Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -17,7 +17,7 @@ 17 17 18 18 Preparation: 19 19 20 -* filter through 30 µm cell filter (green) into Eppendorf or Falcon (original!) tube 20 +* filter through 30 µm cell filter (green) or 50 µm (yellow) into Eppendorf or Falcon (original!) tube 21 21 22 22 [[image:attach:20211201_095534.jpg||height="250"]] 23 23 ... ... @@ -57,7 +57,7 @@ 57 57 58 58 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ==== 59 59 60 -* Click onthe 'main tape' icon60 +* Click the 'main tape' icon 61 61 * Change the velocity by typing anything from **0.3-3.0 mm/s** 62 62 * Common velocity is 1.0-1.5 mm/s 63 63 * kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. ... ... @@ -66,7 +66,7 @@ 66 66 67 67 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 68 68 69 -* Click an the 'nozzle' icon.69 +* Click on the 'nozzle' icon. 70 70 * ((( 71 71 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 72 72 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. ... ... @@ -214,12 +214,15 @@ 214 214 * (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 215 215 * (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 216 216 ** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 217 -* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 217 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms (technical exposure will always be 7.7 ms, since max. frame rate is 133 Hz 218 +// 218 218 {{/layout-cell}} 219 219 {{/layout-section}} 220 220 221 -{{layout-section ac:type=" two_right_sidebar"}}222 +{{layout-section ac:type="single"}} 222 222 {{layout-cell}} 224 +---- 225 + 223 223 == {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 224 224 225 225 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -233,65 +233,44 @@ 233 233 //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 234 234 235 235 \\ 239 +{{/layout-cell}} 240 +{{/layout-section}} 236 236 242 +{{layout-section ac:type="two_left_sidebar"}} 243 +{{layout-cell}} 237 237 **Check list:** 238 238 239 239 (% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 240 240 241 -(% style="color: rgb(0,0,0);" %)Click " Safety" icon in kamzik.248 +(% style="color: rgb(0,0,0);" %)Click "Run" icon in kamzik. 242 242 243 243 * Put collimator in 244 -** Click "<Call>" next to //collimator_in// 251 +** Put detector distance 200 in //prepare_for_measurement ( ) 252 +// 253 +** Click "<Call>" next to //prepare_for_measurement// 245 245 246 246 \\ 247 247 248 -* Open beam shutter BS1 in //CrystalControl// 249 -{{/layout-cell}} 257 +* Open beam shutter BS1 in //CrystalControl //or// P11 XRayFeed // 250 250 251 -{{layout-cell}} 252 -[[image:attach:kamzik_safety.PNG||height="250"]] 253 -{{/layout-cell}} 254 -{{/layout-section}} 259 +\\ 255 255 256 -{{layout-section ac:type="single"}} 257 -{{layout-cell}} 258 ----- 261 +//**Set run parameters and go 🏃💥**// 259 259 260 -Click "Start/Run" icon in kamzik. 263 +1. Set your desired No. of frames 264 +1. Match exposure time with chopper setting or set desired exposure time 265 +1. Check trigger setting and match to chopper setting 266 +1. To start the run, click "<Call>" next to //start_run (exposure )// 267 +{{/layout-cell}} 261 261 262 -[[image:attach:kamzik_run-tile.jpg||height="400"]] 263 - 264 ----- 269 +{{layout-cell}} 270 +[[image:attach:Kamzik_run(2).PNG]] 265 265 {{/layout-cell}} 266 266 {{/layout-section}} 267 267 268 268 {{layout-section ac:type="two_equal"}} 269 269 {{layout-cell}} 270 -**Set run parameters and go 🏃💥** 271 - 272 -1. Set your desired No. of frames 273 -1. Match exposure time with chopper setting 274 -1. Check trigger setting and match to chopper setting 275 -1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 276 -1. To start the run, click "<Call>" next to //exposure time// 277 - 278 -\\ 279 - 280 -\\ 281 - 282 -**After data collection/Before entering the exp. hutch:** 283 - 284 -1. Go to "Safety" in kamzik. 285 -1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 286 -11. Drive the collimator out 287 -11. Drive the detector back to 1500 mm 288 -1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 289 - 290 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 291 -{{/layout-cell}} 292 - 293 -{{layout-cell}} 294 -(% class="wrapped relative-table" style="width: 100.0%;" %) 276 +(% class="relative-table" %) 295 295 |=((( 296 296 Parameter 297 297 )))|=((( ... ... @@ -315,7 +315,7 @@ 315 315 316 316 \\ 317 317 )))|(% colspan="1" %)((( 318 -chopper at 133 Hz → 3.7 ms300 +chopper at 133 Hz → 7.7 ms (opening time will be 3.7) 319 319 320 320 chopper at 66 Hz → 7.7 ms 321 321 ... ... @@ -344,18 +344,33 @@ 344 344 )))|(% colspan="1" %)((( 345 345 200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 346 346 ))) 347 -|(% colspan="1" %)((( 348 -Diode voltage 349 -)))|(% colspan="1" %)((( 350 -read out of diode 351 -)))|(% colspan="1" %)((( 352 -**~~ 0 !!! higher values indicate missaligned beam stop!!! 353 -Call local contact 354 -** 355 -))) 356 356 {{/layout-cell}} 330 + 331 +{{layout-cell}} 332 +\\ 333 +{{/layout-cell}} 357 357 {{/layout-section}} 358 358 336 +{{layout-section ac:type="two_equal"}} 337 +{{layout-cell}} 338 +**After data collection/Before entering the exp. hutch:** 339 + 340 +1. Go to "Safety" in kamzik. 341 +1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 342 +11. Drive the collimator out 343 +11. Drive the detector back to 1500 mm 344 +1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 345 + 346 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 347 +{{/layout-cell}} 348 + 349 +{{layout-cell}} 350 +[[image:attach:safety_kamzik.PNG]] 351 + 352 +\\ 353 +{{/layout-cell}} 354 +{{/layout-section}} 355 + 359 359 {{layout-section ac:type="single"}} 360 360 {{layout-cell}} 361 361 ----
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -25 01786541 +254729371 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/25 0178654/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/254729371/14. Serial Crystallography: CFEL TapeDrive