Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,66 +1,18 @@ 1 1 {{layout}} 2 2 {{layout-section ac:type="single"}} 3 3 {{layout-cell}} 4 -[[image:attach:TapeDrive_beschriftet-tile.jpg||height=" 400"]]4 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="250"]] 5 5 6 6 \\ 7 7 8 - \\8 +{{toc minLevel="2"/}} 9 9 10 10 \\ 11 11 12 - === {{id name="14.SerialCrystallography:CFELTapeDrive-14.1RevertfromCrystallographytoTapeDrive(P11staff/CFEL)"/}}**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** ===12 +---- 13 13 14 -* remove vortex 15 -* beamstop to out-position? 16 -* remove goniometer. The airbearing should be stopped (p11/servermotor/eh.1.01) 17 -* move cryojet out of the way, ramp the cryo up and shut it down. Close the compressed air to the shield flow. The biggest cable kinks and needs to be disconnected. 18 -* stop refill of the robot dewar and empty the dewar, warm up. 19 -* Disable backlight (unplug Festo connection). (% style="color: rgb(255,0,0);" %)//Is this still needed?// 20 -* (% style="color: rgb(0,0,0);" %)mount the 10 um diode and connect (via connector on the granite). This is connected to the leftmost Keithly (power up, check that settings are gain E06, Filter on, Rise time 1 ms. Keithly is connected to the oscilloscope and the delay generator, delay generator is connected to oscilloscope and detector, see diagram in P11 wiki. (% style="color: rgb(0, 0, 0); color: rgb(255, 0, 0)" %)//Insert here the setting for oscilloscope//(% style="color: rgb(0,0,0);" %)//. //Make sure to connect the multi-trigger to the back of the detector instead of the standard trigger, when starting to use the chopper (pull the thin ring with ‘grip’ area to detach). Cables are labeled. Make sure before using the chopper that the channels are enabled. 21 -* (% style="color: rgb(0,0,0);" %)move goniotower to X ~~ 17 000 14 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** == 22 22 23 -(% style="color: rgb(0,0,0);" %)Mounting of the TapeDrive is done by the CFEL group. Electronics and control units are combined on a small shelf, that requires only one power and network plug-in. The shelf will be placed left-sided (looking upstream) to the detector tower. The ElveFlow and control laptop as well as several necessary consumables are placed on a cart, which is to be positioned on the right (looking upstream) against the robot platform. The CFEL chiller is placed on the right of the platform and connected to the TapeDrive GASnozzle. 24 - 25 -\\ 26 - 27 -* adjust focus of the tape by moving X in goniometer tower until you see it in the overview camera. Final adjustment should be done when there is flow. Latest value is about 4500 in X and also 5000 in Z (higher soft limit changed from 2976,63 to 6000). (% style="color: rgb(255,0,0);" %)//Better to use the back illumination in the GUI to focus the tape - old instruction, not sure if this is the case. Back illumination is the external light source in the detector tower (the crystallography backlight should be disable for tapedrive).// 28 -* (% style="color: rgb(0,0,0);" %)Check the Minimum Detector Distance; the detector should not collide with the tapedrive while driven to 154 mm but it has to be verified. Also check that all cables and capillaries are taped away when the users start, so that nothing protrudes further than the tapedrive itself. Soft limit can be edited in eh.3.11 Atk panel. 29 -* (% style="color: rgb(0,0,0);" %)Reconfirm the alignment of the beamstop, once everything, including the nozzle, is in place. Modify config.ini for beamstop in- and out-position to both mach in (27 000). This way the beamstop will not be driven out when the hutch is opened, to avoid that the users forget to drive it in when restarting after entering the hutch. 30 - 31 -\\ 32 - 33 -Prepare necessary controls for data collection: 34 - 35 -* ATK panels: 36 -** p11/simplon_filewriter/eh.01 37 -** p11/simplon_detector/eh.01 38 -*** count time = 0.0075 39 -*** trigger (**ints **if working without the chopper, # or triggers is 1, **exts** if with the chopper, # or triggers = number of images). Exts is also the standard trigger in normal crystallography. If GUI is used to take images (e.g. for beamstop alignment) the trigger mode will be forced by that and needs to be reverted manually for the users to continue. 