Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -5,14 +5,62 @@ 5 5 6 6 \\ 7 7 8 - {{toc minLevel="2"/}}8 +\\ 9 9 10 10 \\ 11 11 12 -- ---12 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1RevertfromCrystallographytoTapeDrive(P11staff/CFEL)"/}}**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** === 13 13 14 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** == 14 +* remove vortex 15 +* beamstop to out-position? 16 +* remove goniometer. The airbearing should be stopped (p11/servermotor/eh.1.01) 17 +* move cryojet out of the way, ramp the cryo up and shut it down. Close the compressed air to the shield flow. The biggest cable kinks and needs to be disconnected. 18 +* stop refill of the robot dewar and empty the dewar, warm up. 19 +* Disable backlight (unplug Festo connection). (% style="color: rgb(255,0,0);" %)//Is this still needed?// 20 +* (% style="color: rgb(0,0,0);" %)mount the 10 um diode and connect (via connector on the granite). This is connected to the leftmost Keithly (power up, check that settings are gain E06, Filter on, Rise time 1 ms. Keithly is connected to the oscilloscope and the delay generator, delay generator is connected to oscilloscope and detector, see diagram in P11 wiki. (% style="color: rgb(0, 0, 0); color: rgb(255, 0, 0)" %)//Insert here the setting for oscilloscope//(% style="color: rgb(0,0,0);" %)//. //Make sure to connect the multi-trigger to the back of the detector instead of the standard trigger, when starting to use the chopper (pull the thin ring with ‘grip’ area to detach). Cables are labeled. Make sure before using the chopper that the channels are enabled. 21 +* (% style="color: rgb(0,0,0);" %)move goniotower to X ~~ 17 000 15 15 23 +(% style="color: rgb(0,0,0);" %)Mounting of the TapeDrive is done by the CFEL group. Electronics and control units are combined on a small shelf, that requires only one power and network plug-in. The shelf will be placed left-sided (looking upstream) to the detector tower. The ElveFlow and control laptop as well as several necessary consumables are placed on a cart, which is to be positioned on the right (looking upstream) against the robot platform. The CFEL chiller is placed on the right of the platform and connected to the TapeDrive GASnozzle. 24 + 25 +\\ 26 + 27 +* adjust focus of the tape by moving X in goniometer tower until you see it in the overview camera. Final adjustment should be done when there is flow. Latest value is about 4500 in X and also 5000 in Z (higher soft limit changed from 2976,63 to 6000). (% style="color: rgb(255,0,0);" %)//Better to use the back illumination in the GUI to focus the tape - old instruction, not sure if this is the case. Back illumination is the external light source in the detector tower (the crystallography backlight should be disable for tapedrive).// 28 +* (% style="color: rgb(0,0,0);" %)Check the Minimum Detector Distance; the detector should not collide with the tapedrive while driven to 154 mm but it has to be verified. Also check that all cables and capillaries are taped away when the users start, so that nothing protrudes further than the tapedrive itself. Soft limit can be edited in eh.3.11 Atk panel. 29 +* (% style="color: rgb(0,0,0);" %)Reconfirm the alignment of the beamstop, once everything, including the nozzle, is in place. Modify config.ini for beamstop in- and out-position to both mach in (27 000). This way the beamstop will not be driven out when the hutch is opened, to avoid that the users forget to drive it in when restarting after entering the hutch. 30 + 31 +\\ 32 + 33 +Prepare necessary controls for data collection: 34 + 35 +* ATK panels: 36 +** p11/simplon_filewriter/eh.01 37 +** p11/simplon_detector/eh.01 38 +*** count time = 0.0075 39 +*** trigger (**ints **if working without the chopper, # or triggers is 1, **exts** if with the chopper, # or triggers = number of images). Exts is also the standard trigger in normal crystallography. If GUI is used to take images (e.g. for beamstop alignment) the trigger mode will be forced by that and needs to be reverted manually for the users to continue. 