Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,33 +1,79 @@ 1 1 {{layout}} 2 2 {{layout-section ac:type="single"}} 3 3 {{layout-cell}} 4 -[[image:attach:TapeDrive_beschriftet-tile.jpg||height=" 400"]]4 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="250"]] 5 5 6 6 \\ 7 7 8 - {{toc minLevel="2"/}}8 +\\ 9 9 10 10 \\ 11 11 12 -- ---12 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1RevertfromCrystallographytoTapeDrive(P11staff/CFEL)"/}}**14.1 Revert from Crystallography to TapeDrive (P11 staff/CFEL)** === 13 13 14 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** == 14 +* remove vortex 15 +* beamstop to out-position? 16 +* remove goniometer. The airbearing should be stopped (p11/servermotor/eh.1.01) 17 +* move cryojet out of the way, ramp the cryo up and shut it down. Close the compressed air to the shield flow. The biggest cable kinks and needs to be disconnected. 18 +* stop refill of the robot dewar and empty the dewar, warm up. 19 +* Disable backlight (unplug Festo connection). (% style="color: rgb(255,0,0);" %)//Is this still needed?// 20 +* (% style="color: rgb(0,0,0);" %)mount the 10 um diode and connect (via connector on the granite). This is connected to the leftmost Keithly (power up, check that settings are gain E06, Filter on, Rise time 1 ms. Keithly is connected to the oscilloscope and the delay generator, delay generator is connected to oscilloscope and detector, see diagram in P11 wiki. (% style="color: rgb(0, 0, 0); color: rgb(255, 0, 0)" %)//Insert here the setting for oscilloscope//(% style="color: rgb(0,0,0);" %)//. //Make sure to connect the multi-trigger to the back of the detector instead of the standard trigger, when starting to use the chopper (pull the thin ring with ‘grip’ area to detach). Cables are labeled. Make sure before using the chopper that the channels are enabled. 21 +* (% style="color: rgb(0,0,0);" %)move goniotower to X ~~ 17 000 15 15 16 -s uspension ofmicrocrystals,**at least**200µLwith20%crystaldensity(moreisalwaysbetter),size range:2-30µm,**tip:** bringsomemother liquor forwashing,filtering,dilutingetc.23 +(% style="color: rgb(0,0,0);" %)Mounting of the TapeDrive is done by the CFEL group. Electronics and control units are combined on a small shelf, that requires only one power and network plug-in. The shelf will be placed left-sided (looking upstream) to the detector tower. The ElveFlow and control laptop as well as several necessary consumables are placed on a cart, which is to be positioned on the right (looking upstream) against the robot platform. The CFEL chiller is placed on the right of the platform and connected to the TapeDrive GASnozzle. 17 17 25 +\\ 26 + 27 +* adjust focus of the tape by moving X in goniometer tower until you see it in the overview camera. Final adjustment should be done when there is flow. Latest value is about 4500 in X and also 5000 in Z (higher soft limit changed from 2976,63 to 6000). (% style="color: rgb(255,0,0);" %)//Better to use the back illumination in the GUI to focus the tape - old instruction, not sure if this is the case. Back illumination is the external light source in the detector tower (the crystallography backlight should be disable for tapedrive).// 28 +* (% style="color: rgb(0,0,0);" %)Check the Minimum Detector Distance; the detector should not collide with the tapedrive while driven to 154 mm but it has to be verified. Also check that all cables and capillaries are taped away when the users start, so that nothing protrudes further than the tapedrive itself. Soft limit can be edited in eh.3.11 Atk panel. 29 +* (% style="color: rgb(0,0,0);" %)Reconfirm the alignment of the beamstop, once everything, including the nozzle, is in place. Modify config.ini for beamstop in- and out-position to both mach in (27 000). This way the beamstop will not be driven out when the hutch is opened, to avoid that the users forget to drive it in when restarting after entering the hutch. 