... ... @@ -1,7 +1,7 @@
1 1  {{layout}}
2 2  {{layout-section ac:type="single"}}
3 3  {{layout-cell}}
4 -[[image:attach:TapeDrive_beschriftet-tile.jpg||height="250"]]
4 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]]
5 5  
6 6  \\
7 7  
... ... @@ -13,11 +13,11 @@
13 13  
14 14  == {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** ==
15 15  
16 -suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.
16 +suspension of microcrystals, **at least** 200 µL with 20% crystal density (more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.
17 17  
18 18  Preparation:
19 19  
20 -* filter through 30 µm cell filter (green) into Eppendorf or Falcon (original!) tube
20 +* filter through 30 µm cell filter (green) or 50 µm (yellow) into Eppendorf or Falcon (original!) tube
21 21  
22 22  [[image:attach:20211201_095534.jpg||height="250"]]
23 23  
... ... @@ -57,7 +57,7 @@
57 57  
58 58  ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ====
59 59  
60 -* Click on the 'main tape' icon
60 +* Click the 'main tape' icon
61 61  * Change the velocity by typing anything from **0.3-3.0 mm/s**
62 62  * Common velocity is 1.0-1.5 mm/s
63 63  * kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point.
... ... @@ -66,7 +66,7 @@
66 66  
67 67  ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ====
68 68  
69 -* Click an the 'nozzle' icon.
69 +* Click on the 'nozzle' icon.
70 70  * (((
71 71  The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully.
72 72  The absolute position is **not calibrated** and therefore changes after each restart of kamzik.
... ... @@ -156,7 +156,7 @@
156 156  * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm**
157 157  * Cut the first cm of the new tape roll, directly behind the black sticky part.
158 158  * Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll.
159 -* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!//
159 +* Open magnetic tape stabilizer on the **left side**. (% style="color: rgb(255,0,0);" %)//!!!BEAMSTOP!!!//
160 160  * Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s).
161 161  * Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded.
162 162  * Attach new tape to the empty roll by using some sticky tape.
... ... @@ -214,7 +214,8 @@
214 214  * (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes//
215 215  * (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps
216 216  ** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", .....
217 -* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms//
217 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms (technical exposure will always be 7.7 ms, since max. frame rate is 133 Hz
218 +//
218 218  {{/layout-cell}}
219 219  {{/layout-section}}
220 220  
... ... @@ -232,60 +232,47 @@
232 232   password: written on control laptop (changes every 6 months)
233 233  )))
234 234  
235 - //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password//
236 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password//
236 236  
237 237  \\
238 -
239 -Click "Start" icon in kamzik.
240 -
241 -[[image:attach:kamzik_run-tile.jpg||height="400"]]
242 -
243 -----
244 244  {{/layout-cell}}
245 245  {{/layout-section}}
246 246  
247 -{{layout-section ac:type="two_equal"}}
242 +{{layout-section ac:type="two_left_sidebar"}}
248 248  {{layout-cell}}
249 249  **Check list:**
250 250  
251 251  (% style="color: rgb(255,0,0);" %)//always after entering the hutch!//
252 252  
253 -* Open BS1  (//CrystalControl)//
254 -* Put collimator in (//CrystalControl)//
255 -* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)//
256 -* Open fast shutter (//CrystalControl)//
257 -* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)//
258 -* Close fast shutter (//CrystalControl)//
248 +(% style="color: rgb(0,0,0);" %)Click "Run" icon in kamzik.
259 259  
250 +* Put collimator in
251 +** Put detector distance 200 in //prepare_for_measurement (      )
252 +//
253 +** Click "<Call>" next to //prepare_for_measurement//
254 +
260 260  \\
261 261  
262 -**Set run parameters and go 🏃💥**
257 +* Open beam shutter BS1 in //CrystalControl //or// P11 XRayFeed //
263 263  
264 -1. Set your desired No. of frames
265 -1. Match exposure time with chopper setting
266 -1. Check trigger setting and match to chopper setting
267 -1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it.
268 -1. To start the run, click "<Call>" next to //exposure time//
269 -
270 270  \\
271 271  
272 -(% style="color: rgb(153,51,102);" %)**//Current bug~://**
261 +//**Set run parameters and go 🏃💥**//
273 273  
274 -(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>".