40 +*** numer of images = 100 000 41 +*** number of images in container = 1000 42 +*** mode 16m/4M 43 +*** detector distance = 200 mm (usually) 44 +** p11/detectortower 45 +** p11/motor/eh.09 46 +* remote access to TapeDrive control laptop: 47 +** open terminal, execute command: xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 48 + password: //written on control laptop 49 +// 50 +* Cameras: 51 +** haspp11ethcam1 → detector tower camera to monitor nozzle 52 +** haspp11ethcam4 → goniometer camera to monitor tape from above 53 +* OnDa (on haspp11user04): 54 +//This starts both GUIs (Frame Viewer & Crystallography GUI) and onda-monitor, the server component. The tool has a bunch of parameters which you can list with ./onda-runner.py —help.//\\ 55 +** 16M mode → cd /home/p11user/CfelSoft/202103_onda 56 + ./onda-runner.py onda-config/onda-config-Eiger16M.toml 57 +** 4M mode → cd /home/p11user/CfelSoft/202103_onda 58 + ./onda-runner.py onda-config/onda-config-Eiger4M.toml\\ 59 + 60 +\\ 61 + 62 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2Samplecharacteristicsandpreparation"/}}**14.2 Sample characteristics and preparation** === 63 + 16 16 suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 17 17 18 18 Preparation: ... ... @@ -23,11 +23,9 @@ 23 23 24 24 \\ 25 25 26 ----- 74 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3ConnectingsampletoElveFlow,sampleexchange"/}}**14.3 Connecting sample to ElveFlow, sample exchange 75 +** === 27 27 28 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}**14.2 Connecting sample to ElveFlow, sample exchange 29 -** == 30 - 31 31 After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 32 32 33 33 Be aware to which channel and nozzle line your sample is connected. ... ... @@ -44,11 +44,9 @@ 44 44 45 45 \\ 46 46 47 ----- 93 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation 94 +** === 48 48 49 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}**14.3 TapeDrive operation 50 -** == 51 - 52 52 The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 53 53 Now start the client. Same thing, a terminal will open, shortly after a small window. 54 54 ... ... @@ -55,7 +55,7 @@ 55 55 Click 'Devices' in the **client session** to open the control window. 56 56 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 57 57 58 - ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape**====102 +**Tape** 59 59 60 60 * Click on the 'main tape' icon 61 61 * Change the velocity by typing anything from **0.3-3.0 mm/s** ... ... @@ -145,10 +145,8 @@ 145 145 146 146 \\ 147 147 148 -- ---192 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** === 149 149 150 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}}**14.4 Tape roll exchange** == 151 - 152 152 The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 153 153 154 154 * Remove the (almost) empty feeder roll by pulling it upwards. ... ... @@ -170,17 +170,15 @@ 170 170 171 171 \\ 172 172 173 -** 174 -** 215 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-"/}}** 216 +** === 175 175 {{/layout-cell}} 176 176 {{/layout-section}} 177 177 178 178 {{layout-section ac:type="single"}} 179 179 {{layout-cell}} 180 -- ---222 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Chopper"/}}**14.7 Chopper** === 181 181 182 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}}**14.5 Chopper** == 183 - 184 184 start chopper gui from terminal: 185 185 186 186 (% class="code" %) ... ... @@ -191,7 +191,6 @@ 191 191 (% class="code" %) 192 192 ((( 193 193 python chopperControl.py 194 -\\\\ 195 195 ))) 196 196 {{/layout-cell}} 197 197 {{/layout-section}} ... ... @@ -220,10 +220,8 @@ 220 220 221 221 {{layout-section ac:type="single"}} 222 222 {{layout-cell}} 223 -- ---262 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Datacollection"/}}**14.8 Data collection** === 224 224 225 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 226 - 227 227 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 228 228 229 229 (% class="code" %) ... ... @@ -354,7 +354,7 @@ 354 354 {{layout-cell}} 355 355 ---- 356 356 357 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14. 7Troubleshooting"/}}**14.7Troubleshooting**==394 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.9Troubleshooting"/}}14.9 Troubleshooting === 358 358 359 359 * ((( 360 360 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ====
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2 501778451 +236824593 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2 50177845/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824593/14. Serial Crystallography: CFEL TapeDrive