... ... @@ -221,6 +221,8 @@
221 221  
222 222  {{layout-section ac:type="single"}}
223 223  {{layout-cell}}
224 +----
225 +
224 224  == {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** ==
225 225  
226 226  Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
... ... @@ -245,10 +245,12 @@
245 245  
246 246  (% style="color: rgb(0,0,0);" %)Click "Run" icon in kamzik.
247 247  
248 -* Put collimator in
249 -** Put detector distance 200 in //prepare_for_measurement (      )
250 +* Put detector distance 200 in //prepare_for_measurement (      )
250 250  //
251 -** Click "<Call>" next to //prepare_for_measurement//
252 +* Click "<Call>" next to //prepare_for_measurement
253 +//This will:\\
254 +** drive the collimator in //IN// position
255 +** drive detector to 200 mm
252 252  
253 253  \\
254 254  
... ... @@ -261,17 +261,20 @@
261 261  1. Set your desired No. of frames
262 262  1. Match exposure time with chopper setting or set desired exposure time
263 263  1. Check trigger setting and match to chopper setting
268 +no chopper → external triffer //off
269 +// chopper → external trigger// on
270 +//
264 264  1. To start the run, click "<Call>" next to //start_run (exposure    )//
265 265  {{/layout-cell}}
266 266  
267 267  {{layout-cell}}
268 -[[image:attach:Kamzik_run(2).PNG||height="400"]]
275 +[[image:attach:Kamzik_run(2).PNG]]
269 269  {{/layout-cell}}
270 270  {{/layout-section}}
271 271  
272 -{{layout-section ac:type="two_equal"}}
279 +{{layout-section ac:type="single"}}
273 273  {{layout-cell}}
274 -(% class="relative-table" %)
281 +(% class="relative-table wrapped" style="width: 55.9569%;" %)
275 275  |=(((
276 276  Parameter
277 277  )))|=(((
... ... @@ -282,7 +282,7 @@
282 282  |(((
283 283  Images number
284 284  )))|(((
285 -Set number of frames you want to collect
292 +number of frames you want to collect
286 286  )))|(% colspan="1" %)(((
287 287  usually 100k - 200k, but adjust according to hitrate
288 288  
... ... @@ -317,15 +317,12 @@
317 317  )))|(% colspan="1" %)(((
318 318  \\
319 319  )))
320 -|(% colspan="1" %)(((
321 -move_detector (distance)
322 -)))|(% colspan="1" %)(((
323 -Set detector distance
324 -)))|(% colspan="1" %)(((
325 -200.0 mm   (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>"
326 -)))
327 +
328 +----
327 327  {{/layout-cell}}
330 +{{/layout-section}}
328 328  
332 +{{layout-section ac:type="two_equal"}}
329 329  {{layout-cell}}
330 330  **After data collection/Before entering the exp. hutch:**
331 331  
... ... @@ -335,8 +335,22 @@
335 335  11. Drive the detector back to 1500 mm
336 336  1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left).
337 337  
338 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]]
342 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png]]
339 339  {{/layout-cell}}
344 +
345 +{{layout-cell}}
346 +\\
347 +
348 +\\
349 +
350 +\\
351 +
352 +\\
353 +
354 +\\
355 +
356 +[[image:attach:safety_kamzik.PNG]]
357 +{{/layout-cell}}
340 340  {{/layout-section}}
341 341  
342 342  {{layout-section ac:type="single"}}
Confluence.Code.ConfluencePageClass[0]
Id
... ... @@ -1,1 +1,1 @@
1 -254729370
1 +281980768
URL
... ... @@ -1,1 +1,1 @@
1 -https://confluence.desy.de/spaces/11/pages/254729370/14. Serial Crystallography: CFEL TapeDrive
1 +https://confluence.desy.de/spaces/11/pages/281980768/14. Serial Crystallography: CFEL TapeDrive