40 -*** numer of images = 100 000 41 -*** number of images in container = 1000 42 -*** mode 16m/4M 43 -*** detector distance = 200 mm (usually) 44 -** p11/detectortower 45 -** p11/motor/eh.09 46 -* remote access to TapeDrive control laptop: 47 -** open terminal, execute command: xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 48 - password: //written on control laptop 49 -// 50 -* Cameras: 51 -** haspp11ethcam1 → detector tower camera to monitor nozzle 52 -** haspp11ethcam4 → goniometer camera to monitor tape from above 53 -* OnDa (on haspp11user04): 54 -//This starts both GUIs (Frame Viewer & Crystallography GUI) and onda-monitor, the server component. The tool has a bunch of parameters which you can list with ./onda-runner.py —help.//\\ 55 -** 16M mode → cd /home/p11user/CfelSoft/202103_onda 56 - ./onda-runner.py onda-config/onda-config-Eiger16M.toml 57 -** 4M mode → cd /home/p11user/CfelSoft/202103_onda 58 - ./onda-runner.py onda-config/onda-config-Eiger4M.toml\\ 59 - 60 -\\ 61 - 62 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2Samplecharacteristicsandpreparation"/}}**14.2 Sample characteristics and preparation** === 63 - 64 64 suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 65 65 66 66 Preparation: ... ... @@ -71,9 +71,11 @@ 71 71 72 72 \\ 73 73 74 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3ConnectingsampletoElveFlow,sampleexchange"/}}**14.3 Connecting sample to ElveFlow, sample exchange 75 -** === 26 +---- 76 76 28 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}**14.2 Connecting sample to ElveFlow, sample exchange 29 +** == 30 + 77 77 After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 78 78 79 79 Be aware to which channel and nozzle line your sample is connected. ... ... @@ -90,9 +90,11 @@ 90 90 91 91 \\ 92 92 93 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation 94 -** === 47 +---- 95 95 49 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}**14.3 TapeDrive operation 50 +** == 51 + 96 96 The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 97 97 Now start the client. Same thing, a terminal will open, shortly after a small window. 98 98 ... ... @@ -99,7 +99,7 @@ 99 99 Click 'Devices' in the **client session** to open the control window. 100 100 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 101 101 102 -**Tape** 58 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ==== 103 103 104 104 * Click on the 'main tape' icon 105 105 * Change the velocity by typing anything from **0.3-3.0 mm/s** ... ... @@ -119,6 +119,7 @@ 119 119 (% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 120 120 \\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 121 121 78 +(% class="wrapped" %) 122 122 |=((( 123 123 \\ 124 124 )))|=((( ... ... @@ -188,8 +188,10 @@ 188 188 189 189 \\ 190 190 191 - === {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** ===148 +---- 192 192 150 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}}**14.4 Tape roll exchange** == 151 + 193 193 The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 194 194 195 195 * Remove the (almost) empty feeder roll by pulling it upwards. ... ... @@ -211,14 +211,17 @@ 211 211 212 212 \\ 213 213 214 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Nozzleexchange"/}}**14.6 Nozzle exchange** === 173 +** 174 +** 215 215 {{/layout-cell}} 216 216 {{/layout-section}} 217 217 218 218 {{layout-section ac:type="single"}} 219 219 {{layout-cell}} 220 - === {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Chopper"/}}**14.7 Chopper** ===180 +---- 221 221 182 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}}**14.5 Chopper** == 183 + 222 222 start chopper gui from terminal: 223 223 224 224 (% class="code" %) ... ... @@ -229,6 +229,7 @@ 229 229 (% class="code" %) 230 230 ((( 231 231 python chopperControl.py 194 +\\\\ 232 232 ))) 233 233 {{/layout-cell}} 234 234 {{/layout-section}} ... ... @@ -255,9 +255,9 @@ 255 255 {{/layout-cell}} 256 256 {{/layout-section}} 257 257 258 -{{layout-section ac:type=" single"}}221 +{{layout-section ac:type="two_equal"}} 259 259 {{layout-cell}} 260 -== ={{id name="14.SerialCrystallography:CFELTapeDrive-14.8Datacollection"/}}**14.8Data collection** ===223 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 261 261 262 262 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 263 263 ... ... @@ -267,33 +267,43 @@ 267 267 password: written on control laptop (changes every 6 months) 268 268 ))) 269 269 270 - //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password//233 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 271 271 272 272 \\ 273 273 274 -C lick"Start"icon in kamzik.237 +**Check list:** 275 275 276 - [[image:attach:kamzik_run-tile.jpg||height="400"]]239 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 277 277 278 ----- 241 +(% style="color: rgb(0,0,0);" %)Click "Safety" icon in kamzik. 