30 + 31 +\\ 32 + 33 +Prepare necessary controls for data collection: 34 + 35 +* ATK panels: 36 +** p11/simplon_filewriter/eh.01 37 +** p11/simplon_detector/eh.01 38 +*** count time = 0.0075 39 +*** trigger (**ints **if working without the chopper, # or triggers is 1, **exts** if with the chopper, # or triggers = number of images). Exts is also the standard trigger in normal crystallography. If GUI is used to take images (e.g. for beamstop alignment) the trigger mode will be forced by that and needs to be reverted manually for the users to continue. 40 +*** numer of images = 100 000 41 +*** number of images in container = 1000 42 +*** mode 16m/4M 43 +*** detector distance = 200 mm (usually) 44 +** p11/detectortower 45 +** p11/motor/eh.09 46 +* remote access to TapeDrive control laptop: 47 +** open terminal, execute command: xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 48 + password: //written on control laptop 49 +// 50 +* Cameras: 51 +** haspp11ethcam1 → detector tower camera to monitor nozzle 52 +** haspp11ethcam4 → goniometer camera to monitor tape from above 53 +* OnDa (on haspp11user04): 54 +//This starts both GUIs (Frame Viewer & Crystallography GUI) and onda-monitor, the server component. The tool has a bunch of parameters which you can list with ./onda-runner.py —help.//\\ 55 +** 16M mode → cd /home/p11user/CfelSoft/202103_onda 56 + ./onda-runner.py onda-config/onda-config-Eiger16M.toml 57 +** 4M mode → cd /home/p11user/CfelSoft/202103_onda 58 + ./onda-runner.py onda-config/onda-config-Eiger4M.toml\\ 59 + 60 +\\ 61 + 62 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2Samplecharacteristicsandpreparation"/}}**14.2 Sample characteristics and preparation** === 63 + 64 +suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 65 + 18 18 Preparation: 19 19 20 -* filter through 30 µm cell filter (green) or 50 µm (yellow)into Eppendorf or Falcon (original!) tube68 +* filter through 30 µm cell filter (green) into Eppendorf or Falcon (original!) tube 21 21 22 22 [[image:attach:20211201_095534.jpg||height="250"]] 23 23 24 24 \\ 25 25 26 ----- 74 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3ConnectingsampletoElveFlow,sampleexchange"/}}**14.3 Connecting sample to ElveFlow, sample exchange 75 +** === 27 27 28 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}**14.2 Connecting sample to ElveFlow, sample exchange 29 -** == 30 - 31 31 After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 32 32 33 33 Be aware to which channel and nozzle line your sample is connected. ... ... @@ -44,11 +44,9 @@ 44 44 45 45 \\ 46 46 47 ----- 93 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4TapeDriveoperation"/}}**14.4 TapeDrive operation 94 +** === 48 48 49 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}**14.3 TapeDrive operation 50 -** == 51 - 52 52 The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 53 53 Now start the client. Same thing, a terminal will open, shortly after a small window. 54 54 ... ... @@ -55,9 +55,9 @@ 55 55 Click 'Devices' in the **client session** to open the control window. 56 56 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 57 57 58 - ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape**====102 +**Tape** 59 59 60 -* Click the 'main tape' icon 104 +* Click on the 'main tape' icon 61 61 * Change the velocity by typing anything from **0.3-3.0 mm/s** 62 62 * Common velocity is 1.0-1.5 mm/s 63 63 * kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. ... ... @@ -66,7 +66,7 @@ 66 66 67 67 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 68 68 69 -* Click on the 'nozzle' icon.113 +* Click an the 'nozzle' icon. 70 70 * ((( 71 71 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 72 72 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. ... ... @@ -145,10 +145,8 @@ 145 145 146 146 \\ 147 147 148 -- ---192 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Taperollexchange"/}}**14.5 