 -* (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 256 -** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 257 -* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 258 -{{/layout-cell}} 259 -{{/layout-section}} 260 - 261 -{{layout-section ac:type="single"}} 262 -{{layout-cell}} 263 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Datacollection"/}}**14.8 Data collection** === 264 - 265 -Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 266 - 267 -(% class="code" %) 268 -((( 269 - xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 270 - password: written on control laptop (changes every 6 months) 271 -))) 272 - 273 - //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 274 - 275 275 \\ 276 276 245 +**Start run in kamzik 246 +** 247 + 277 277 Click "Start" icon in kamzik. 278 278 279 279 [[image:attach:kamzik_run-tile.jpg||height="400"]] ... ... @@ -284,46 +284,17 @@ 284 284 285 285 {{layout-section ac:type="two_equal"}} 286 286 {{layout-cell}} 287 -**Check list:** 288 - 289 -(% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 290 - 291 -* Open BS1 (//CrystalControl)// 292 -* Put collimator in (//CrystalControl)// 293 -* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 294 -* Open fast shutter (//CrystalControl)// 295 -* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 296 -* Close fast shutter (//CrystalControl)// 297 - 298 298 \\ 299 299 300 -**Set run parameters and go 🏃💥** 301 - 302 302 1. Set your desired No. of frames 303 303 1. Match exposure time with chopper setting 304 304 1. Check trigger setting and match to chopper setting 305 305 1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 306 306 1. To start the run, click "<Call>" next to //exposure time// 307 - 308 -\\ 309 - 310 -(% style="color: rgb(153,51,102);" %)**//Current bug~://** 311 - 312 -(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 313 - 314 - 315 -(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 316 - 317 -(% class="code" %) 318 -((( 319 - cd /gpfs/current/raw/scan_frames 320 - watch "ls -lrt <run number>/ | tail" 321 -\\\\\\\\ 322 -))) 323 323 {{/layout-cell}} 324 324 325 325 {{layout-cell}} 326 -(% class="wrapped relative-table"style="width: 100.0%;" %)268 +(% class="wrapped" %) 327 327 |=((( 328 328 Parameter 329 329 )))|=((( ... ... @@ -381,9 +381,7 @@ 381 381 )))|(% colspan="1" %)((( 382 382 read out of diode 383 383 )))|(% colspan="1" %)((( 384 -**~~ 0 !!! higher values indicate missaligned beam stop!!! 385 -Call local contact 386 -** 326 +**~~ 0 !!! higher values indicate missaligned beam stop!!!** 387 387 ))) 388 388 {{/layout-cell}} 389 389 {{/layout-section}} ... ... @@ -390,35 +390,16 @@ 390 390 391 391 {{layout-section ac:type="single"}} 392 392 {{layout-cell}} 393 -- ---333 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Troubleshooting"/}}14.8 Troubleshooting === 394 394 395 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.9Troubleshooting"/}}14.9 Troubleshooting === 396 - 397 397 * ((( 398 398 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 399 - 400 -* Tape roll empty? 401 -* motor connected (icon green)? 402 402 ))) 403 - 404 -\\ 405 - 406 406 * ((( 407 407 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 408 - 409 -* displayed in green=connected? 410 -* nozzle holder colliding somewhere? 411 -* motor limits reached? → position displayed in red 412 412 ))) 413 - 414 -\\ 415 - 416 416 * ((( 417 417 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 418 - 419 -* channel turned on? 420 -* Sample empty? 421 -* Nozzle or lines clogged? → flush with water, change nozzle 422 422 ))) 423 423 {{/layout-cell}} 424 424 {{/layout-section}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2368245 891 +236824573 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2368245 89/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824573/14. Serial Crystallography: CFEL TapeDrive