Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -221,6 +221,8 @@ 221 221 222 222 {{layout-section ac:type="single"}} 223 223 {{layout-cell}} 224 +---- 225 + 224 224 == {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 225 225 226 226 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -245,10 +245,12 @@ 245 245 246 246 (% style="color: rgb(0,0,0);" %)Click "Run" icon in kamzik. 247 247 248 -* Put collimator in 249 -** Put detector distance 200 in //prepare_for_measurement ( ) 250 +* Put detector distance 200 in //prepare_for_measurement ( ) 250 250 // 251 -** Click "<Call>" next to //prepare_for_measurement// 252 +* Click "<Call>" next to //prepare_for_measurement 253 +//This will:\\ 254 +** drive the collimator in //IN// position 255 +** drive detector to 200 mm 252 252 253 253 \\ 254 254 ... ... @@ -261,17 +261,20 @@ 261 261 1. Set your desired No. of frames 262 262 1. Match exposure time with chopper setting or set desired exposure time 263 263 1. Check trigger setting and match to chopper setting 268 +no chopper → external triffer //off 269 +// chopper → external trigger// on 270 +// 264 264 1. To start the run, click "<Call>" next to //start_run (exposure )// 265 265 {{/layout-cell}} 266 266 267 267 {{layout-cell}} 268 -[[image:attach:Kamzik_run(2).PNG ||height="400"]]275 +[[image:attach:Kamzik_run(2).PNG]] 269 269 {{/layout-cell}} 270 270 {{/layout-section}} 271 271 272 -{{layout-section ac:type=" two_equal"}}279 +{{layout-section ac:type="single"}} 273 273 {{layout-cell}} 274 -(% class="relative-table" %) 281 +(% class="relative-table wrapped" style="width: 55.9569%;" %) 275 275 |=((( 276 276 Parameter 277 277 )))|=((( ... ... @@ -282,7 +282,7 @@ 282 282 |((( 283 283 Images number 284 284 )))|((( 285 - Setnumber of frames you want to collect292 +number of frames you want to collect 286 286 )))|(% colspan="1" %)((( 287 287 usually 100k - 200k, but adjust according to hitrate 288 288 ... ... @@ -317,15 +317,12 @@ 317 317 )))|(% colspan="1" %)((( 318 318 \\ 319 319 ))) 320 -|(% colspan="1" %)((( 321 -move_detector (distance) 322 -)))|(% colspan="1" %)((( 323 -Set detector distance 324 -)))|(% colspan="1" %)((( 325 -200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 326 -))) 327 + 328 +---- 327 327 {{/layout-cell}} 330 +{{/layout-section}} 328 328 332 +{{layout-section ac:type="two_equal"}} 329 329 {{layout-cell}} 330 330 **After data collection/Before entering the exp. hutch:** 331 331 ... ... @@ -335,8 +335,22 @@ 335 335 11. Drive the detector back to 1500 mm 336 336 1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 337 337 338 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png ||height="400"]]342 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png]] 339 339 {{/layout-cell}} 344 + 345 +{{layout-cell}} 346 +\\ 347 + 348 +\\ 349 + 350 +\\ 351 + 352 +\\ 353 + 354 +\\ 355 + 356 +[[image:attach:safety_kamzik.PNG]] 357 +{{/layout-cell}} 340 340 {{/layout-section}} 341 341 342 342 {{layout-section ac:type="single"}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2 547293701 +281980768 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2 54729370/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/281980768/14. Serial Crystallography: CFEL TapeDrive