Tape roll exchange** === 149 149 150 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}}**14.4 Tape roll exchange** == 151 - 152 152 The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 153 153 154 154 * Remove the (almost) empty feeder roll by pulling it upwards. ... ... @@ -156,7 +156,7 @@ 156 156 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 157 157 * Cut the first cm of the new tape roll, directly behind the black sticky part. 158 158 * Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 159 -* Open magnetic tape stabilizer on the **left side**. (% style="color: rgb(255,0,0);" %)//!!!BEAMSTOP!!!//201 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 160 160 * Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 161 161 * Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 162 162 * Attach new tape to the empty roll by using some sticky tape. ... ... @@ -170,17 +170,15 @@ 170 170 171 171 \\ 172 172 173 -** 174 -** 215 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-"/}}** 216 +** === 175 175 {{/layout-cell}} 176 176 {{/layout-section}} 177 177 178 178 {{layout-section ac:type="single"}} 179 179 {{layout-cell}} 180 -- ---222 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Chopper"/}}**14.7 Chopper** === 181 181 182 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}}**14.5 Chopper** == 183 - 184 184 start chopper gui from terminal: 185 185 186 186 (% class="code" %) ... ... @@ -191,7 +191,6 @@ 191 191 (% class="code" %) 192 192 ((( 193 193 python chopperControl.py 194 -\\\\ 195 195 ))) 196 196 {{/layout-cell}} 197 197 {{/layout-section}} ... ... @@ -214,14 +214,13 @@ 214 214 * (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 215 215 * (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 216 216 ** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 217 -* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms (technical exposure will always be 7.7 ms, since max. frame rate is 133 Hz 218 -// 256 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 219 219 {{/layout-cell}} 220 220 {{/layout-section}} 221 221 222 222 {{layout-section ac:type="single"}} 223 223 {{layout-cell}} 224 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14. 6Datacollection"/}}**14.6Data collection** ==262 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.8Datacollection"/}}**14.8 Data collection** === 225 225 226 226 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 227 227 ... ... @@ -231,47 +231,60 @@ 231 231 password: written on control laptop (changes every 6 months) 232 232 ))) 233 233 234 - //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 272 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 235 235 236 236 \\ 275 + 276 +Click "Start" icon in kamzik. 277 + 278 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 279 + 280 +---- 237 237 {{/layout-cell}} 238 238 {{/layout-section}} 239 239 240 -{{layout-section ac:type="two_ left_sidebar"}}284 +{{layout-section ac:type="two_equal"}} 241 241 {{layout-cell}} 242 242 **Check list:** 243 243 244 244 (% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 245 245 246 -(% style="color: rgb(0,0,0);" %)Click "Run" icon in kamzik. 290 +* Open BS1 (//CrystalControl)// 291 +* Put collimator in (//CrystalControl)// 292 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 293 +* Open fast shutter (//CrystalControl)// 294 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 295 +* Close fast shutter (//CrystalControl)// 247 247 248 -* Put collimator in 249 -** Put detector distance 200 in //prepare_for_measurement ( ) 250 -// 251 -** Click "<Call>" next to //prepare_for_measurement// 252 - 253 253 \\ 254 254 255 -* OpenbeamshutterBS1 in //CrystalControl//or//P11 XRayFeed //299 +**Set run parameters and go 🏃💥** 256 256 301 +1. Set your desired No. of frames 302 +1. Match exposure time with chopper setting 303 +1. Check trigger setting and match to chopper setting 304 