242 + 243 +* Put collimator in 244 +** Click "<Call>" next to //collimator_in// 245 + 246 +\\ 247 + 248 +* Open beam shutter BS1 in //CrystalControl// 279 279 {{/layout-cell}} 250 + 251 +{{layout-cell}} 252 +[[image:attach:kamzik_safety.PNG||height="400"]] 253 +{{/layout-cell}} 280 280 {{/layout-section}} 281 281 282 -{{layout-section ac:type=" two_equal"}}256 +{{layout-section ac:type="single"}} 283 283 {{layout-cell}} 284 - **Check list:**258 +---- 285 285 286 - (% style="color:rgb(255,0,0);"%)//always afterenteringthe hutch!//260 +Click "Start/Run" icon in kamzik. 287 287 288 -* Open BS1 (//CrystalControl)// 289 -* Put collimator in (//CrystalControl)// 290 -* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 291 -* Open fast shutter (//CrystalControl)// 292 -* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 293 -* Close fast shutter (//CrystalControl)// 262 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 294 294 295 -\\ 264 +---- 265 +{{/layout-cell}} 266 +{{/layout-section}} 296 296 268 +{{layout-section ac:type="two_equal"}} 269 +{{layout-cell}} 297 297 **Set run parameters and go 🏃💥** 298 298 299 299 1. Set your desired No. of frames ... ... @@ -304,19 +304,17 @@ 304 304 305 305 \\ 306 306 307 - (% style="color: rgb(153,51,102);" %)**//Current bug~://**280 +\\ 308 308 309 - (% style="color:rgb(0,0,0);" %)You needto "Stop" run in kamzikmanually after allimages havebeen acquired.This movestheshield up andclosesthefast shutter.Afterwards youcan start a new run byclicking "<Call>".282 +**After data collection/before entering the exp. hutch** 310 310 284 +1. Go to "Safety" in kamzik. 285 +1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 286 +11. Drive the collimator out 287 +11. Drive the detector back to 1500 mm 288 +1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 311 311 312 -(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 313 - 314 -(% class="code" %) 315 -((( 316 - cd /gpfs/current/raw/scan_frames 317 - watch "ls -lrt <run number>/ | tail" 318 -\\\\\\\\ 319 -))) 290 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 320 320 {{/layout-cell}} 321 321 322 322 {{layout-cell}} ... ... @@ -389,7 +389,7 @@ 389 389 {{layout-cell}} 390 390 ---- 391 391 392 -== ={{id name="14.SerialCrystallography:CFELTapeDrive-14.9Troubleshooting"/}}14.9Troubleshooting ===363 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Troubleshooting"/}}**14.7 Troubleshooting** == 393 393 394 394 * ((( 395 395 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== ... ... @@ -417,6 +417,41 @@ 417 417 * Sample empty? 418 418 * Nozzle or lines clogged? → flush with water, change nozzle 419 419 ))) 391 + 392 +\\ 393 + 394 +* ((( 395 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Simplonfilewriter/eigerstreamissues"/}}Simplon filewriter/eiger stream issues ==== 396 + 397 +* First, restart kamzik (server+client) and see if this solves the issue 398 +* If not, restart the Simplon server (in Astor → haspp11exp03, right click on Simplon/EH.1 and restart) 399 +* ((( 400 +If nothing works, kill the Simplon process and then start the server again:* ((( 401 +(% class="code" %) 402 +((( 403 +ssh haspp11exp03 404 +))) 405 +))) 406 +* ((( 407 +(% class="code" %) 408 +((( 409 +ps -ef | grep Simplon 410 +))) 411 +))) 412 +* ((( 413 +(% class="code" %) 414 +((( 415 +kill -9 simplon_process_id 416 +))) 417 +))) 418 +))) 419 +))) 420 420 {{/layout-cell}} 421 421 {{/layout-section}} 422 + 423 +{{layout-section ac:type="single"}} 424 +{{layout-cell}} 425 +\\ 426 +{{/layout-cell}} 427 +{{/layout-section}} 422 422 {{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2 368245901 +250178623 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2 36824590/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/250178623/14. Serial Crystallography: CFEL TapeDrive