Last modified by chatzies on 2025-11-27 11:35

From version 45.1
edited by ahenkel
on 2021-12-12 23:53
Change comment: There is no comment for this version
To version 1.1
edited by ahenkel
on 2021-11-30 10:29
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -14. Serial Crystallography: CFEL TapeDrive
1 +Serial Crystallography: CFEL TapeDrive
Content
... ... @@ -1,372 +1,0 @@
1 -{{layout}}
2 -{{layout-section ac:type="single"}}
3 -{{layout-cell}}
4 -[[image:attach:TapeDrive_beschriftet-tile.jpg||height="250"]]
5 -
6 -\\
7 -
8 -\\
9 -
10 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** ==
11 -
12 -suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.
13 -
14 -Preparation:
15 -
16 -* filter through 30 µm cell filter (green) into Eppendorf or Falcon (original!) tube
17 -
18 -[[image:attach:20211201_095534.jpg||height="250"]]
19 -
20 -\\
21 -
22 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}**14.2 Connecting sample to ElveFlow, sample exchange
23 -** ==
24 -
25 -After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!**
26 -
27 -Be aware to which channel and nozzle line your sample is connected.
28 -
29 - Red → Channel 1, crystal line (nozzle capillary without marks/with red marks)
30 -
31 - Green → Channel 2, substrate line (nozzle capillary is marked in black)
32 -
33 -[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]]
34 -
35 -After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O.
36 -
37 -[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]]
38 -
39 -\\
40 -
41 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}**14.3 TapeDrive operation
42 -** ==
43 -
44 -The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window.
45 -Now start the client. Same thing, a terminal will open, shortly after a small window.
46 -
47 -Click 'Devices' in the **client session** to open the control window.
48 -[[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]]
49 -
50 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ====
51 -
52 -* Click on the 'main tape' icon
53 -* Change the velocity by typing anything from **0.3-3.0 mm/s**
54 -* Common velocity is 1.0-1.5 mm/s
55 -* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point.
56 -\\
57 -* [[image:attach:kamzik_tape.PNG||height="400"]]
58 -
59 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ====
60 -
61 -* Click an the 'nozzle' icon.
62 -* (((
63 -The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully.
64 -The absolute position is **not calibrated** and therefore changes after each restart of kamzik.
65 -
66 -
67 -(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%)
68 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments.
69 -
70 -(% class="wrapped" %)
71 -|=(((
72 -\\
73 -)))|=(((
74 -direction
75 -)))|=(((
76 -recommended step size
77 -for visual adjustment
78 -)))|=(% colspan="1" %)(((
79 -recommended step size
80 -during data collection
81 -)))
82 -|(((
83 -+x
84 -)))|(((
85 -away from X-ray interaction point
86 -)))|(((
87 -1.0 - 0.5 mm
88 -)))|(% colspan="1" %)(((
89 -0.1 - 0.2 mm
90 -)))
91 -|(((
92 -+y
93 -)))|(((
94 -up
95 -)))|(((
96 -1.0 - 0.5 mm
97 -)))|(% colspan="1" %)(((
98 -0.1 - 0.2 mm
99 -)))
100 -|(((
101 -+z
102 -)))|(((
103 -towards detector tower, away from tape
104 -)))|(((
105 -0.5 - 0.2 mm
106 -)))|(% colspan="1" %)(((
107 -0.1 - 0.2 mm
108 -be careful with -z, tape could be pushed out of focus
109 -)))
110 -
111 -**
112 -\\**
113 -)))
114 -* [[image:attach:kamzik_nozzle.PNG||height="400"]]
115 -
116 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ====
117 -
118 -* The chiller circulates fluid through the gas nozzle.
119 -
120 -\\
121 -
122 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ====
123 -
124 -\\
125 -
126 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ====
127 -
128 -\\
129 -
130 -Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
131 -
132 - xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611
133 - password: //written on control laptop (changes every 6 months)
134 -//
135 -
136 -\\
137 -
138 -\\
139 -
140 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** ==
141 -
142 -The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s).
143 -
144 -* Remove the (almost) empty feeder roll by pulling it upwards.
145 -* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!**
146 -* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm**
147 -* Cut the first cm of the new tape roll, directly behind the black sticky part.
148 -* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll.
149 -* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!//
150 -* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s).
151 -* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded.
152 -* Attach new tape to the empty roll by using some sticky tape.
153 -* Close tape stabilizer.
154 -* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape".
155 -
156 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]]
157 -**
158 -
159 -\\
160 -
161 -\\
162 -
163 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-"/}}**
164 -** ===
165 -{{/layout-cell}}
166 -{{/layout-section}}
167 -
168 -{{layout-section ac:type="single"}}
169 -{{layout-cell}}
170 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Chopper"/}}**14.7 Chopper** ==
171 -
172 -start chopper gui from terminal:
173 -
174 -(% class="code" %)
175 -(((
176 - cd /gpfs/local/shared/ChopperControl
177 -)))
178 -
179 -(% class="code" %)
180 -(((
181 - python chopperControl.py
182 -)))
183 -{{/layout-cell}}
184 -{{/layout-section}}
185 -
186 -{{layout-section ac:type="two_equal"}}
187 -{{layout-cell}}
188 - [[image:attach:20211212_233140.jpg||height="250"]]
189 -{{/layout-cell}}
190 -
191 -{{layout-cell}}
192 -**Chopper → no Chopper**
193 -
194 -* decrease frequency by max. 10 Hz steps\\
195 -** click arrow down 10x, "Set", arrow down 10x, "Set", ....