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 305 +1. To start the run, click "<Call>" next to //exposure time// 306 + 257 257 \\ 258 258 259 - //**Setrun parametersandgo🏃💥**//309 +(% style="color: rgb(153,51,102);" %)**//Current bug~://** 260 260 261 -1. Set your desired No. of frames 262 -1. Match exposure time with chopper setting or set desired exposure time 263 -1. Check trigger setting and match to chopper setting 264 -1. To start the run, click "<Call>" next to //start_run (exposure )// 265 -{{/layout-cell}} 311 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 266 266 267 -{{layout-cell}} 268 -[[image:attach:Kamzik_run(2).PNG||height="400"]] 313 + 314 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 315 + 316 +(% class="code" %) 317 +((( 318 + cd /gpfs/current/raw/scan_frames 319 + watch "ls -lrt <run number>/ | tail" 320 +\\\\\\\\ 321 +))) 269 269 {{/layout-cell}} 270 -{{/layout-section}} 271 271 272 -{{layout-section ac:type="two_equal"}} 273 273 {{layout-cell}} 274 -(% class="relative-table" %) 325 +(% class="wrapped relative-table" style="width: 100.0%;" %) 275 275 |=((( 276 276 Parameter 277 277 )))|=((( ... ... @@ -295,7 +295,7 @@ 295 295 296 296 \\ 297 297 )))|(% colspan="1" %)((( 298 -chopper at 133 Hz → 7.7 ms(opening time will be 3.7)349 +chopper at 133 Hz → 3.7 ms 299 299 300 300 chopper at 66 Hz → 7.7 ms 301 301 ... ... @@ -324,19 +324,16 @@ 324 324 )))|(% colspan="1" %)((( 325 325 200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 326 326 ))) 378 +|(% colspan="1" %)((( 379 +Diode voltage 380 +)))|(% colspan="1" %)((( 381 +read out of diode 382 +)))|(% colspan="1" %)((( 383 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 384 +Call local contact 385 +** 386 +))) 327 327 {{/layout-cell}} 328 - 329 -{{layout-cell}} 330 -**After data collection/Before entering the exp. hutch:** 331 - 332 -1. Go to "Safety" in kamzik. 333 -1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 334 -11. Drive the collimator out 335 -11. Drive the detector back to 1500 mm 336 -1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 337 - 338 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 339 -{{/layout-cell}} 340 340 {{/layout-section}} 341 341 342 342 {{layout-section ac:type="single"}} ... ... @@ -343,7 +343,7 @@ 343 343 {{layout-cell}} 344 344 ---- 345 345 346 -== {{id name="14.SerialCrystallography:CFELTapeDrive-14. 7Troubleshooting"/}}**14.7Troubleshooting**==394 +=== {{id name="14.SerialCrystallography:CFELTapeDrive-14.9Troubleshooting"/}}14.9 Troubleshooting === 347 347 348 348 * ((( 349 349 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== ... ... @@ -371,41 +371,6 @@ 371 371 * Sample empty? 372 372 * Nozzle or lines clogged? → flush with water, change nozzle 373 373 ))) 374 - 375 -\\ 376 - 377 -* ((( 378 -==== {{id name="14.SerialCrystallography:CFELTapeDrive-Simplonfilewriter/eigerstreamissues"/}}Simplon filewriter/eiger stream issues ==== 379 - 380 -* First, restart kamzik (server+client) and see if this solves the issue 381 -* If not, restart the Simplon server (in Astor → haspp11exp03, right click on Simplon/EH.1 and restart) 382 -* ((( 383 -If nothing works, kill the Simplon process and then start the server again:* ((( 384 -(% class="code" %) 385 -((( 386 -ssh haspp11exp03 387 -))) 388 -))) 389 -* ((( 390 -(% class="code" %) 391 -((( 392 -ps -ef | grep Simplon 393 -))) 394 -))) 395 -* ((( 396 -(% class="code" %) 397 -((( 398 -kill -9 simplon_process_id 399 -))) 400 -))) 401 -))) 402 -))) 403 403 {{/layout-cell}} 404 404 {{/layout-section}} 405 - 406 -{{layout-section ac:type="single"}} 407 -{{layout-cell}} 408 -\\ 409 -{{/layout-cell}} 410 -{{/layout-section}} 411 411 {{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2 547293701 +236824593 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2 54729370/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/236824593/14. Serial Crystallography: CFEL TapeDrive