Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,387 +1,3 @@ 1 -{{layout}} 2 -{{layout-section ac:type="single"}} 3 -{{layout-cell}} 4 -[[image:attach:TapeDrive_beschriftet-tile.jpg||height="250"]] 1 +**14.1 Revert from Crystallography to TapeDrive (P11 staff)** 5 5 6 6 \\ 7 - 8 -{{toc minLevel="2"/}} 9 - 10 -\\ 11 - 12 ----- 13 - 14 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** == 15 - 16 -suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 17 - 18 -Preparation: 19 - 20 -* filter through 30 µm cell filter (green) into Eppendorf or Falcon (original!) tube 21 - 22 -[[image:attach:20211201_095534.jpg||height="250"]] 23 - 24 -\\ 25 - 26 ----- 27 - 28 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}**14.2 Connecting sample to ElveFlow, sample exchange 29 -** == 30 - 31 -After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 32 - 33 -Be aware to which channel and nozzle line your sample is connected. 34 - 35 - Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) 36 - 37 - Green → Channel 2, substrate line (nozzle capillary is marked in black) 38 - 39 -[[image:attach:20211201_095033.jpg||thumbnail="true" height="250"]] 40 - 41 -After finishing data collection, flush all lines by connecting an Eppi or syringe filled with ddH,,2,,O. 42 - 43 -[[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 44 - 45 -\\ 46 - 47 ----- 48 - 49 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}**14.3 TapeDrive operation 50 -** == 51 - 52 -The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 53 -Now start the client. Same thing, a terminal will open, shortly after a small window. 54 - 55 -Click 'Devices' in the **client session** to open the control window. 56 -[[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 57 - 58 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ==== 59 - 60 -* Click on the 'main tape' icon 61 -* Change the velocity by typing anything from **0.3-3.0 mm/s** 62 -* Common velocity is 1.0-1.5 mm/s 63 -* kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 64 -\\ 65 -* [[image:attach:kamzik_tape.PNG||height="400"]] 66 - 67 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 68 - 69 -* Click an the 'nozzle' icon. 70 -* ((( 71 -The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 72 -The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 73 - 74 - 75 -(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 76 -\\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 77 - 78 -(% class="wrapped" %) 79 -|=((( 80 -\\ 81 -)))|=((( 82 -direction 83 -)))|=((( 84 -recommended step size 85 -for visual adjustment 86 -)))|=(% colspan="1" %)((( 87 -recommended step size 88 -during data collection 89 -))) 90 -|((( 91 -+x 92 -)))|((( 93 -away from X-ray interaction point 94 -)))|((( 95 -1.0 - 0.5 mm 96 -)))|(% colspan="1" %)((( 97 -0.1 - 0.2 mm 98 -))) 99 -|((( 100 -+y 101 -)))|((( 102 -up 103 -)))|((( 104 -1.0 - 0.5 mm 105 -)))|(% colspan="1" %)((( 106 -0.1 - 0.2 mm 107 -))) 108 -|((( 109 -+z 110 -)))|((( 111 -towards detector tower, away from tape 112 -)))|((( 113 -0.5 - 0.2 mm 114 -)))|(% colspan="1" %)((( 115 -0.1 - 0.2 mm 116 -be careful with -z, tape could be pushed out of focus 117 -))) 118 - 119 -** 120 -\\** 121 -))) 122 -* [[image:attach:kamzik_nozzle.PNG||height="400"]] 123 - 124 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 125 - 126 -* The chiller circulates fluid through the gas nozzle. 127 - 128 -\\ 129 - 130 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 131 - 132 -\\ 133 - 134 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 135 - 136 -\\ 137 - 138 -Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 139 - 140 - xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 141 - password: //written on control laptop (changes every 6 months) 142 -// 143 - 144 -\\ 145 - 146 -\\ 147 - 148 ----- 149 - 150 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}}**14.4 Tape roll exchange** == 151 - 152 -The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 153 - 154 -* Remove the (almost) empty feeder roll by pulling it upwards. 155 -* Cut the tape with some cm overlap to glue to the new roll. **Do not discard empty roll!** 156 -* Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 157 -* Cut the first cm of the new tape roll, directly behind the black sticky part. 158 -* Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 159 -* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 160 -* Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 161 -* Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 162 -* Attach new tape to the empty roll by using some sticky tape. 163 -* Close tape stabilizer. 164 -* Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 165 - 166 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 167 -** 168 - 169 -\\ 170 - 171 -\\ 172 - 173 -=== {{id name="14.SerialCrystallography:CFELTapeDrive-"/}}** 174 -** === 175 -{{/layout-cell}} 176 -{{/layout-section}} 177 - 178 -{{layout-section ac:type="single"}} 179 -{{layout-cell}} 180 ----- 181 - 182 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}}**14.5 Chopper** == 183 - 184 -start chopper gui from terminal: 185 - 186 -(% class="code" %) 187 -((( 188 - cd /gpfs/local/shared/ChopperControl 189 -))) 190 - 191 -(% class="code" %) 192 -((( 193 - python chopperControl.py 194 -\\\\ 195 -))) 196 -{{/layout-cell}} 197 -{{/layout-section}} 198 - 199 -{{layout-section ac:type="two_equal"}} 200 -{{layout-cell}} 201 - [[image:attach:20211212_233140.jpg||height="250"]] 202 -{{/layout-cell}} 203 - 204 -{{layout-cell}} 205 -**Chopper → no Chopper** 206 - 207 -* decrease frequency by max. 10 Hz steps\\ 208 -** click arrow down 10x, "Set", arrow down 10x, "Set", .... 