196 -* at frequency = 10 Hz, click "Stop"
197 -* set "Hole" to <none> (% style="color: rgb(255,0,0);" %)//Takes some minutes//
198 -
199 -(% style="color: rgb(0,0,0);" %)**no Chopper → Chopper**
200 -
201 -* (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes//
202 -* (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps
203 -** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", .....
204 -* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms//
205 -{{/layout-cell}}
206 -{{/layout-section}}
207 -
208 -{{layout-section ac:type="single"}}
209 -{{layout-cell}}
210 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Datacollection"/}}**14.8 Data collection** ==
211 -
212 -Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
213 -
214 -(% class="code" %)
215 -(((
216 - xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611
217 - password: written on control laptop (changes every 6 months)
218 -)))
219 -
220 - //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password//
221 -
222 -\\
223 -
224 -Click "Start" icon in kamzik.
225 -
226 -[[image:attach:kamzik_run-tile.jpg||height="400"]]
227 -
228 -----
229 -{{/layout-cell}}
230 -{{/layout-section}}
231 -
232 -{{layout-section ac:type="two_equal"}}
233 -{{layout-cell}}
234 -**Check list:**
235 -
236 -(% style="color: rgb(255,0,0);" %)//always after entering the hutch!//
237 -
238 -* Open BS1  (//CrystalControl)//
239 -* Put collimator in (//CrystalControl)//
240 -* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)//
241 -* Open fast shutter (//CrystalControl)//
242 -* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)//
243 -* Close fast shutter (//CrystalControl)//
244 -
245 -\\
246 -
247 -**Set run parameters and go 🏃💥**
248 -
249 -1. Set your desired No. of frames
250 -1. Match exposure time with chopper setting
251 -1. Check trigger setting and match to chopper setting
252 -1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it.
253 -1. To start the run, click "<Call>" next to //exposure time//
254 -
255 -\\
256 -
257 -(% style="color: rgb(153,51,102);" %)**//Current bug~://**
258 -
259 -(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>".
260 -
261 -
262 -(% style="color: rgb(0,0,0);" %)Check progress in terminal with:
263 -
264 -(% class="code" %)
265 -(((
266 - cd /gpfs/current/raw/scan_frames
267 - watch "ls -lrt <run number>/ | tail"
268 -\\\\\\\\
269 -)))
270 -{{/layout-cell}}
271 -
272 -{{layout-cell}}
273 -(% class="wrapped relative-table" style="width: 100.0%;" %)
274 -|=(((
275 -Parameter
276 -)))|=(((
277 -explanation
278 -)))|=(% colspan="1" %)(((
279 -value
280 -)))
281 -|(((
282 -Images number
283 -)))|(((
284 -Set number of frames you want to collect
285 -)))|(% colspan="1" %)(((
286 -usually 100k - 200k, but adjust according to hitrate
287 -
288 -orientation: 10 % hitrate needs at least 100k images
289 -)))
290 -|(((
291 -exposure
292 -)))|(((
293 -exposure time of Eiger
294 -
295 -\\
296 -)))|(% colspan="1" %)(((
297 -chopper at 133 Hz → 3.7 ms
298 -
299 -chopper at 66 Hz   → 7.7 ms
300 -
301 -no chopper            → 7.7 ms
302 -
303 -----
304 -)))
305 -|(((
306 -run id
307 -)))|(((
308 -changes automatically
309 -)))|(% colspan="1" %)(((
310 -\\
311 -)))
312 -|(% colspan="1" %)(((
313 -Detector distance
314 -)))|(% colspan="1" %)(((
315 -current detector postion readout
316 -)))|(% colspan="1" %)(((
317 -\\
318 -)))
319 -|(% colspan="1" %)(((
320 -move_detector (distance)
321 -)))|(% colspan="1" %)(((
322 -Set detector distance
323 -)))|(% colspan="1" %)(((
324 -200.0 mm   (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>"
325 -)))
326 -|(% colspan="1" %)(((
327 -Diode voltage
328 -)))|(% colspan="1" %)(((
329 -read out of diode
330 -)))|(% colspan="1" %)(((
331 -**~~ 0 !!! higher values indicate missaligned beam stop!!! 
332 -Call local contact
333 -**
334 -)))
335 -{{/layout-cell}}
336 -{{/layout-section}}
337 -
338 -{{layout-section ac:type="single"}}
339 -{{layout-cell}}
340 -----
341 -
342 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.9Troubleshooting"/}}**14.9 Troubleshooting** ==
343 -
344 -* (((
345 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ====
346 -
347 -* Tape roll empty?
348 -* motor connected (icon green)?
349 -)))
350 -
351 -\\
352 -
353 -* (((
354 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ====
355 -
356 -* displayed in green=connected?
357 -* nozzle holder colliding somewhere?
358 -* motor limits reached? → position displayed in red
359 -)))
360 -
361 -\\
362 -
363 -* (((
364 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ====
365 -
366 -* channel turned on?
367 -* Sample empty?
368 -* Nozzle or lines clogged? → flush with water, change nozzle
369 -)))
370 -{{/layout-cell}}
371 -{{/layout-section}}
372 -{{/layout}}
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -236824595
1 +235031814
Title
... ... @@ -1,1 +1,1 @@
1 -14. Serial Crystallography: CFEL TapeDrive
1 +Serial Crystallography: CFEL TapeDrive
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/11/pages/236824595/14. Serial Crystallography: CFEL TapeDrive
1 +https://confluence.desy.de/spaces/11/pages/235031814/Serial Crystallography: CFEL TapeDrive