Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,7 @@ 1 1 {{layout}} 2 2 {{layout-section ac:type="single"}} 3 3 {{layout-cell}} 4 -[[image:attach:TapeDrive_beschriftet-tile.jpg||height=" 400"]]4 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="250"]] 5 5 6 6 \\ 7 7 ... ... @@ -9,22 +9,18 @@ 9 9 10 10 \\ 11 11 12 ----- 13 - 14 14 == {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** == 15 15 16 -suspension of microcrystals, **at least** 200 µL with 20% crystal density (more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.14 +suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 17 17 18 18 Preparation: 19 19 20 -* filter through 30 µm cell filter (green) or 50 µm (yellow)into Eppendorf or Falcon (original!) tube18 +* filter through 30 µm cell filter (green) into Eppendorf or Falcon (original!) tube 21 21 22 22 [[image:attach:20211201_095534.jpg||height="250"]] 23 23 24 24 \\ 25 25 26 ----- 27 - 28 28 == {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}**14.2 Connecting sample to ElveFlow, sample exchange 29 29 ** == 30 30 ... ... @@ -44,8 +44,6 @@ 44 44 45 45 \\ 46 46 47 ----- 48 - 49 49 == {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}**14.3 TapeDrive operation 50 50 ** == 51 51 ... ... @@ -145,10 +145,8 @@ 145 145 146 146 \\ 147 147 148 -- ---142 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** == 149 149 150 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}}**14.4 Tape roll exchange** == 151 - 152 152 The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 153 153 154 154 * Remove the (almost) empty feeder roll by pulling it upwards. ... ... @@ -156,7 +156,7 @@ 156 156 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 157 157 * Cut the first cm of the new tape roll, directly behind the black sticky part. 158 158 * Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 159 -* Open magnetic tape stabilizer on the **left side**. (% style="color: rgb(255,0,0);" %)//!!!BEAMSTOP!!!//151 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 160 160 * Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 161 161 * Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 162 162 * Attach new tape to the empty roll by using some sticky tape. ... ... @@ -170,17 +170,15 @@ 170 170 171 171 \\ 172 172 173 -** 174 -** 165 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-"/}}** 166 +** === 175 175 {{/layout-cell}} 176 176 {{/layout-section}} 177 177 178 178 {{layout-section ac:type="single"}} 179 179 {{layout-cell}} 180 -- ---172 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Chopper"/}}**14.7 Chopper** == 181 181 182 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}}**14.5 Chopper** == 183 - 184 184 start chopper gui from terminal: 185 185 186 186 (% class="code" %) ... ... @@ -191,7 +191,6 @@ 191 191 (% class="code" %) 192 192 ((( 193 193 python chopperControl.py 194 -\\\\ 195 195 ))) 196 196 {{/layout-cell}} 197 197 {{/layout-section}} ... ... @@ -220,7 +220,7 @@ 220 220 221 221 {{layout-section ac:type="single"}} 222 222 {{layout-cell}} 223 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14. 6Datacollection"/}}**14.6Data collection** ==212 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Datacollection"/}}**14.8 Data collection** == 224 224 225 225 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 226 226 ... ... @@ -230,47 +230,33 @@ 230 230 password: written on control laptop (changes every 6 months) 231 231 ))) 232 232 233 - //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 222 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 234 234 235 235 \\ 225 + 226 +Click "Start" icon in kamzik. 227 + 228 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 229 + 230 +---- 236 236 {{/layout-cell}} 237 237 {{/layout-section}} 238 238 239 -{{layout-section ac:type="two_ left_sidebar"}}234 +{{layout-section ac:type="two_equal"}} 240 240 {{layout-cell}} 241 241 **Check list:** 242 242 243 243 (% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 244 244 245 -(% style="color: rgb(0,0,0);" %)Click "Safety" icon in kamzik. 240 +* Open BS1 (//CrystalControl)// 241 +* Put collimator in (//CrystalControl)// 242 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 243 +* Open fast shutter (//CrystalControl)// 244 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 245 +* Close fast shutter (//CrystalControl)// 246 246 247 -* Put collimator in 248 -** Click "<Call>" next to //collimator_in// 249 - 250 250 \\ 251 251 252 -* Open beam shutter BS1 in //CrystalControl //or// P11 XRayFeed // 253 -{{/layout-cell}} 254 - 255 -{{layout-cell}} 256 -[[image:attach:kamzik_safety.PNG||height="400"]] 257 -{{/layout-cell}} 258 -{{/layout-section}} 259 - 260 -{{layout-section ac:type="single"}} 261 -{{layout-cell}} 262 ----- 263 - 264 -Click "Start/Run" icon in kamzik. 265 - 266 -[[image:attach:kamzik_run-tile.jpg||height="400"]] 267 - 268 ----- 269 -{{/layout-cell}} 270 -{{/layout-section}} 271 - 272 -{{layout-section ac:type="two_equal"}} 273 -{{layout-cell}} 274 274 **Set run parameters and go 🏃💥** 275 275 276 276 1. Set your desired No. of frames ... ... @@ -281,17 +281,19 @@ 281 281 282 282 \\ 283 283 284 - \\259 +(% style="color: rgb(153,51,102);" %)**//Current bug~://** 285 285 286 - **After datacollection/Before enteringthe exp.hutch:**261 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 287 287 288 -1. Go to "Safety" in kamzik. 289 -1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 290 -11. Drive the collimator out 291 -11. Drive the detector back to 1500 mm 292 -1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 293 293 294 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 264 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 265 + 266 +(% class="code" %) 267 +((( 268 + cd /gpfs/current/raw/scan_frames 269 + watch "ls -lrt <run number>/ | tail" 270 +\\\\\\\\ 271 +))) 295 295 {{/layout-cell}} 296 296 297 297 {{layout-cell}} ... ... @@ -364,7 +364,7 @@ 364 364 {{layout-cell}} 365 365 ---- 366 366 367 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14. 7Troubleshooting"/}}**14.7Troubleshooting** ==344 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.9Troubleshooting"/}}**14.9 Troubleshooting** == 368 368 369 369 * ((( 370 370 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== ... ... @@ -392,41 +392,6 @@ 392 392 * Sample empty? 393 393 * Nozzle or lines clogged? → flush with water, change nozzle 394 394 ))) 395 - 396 -\\ 397 - 398 -* ((( 399 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Simplonfilewriter/eigerstreamissues"/}}Simplon filewriter/eiger stream issues ==== 400 - 401 -* First, restart kamzik (server+client) and see if this solves the issue 402 -* If not, restart the Simplon server (in Astor → haspp11exp03, right click on Simplon/EH.1 and restart) 403 -* ((( 404 -If nothing works, kill the Simplon process and then start the server again:* ((( 405 -(% class="code" %) 406 -((( 407 -ssh haspp11exp03 408 -))) 409 -))) 410 -* ((( 411 -(% class="code" %) 412 -((( 413 -ps -ef | grep Simplon 414 -))) 415 -))) 416 -* ((( 417 -(% class="code" %) 418 -((( 419 -kill -9 simplon_process_id 420 -))) 421 -))) 422 -))) 423 -))) 424 424 {{/layout-cell}} 425 425 {{/layout-section}} 426 - 427 -{{layout-section ac:type="single"}} 428 -{{layout-cell}} 429 -\\ 430 -{{/layout-cell}} 431 -{{/layout-section}} 432 432 {{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2 528208791 +236824598 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2 52820879/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824598/14. Serial Crystallography: CFEL TapeDrive