Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -57,7 +57,7 @@ 57 57 58 58 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ==== 59 59 60 -* Click onthe 'main tape' icon60 +* Click the 'main tape' icon 61 61 * Change the velocity by typing anything from **0.3-3.0 mm/s** 62 62 * Common velocity is 1.0-1.5 mm/s 63 63 * kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. ... ... @@ -214,12 +214,15 @@ 214 214 * (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 215 215 * (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 216 216 ** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 217 -* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 217 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms (technical exposure will always be 7.7 ms, since max. frame rate is 133 Hz 218 +// 218 218 {{/layout-cell}} 219 219 {{/layout-section}} 220 220 221 221 {{layout-section ac:type="single"}} 222 222 {{layout-cell}} 224 +---- 225 + 223 223 == {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 224 224 225 225 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -242,60 +242,35 @@ 242 242 243 243 (% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 244 244 245 -(% style="color: rgb(0,0,0);" %)Click " Safety" icon in kamzik.248 +(% style="color: rgb(0,0,0);" %)Click "Run" icon in kamzik. 246 246 247 247 * Put collimator in 248 -** Click "<Call>" next to //collimator_in// 251 +** Put detector distance 200 in //prepare_for_measurement ( ) 252 +// 253 +** Click "<Call>" next to //prepare_for_measurement// 249 249 250 250 \\ 251 251 252 252 * Open beam shutter BS1 in //CrystalControl //or// P11 XRayFeed // 253 -{{/layout-cell}} 254 254 255 -{{layout-cell}} 256 -[[image:attach:kamzik_safety.PNG||height="400"]] 257 -{{/layout-cell}} 258 -{{/layout-section}} 259 +\\ 259 259 260 -{{layout-section ac:type="single"}} 261 -{{layout-cell}} 262 ----- 261 +//**Set run parameters and go 🏃💥**// 263 263 264 -Click "Start/Run" icon in kamzik. 263 +1. Set your desired No. of frames 264 +1. Match exposure time with chopper setting or set desired exposure time 265 +1. Check trigger setting and match to chopper setting 266 +1. To start the run, click "<Call>" next to //start_run (exposure )// 267 +{{/layout-cell}} 265 265 266 -[[image:attach:kamzik_run-tile.jpg||height="400"]] 267 - 268 ----- 269 +{{layout-cell}} 270 +[[image:attach:Kamzik_run(2).PNG]] 269 269 {{/layout-cell}} 270 270 {{/layout-section}} 271 271 272 272 {{layout-section ac:type="two_equal"}} 273 273 {{layout-cell}} 274 -**Set run parameters and go 🏃💥** 275 - 276 -1. Set your desired No. of frames 277 -1. Match exposure time with chopper setting 278 -1. Check trigger setting and match to chopper setting 279 -1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 280 -1. To start the run, click "<Call>" next to //exposure time// 281 - 282 -\\ 283 - 284 -\\ 285 - 286 -**After data collection/Before entering the exp. hutch:** 287 - 288 -1. Go to "Safety" in kamzik. 289 -1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 290 -11. Drive the collimator out 291 -11. Drive the detector back to 1500 mm 292 -1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 293 - 294 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 295 -{{/layout-cell}} 296 - 297 -{{layout-cell}} 298 -(% class="wrapped relative-table" style="width: 100.0%;" %) 276 +(% class="relative-table wrapped" %) 299 299 |=((( 300 300 Parameter 301 301 )))|=((( ... ... @@ -319,7 +319,7 @@ 319 319 320 320 \\ 321 321 )))|(% colspan="1" %)((( 322 -chopper at 133 Hz → 3.7 ms300 +chopper at 133 Hz → 7.7 ms (opening time will be 3.7) 323 323 324 324 chopper at 66 Hz → 7.7 ms 325 325 ... ... @@ -348,18 +348,37 @@ 348 348 )))|(% colspan="1" %)((( 349 349 200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 350 350 ))) 351 -|(% colspan="1" %)((( 352 -Diode voltage 353 -)))|(% colspan="1" %)((( 354 -read out of diode 355 -)))|(% colspan="1" %)((( 356 -**~~ 0 !!! higher values indicate missaligned beam stop!!! 357 -Call local contact 358 -** 359 -))) 360 360 {{/layout-cell}} 330 + 331 +{{layout-cell}} 332 +\\ 333 +{{/layout-cell}} 361 361 {{/layout-section}} 362 362 336 +{{layout-section ac:type="two_equal"}} 337 +{{layout-cell}} 338 +---- 339 + 340 +**After data collection/Before entering the exp. hutch:** 341 + 342 +1. Go to "Safety" in kamzik. 343 +1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 344 +11. Drive the collimator out 345 +11. Drive the detector back to 1500 mm 346 +1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 347 + 348 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png]] 349 +{{/layout-cell}} 350 + 351 +{{layout-cell}} 352 +---- 353 + 354 +[[image:attach:safety_kamzik.PNG]] 355 + 356 +\\ 357 +{{/layout-cell}} 358 +{{/layout-section}} 359 + 363 363 {{layout-section ac:type="single"}} 364 364 {{layout-cell}} 365 365 ----
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -252 8260061 +254729372 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/252 826006/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/254729372/14. Serial Crystallography: CFEL TapeDrive