209 -* at frequency = 10 Hz, click "Stop" 210 -* set "Hole" to <none> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 211 - 212 -(% style="color: rgb(0,0,0);" %)**no Chopper → Chopper** 213 - 214 -* (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 215 -* (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 216 -** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 217 -* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 218 -{{/layout-cell}} 219 -{{/layout-section}} 220 - 221 -{{layout-section ac:type="single"}} 222 -{{layout-cell}} 223 ----- 224 - 225 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 226 - 227 -Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 228 - 229 -(% class="code" %) 230 -((( 231 - xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 232 - password: written on control laptop (changes every 6 months) 233 -))) 234 - 235 - //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 236 - 237 -\\ 238 - 239 -Click "Start" icon in kamzik. 240 - 241 -[[image:attach:kamzik_run-tile.jpg||height="400"]] 242 - 243 ----- 244 -{{/layout-cell}} 245 -{{/layout-section}} 246 - 247 -{{layout-section ac:type="two_equal"}} 248 -{{layout-cell}} 249 -**Check list:** 250 - 251 -(% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 252 - 253 -* Open BS1 (//CrystalControl)// 254 -* Put collimator in (//CrystalControl)// 255 -* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 256 -* Open fast shutter (//CrystalControl)// 257 -* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 258 -* Close fast shutter (//CrystalControl)// 259 - 260 -\\ 261 - 262 -**Set run parameters and go 🏃💥** 263 - 264 -1. Set your desired No. of frames 265 -1. Match exposure time with chopper setting 266 -1. Check trigger setting and match to chopper setting 267 -1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 268 -1. To start the run, click "<Call>" next to //exposure time// 269 - 270 -\\ 271 - 272 -(% style="color: rgb(153,51,102);" %)**//Current bug~://** 273 - 274 -(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 275 - 276 - 277 -(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 278 - 279 -(% class="code" %) 280 -((( 281 - cd /gpfs/current/raw/scan_frames 282 - watch "ls -lrt <run number>/ | tail" 283 -\\\\\\\\ 284 -))) 285 -{{/layout-cell}} 286 - 287 -{{layout-cell}} 288 -(% class="wrapped relative-table" style="width: 100.0%;" %) 289 -|=((( 290 -Parameter 291 -)))|=((( 292 -explanation 293 -)))|=(% colspan="1" %)((( 294 -value 295 -))) 296 -|((( 297 -Images number 298 -)))|((( 299 -Set number of frames you want to collect 300 -)))|(% colspan="1" %)((( 301 -usually 100k - 200k, but adjust according to hitrate 302 - 303 -orientation: 10 % hitrate needs at least 100k images 304 -))) 305 -|((( 306 -exposure 307 -)))|((( 308 -exposure time of Eiger 309 - 310 -\\ 311 -)))|(% colspan="1" %)((( 312 -chopper at 133 Hz → 3.7 ms 313 - 314 -chopper at 66 Hz → 7.7 ms 315 - 316 -no chopper → 7.7 ms 317 - 318 ----- 319 -))) 320 -|((( 321 -run id 322 -)))|((( 323 -changes automatically 324 -)))|(% colspan="1" %)((( 325 -\\ 326 -))) 327 -|(% colspan="1" %)((( 328 -Detector distance 329 -)))|(% colspan="1" %)((( 330 -current detector postion readout 331 -)))|(% colspan="1" %)((( 332 -\\ 333 -))) 334 -|(% colspan="1" %)((( 335 -move_detector (distance) 336 -)))|(% colspan="1" %)((( 337 -Set detector distance 338 -)))|(% colspan="1" %)((( 339 -200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 340 -))) 341 -|(% colspan="1" %)((( 342 -Diode voltage 343 -)))|(% colspan="1" %)((( 344 -read out of diode 345 -)))|(% colspan="1" %)((( 346 -**~~ 0 !!! higher values indicate missaligned beam stop!!! 347 -Call local contact 348 -** 349 -))) 350 -{{/layout-cell}} 351 -{{/layout-section}} 352 - 353 -{{layout-section ac:type="single"}} 354 -{{layout-cell}} 355 ----- 356 - 357 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Troubleshooting"/}}**14.7 Troubleshooting** == 358 - 359 -* ((( 360 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 361 - 362 -* Tape roll empty? 363 -* motor connected (icon green)? 364 -))) 365 - 366 -\\ 367 - 368 -* ((( 369 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 370 - 371 -* displayed in green=connected? 372 -* nozzle holder colliding somewhere? 373 -* motor limits reached? → position displayed in red 374 -))) 375 - 376 -\\ 377 - 378 -* ((( 379 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 380 - 381 -* channel turned on? 382 -* Sample empty? 383 -* Nozzle or lines clogged? → flush with water, change nozzle 384 -))) 385 -{{/layout-cell}} 386 -{{/layout-section}} 387 -{{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -23 68246041 +235032181 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/23 6824604/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/235032181/14. Serial Crystallography: CFEL TapeDrive