Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -57,7 +57,7 @@ 57 57 58 58 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ==== 59 59 60 -* Click the 'main tape' icon 60 +* Click on the 'main tape' icon 61 61 * Change the velocity by typing anything from **0.3-3.0 mm/s** 62 62 * Common velocity is 1.0-1.5 mm/s 63 63 * kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. ... ... @@ -66,7 +66,7 @@ 66 66 67 67 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 68 68 69 -* Click on the 'nozzle' icon.69 +* Click an the 'nozzle' icon. 70 70 * ((( 71 71 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 72 72 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. ... ... @@ -214,8 +214,7 @@ 214 214 * (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 215 215 * (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 216 216 ** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 217 -* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms (technical exposure will always be 7.7 ms, since max. frame rate is 133 Hz 218 -// 217 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 219 219 {{/layout-cell}} 220 220 {{/layout-section}} 221 221 ... ... @@ -243,12 +243,10 @@ 243 243 244 244 (% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 245 245 246 -(% style="color: rgb(0,0,0);" %)Click " Run" icon in kamzik.245 +(% style="color: rgb(0,0,0);" %)Click "Safety" icon in kamzik. 247 247 248 248 * Put collimator in 249 -** Put detector distance 200 in //prepare_for_measurement ( ) 250 -// 251 -** Click "<Call>" next to //prepare_for_measurement// 248 +** Click "<Call>" next to //collimator_in// 252 252 253 253 \\ 254 254 ... ... @@ -264,6 +264,8 @@ 264 264 {{layout-cell}} 265 265 ---- 266 266 264 +Click "Start/Run" icon in kamzik. 265 + 267 267 [[image:attach:kamzik_run-tile.jpg||height="400"]] 268 268 269 269 ---- ... ... @@ -275,10 +275,10 @@ 275 275 **Set run parameters and go 🏃💥** 276 276 277 277 1. Set your desired No. of frames 278 -1. Match exposure time with chopper setting or set desired exposure time277 +1. Match exposure time with chopper setting 279 279 1. Check trigger setting and match to chopper setting 280 -1. To start therun,click "<Call>"nextto//start_run(exposure)281 -// 279 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 280 +1. To start the run, click "<Call>" next to //exposure time// 282 282 283 283 \\ 284 284 ... ... @@ -320,7 +320,7 @@ 320 320 321 321 \\ 322 322 )))|(% colspan="1" %)((( 323 -chopper at 133 Hz → 7.7 ms(opening time will be 3.7)322 +chopper at 133 Hz → 3.7 ms 324 324 325 325 chopper at 66 Hz → 7.7 ms 326 326 ... ... @@ -349,6 +349,15 @@ 349 349 )))|(% colspan="1" %)((( 350 350 200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 351 351 ))) 351 +|(% colspan="1" %)((( 352 +Diode voltage 353 +)))|(% colspan="1" %)((( 354 +read out of diode 355 +)))|(% colspan="1" %)((( 356 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 357 +Call local contact 358 +** 359 +))) 352 352 {{/layout-cell}} 353 353 {{/layout-section}} 354 354
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -25 47293681 +252826005 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/25 4729368/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/252826005/14. Serial Crystallography: CFEL TapeDrive