263 +1. Set your desired No. of frames
264 +1. Match exposure time with chopper setting or set desired exposure time
265 +1. Check trigger setting and match to chopper setting
266 +1. To start the run, click "<Call>" next to //start_run (exposure    )//
267 +{{/layout-cell}}
275 275  
276 -
277 -(% style="color: rgb(0,0,0);" %)Check progress in terminal with:
278 -
279 -(% class="code" %)
280 -(((
281 - cd /gpfs/current/raw/scan_frames
282 - watch "ls -lrt <run number>/ | tail"
283 -\\\\\\\\
284 -)))
269 +{{layout-cell}}
270 +[[image:attach:Kamzik_run(2).PNG]]
285 285  {{/layout-cell}}
272 +{{/layout-section}}
286 286  
274 +{{layout-section ac:type="single"}}
287 287  {{layout-cell}}
288 -(% class="wrapped relative-table" style="width: 100.0%;" %)
276 +(% class="relative-table wrapped" %)
289 289  |=(((
290 290  Parameter
291 291  )))|=(((
... ... @@ -309,7 +309,7 @@
309 309  
310 310  \\
311 311  )))|(% colspan="1" %)(((
312 -chopper at 133 Hz → 3.7 ms
300 +chopper at 133 Hz → 7.7 ms (opening time will be 3.7)
313 313  
314 314  chopper at 66 Hz   → 7.7 ms
315 315  
... ... @@ -338,18 +338,39 @@
338 338  )))|(% colspan="1" %)(((
339 339  200.0 mm   (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>"
340 340  )))
341 -|(% colspan="1" %)(((
342 -Diode voltage
343 -)))|(% colspan="1" %)(((
344 -read out of diode
345 -)))|(% colspan="1" %)(((
346 -**~~ 0 !!! higher values indicate missaligned beam stop!!! 
347 -Call local contact
348 -**
349 -)))
329 +
330 +----
350 350  {{/layout-cell}}
351 351  {{/layout-section}}
352 352  
334 +{{layout-section ac:type="two_equal"}}
335 +{{layout-cell}}
336 +**After data collection/Before entering the exp. hutch:**
337 +
338 +1. Go to "Safety" in kamzik.
339 +1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically:
340 +11. Drive the collimator out
341 +11. Drive the detector back to 1500 mm
342 +1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left).
343 +
344 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png]]
345 +{{/layout-cell}}
346 +
347 +{{layout-cell}}
348 +\\
349 +
350 +\\
351 +
352 +\\
353 +
354 +\\
355 +
356 +\\
357 +
358 +[[image:attach:safety_kamzik.PNG]]
359 +{{/layout-cell}}
360 +{{/layout-section}}
361 +
353 353  {{layout-section ac:type="single"}}
354 354  {{layout-cell}}
355 355  ----
... ... @@ -382,16 +382,41 @@
382 382  * Sample empty?
383 383  * Nozzle or lines clogged? → flush with water, change nozzle
384 384  )))
394 +
395 +\\
396 +
385 385  * (((
386 386  ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Simplonfilewriter/eigerstreamissues"/}}Simplon filewriter/eiger stream issues ====
387 387  
388 388  * First, restart kamzik (server+client) and see if this solves the issue
389 389  * If not, restart the Simplon server (in Astor → haspp11exp03, right click on Simplon/EH.1 and restart)
390 -* If nothing works, kill the Simplon process and then start the server again:
391 -** ssh haspp11exp03
392 -** ps -ef | grep Simplon
393 -** kill -9 simplon_process_id
402 +* (((
403 +If nothing works, kill the Simplon process and then start the server again:* (((
404 +(% class="code" %)
405 +(((
406 +ssh haspp11exp03
394 394  )))
408 +)))
409 +* (((
410 +(% class="code" %)
411 +(((
412 +ps -ef | grep Simplon
413 +)))
414 +)))
415 +* (((
416 +(% class="code" %)
417 +(((
418 +kill -9 simplon_process_id
419 +)))
420 +)))
421 +)))
422 +)))
395 395  {{/layout-cell}}
396 396  {{/layout-section}}
425 +
426 +{{layout-section ac:type="single"}}
427 +{{layout-cell}}
428 +\\
429 +{{/layout-cell}}
430 +{{/layout-section}}
397 397  {{/layout}}