Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,7 @@ 1 1 {{layout}} 2 2 {{layout-section ac:type="single"}} 3 3 {{layout-cell}} 4 -[[image:attach:TapeDrive_beschriftet-tile.jpg||height=" 400"]]4 +[[image:attach:TapeDrive_beschriftet-tile.jpg||height="250"]] 5 5 6 6 \\ 7 7 ... ... @@ -13,11 +13,11 @@ 13 13 14 14 == {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** == 15 15 16 -suspension of microcrystals, **at least** 200 µL with 20% crystal density (more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.16 +suspension of microcrystals, **at least** 200 µL with 20% crystal density(more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 17 17 18 18 Preparation: 19 19 20 -* filter through 30 µm cell filter (green) or 50 µm (yellow)into Eppendorf or Falcon (original!) tube20 +* filter through 30 µm cell filter (green) into Eppendorf or Falcon (original!) tube 21 21 22 22 [[image:attach:20211201_095534.jpg||height="250"]] 23 23 ... ... @@ -57,7 +57,7 @@ 57 57 58 58 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ==== 59 59 60 -* Click the 'main tape' icon 60 +* Click on the 'main tape' icon 61 61 * Change the velocity by typing anything from **0.3-3.0 mm/s** 62 62 * Common velocity is 1.0-1.5 mm/s 63 63 * kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. ... ... @@ -66,7 +66,7 @@ 66 66 67 67 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 68 68 69 -* Click on the 'nozzle' icon.69 +* Click an the 'nozzle' icon. 70 70 * ((( 71 71 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 72 72 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. ... ... @@ -156,7 +156,7 @@ 156 156 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 157 157 * Cut the first cm of the new tape roll, directly behind the black sticky part. 158 158 * Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 159 -* Open magnetic tape stabilizer on the **left side**. (% style="color: rgb(255,0,0);" %)//!!!BEAMSTOP!!!//159 +* Open magnetic tape stabilizer on the **left side**. //!!!BEAMSTOP!!!// 160 160 * Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 161 161 * Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 162 162 * Attach new tape to the empty roll by using some sticky tape. ... ... @@ -214,8 +214,7 @@ 214 214 * (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 215 215 * (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 216 216 ** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 217 -* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms (technical exposure will always be 7.7 ms, since max. frame rate is 133 Hz 218 -// 217 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 219 219 {{/layout-cell}} 220 220 {{/layout-section}} 221 221 ... ... @@ -233,47 +233,60 @@ 233 233 password: written on control laptop (changes every 6 months) 234 234 ))) 235 235 236 - //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 235 + //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 237 237 238 238 \\ 238 + 239 +Click "Start" icon in kamzik. 240 + 241 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 242 + 243 +---- 239 239 {{/layout-cell}} 240 240 {{/layout-section}} 241 241 242 -{{layout-section ac:type="two_ left_sidebar"}}247 +{{layout-section ac:type="two_equal"}} 243 243 {{layout-cell}} 244 244 **Check list:** 245 245 246 246 (% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 247 247 248 -(% style="color: rgb(0,0,0);" %)Click "Run" icon in kamzik. 253 +* Open BS1 (//CrystalControl)// 254 +* Put collimator in (//CrystalControl)// 255 +* Check beamstop position = 27 000 (//Atk panel p11/motor/eh.3.09)// 256 +* Open fast shutter (//CrystalControl)// 257 +* Check diode voltage ~~ 0.0 (//kamzik Run/Diode voltage)// 258 +* Close fast shutter (//CrystalControl)// 249 249 250 -* Put collimator in 251 -** Put detector distance 200 in //prepare_for_measurement ( ) 252 -// 253 -** Click "<Call>" next to //prepare_for_measurement// 254 - 255 255 \\ 256 256 257 -* OpenbeamshutterBS1 in //CrystalControl//or//P11 XRayFeed //262 +**Set run parameters and go 🏃💥** 258 258 264 +1. Set your desired No. of frames 265 +1. Match exposure time with chopper setting 266 +1. Check trigger setting and match to chopper setting 267 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 268 +1. To start the run, click "<Call>" next to //exposure time// 269 + 259 259 \\ 260 260 261 - //**Setrun parametersandgo🏃💥**//272 +(% style="color: rgb(153,51,102);" %)**//Current bug~://** 262 262 263 -1. Set your desired No. of frames 264 -1. Match exposure time with chopper setting or set desired exposure time 265 -1. Check trigger setting and match to chopper setting 266 -1. To start the run, click "<Call>" next to //start_run (exposure )// 267 -{{/layout-cell}} 274 +(% style="color: rgb(0,0,0);" %)You need to "Stop" run in kamzik manually after all images have been acquired. This moves the shield up and closes the fast shutter. Afterwards you can start a new run by clicking "<Call>". 268 268 269 -{{layout-cell}} 270 -[[image:attach:Kamzik_run(2).PNG]] 276 + 277 +(% style="color: rgb(0,0,0);" %)Check progress in terminal with: 278 + 279 +(% class="code" %) 280 +((( 281 + cd /gpfs/current/raw/scan_frames 282 + watch "ls -lrt <run number>/ | tail" 283 +\\\\\\\\ 284 +))) 271 271 {{/layout-cell}} 272 -{{/layout-section}} 273 273 274 -{{layout-section ac:type="two_equal"}} 275 275 {{layout-cell}} 276 -(% class="relative-table" %) 288 +(% class="wrapped relative-table" style="width: 100.0%;" %) 277 277 |=((( 278 278 Parameter 279 279 )))|=((( ... ... @@ -297,7 +297,7 @@ 297 297 298 298 \\ 299 299 )))|(% colspan="1" %)((( 300 -chopper at 133 Hz → 7.7 ms(opening time will be 3.7)312 +chopper at 133 Hz → 3.7 ms 301 301 302 302 chopper at 66 Hz → 7.7 ms 303 303 ... ... @@ -326,33 +326,18 @@ 326 326 )))|(% colspan="1" %)((( 327 327 200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 328 328 ))) 341 +|(% colspan="1" %)((( 342 +Diode voltage 343 +)))|(% colspan="1" %)((( 344 +read out of diode 345 +)))|(% colspan="1" %)((( 346 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 347 +Call local contact 348 +** 349 +))) 329 329 {{/layout-cell}} 330 - 331 -{{layout-cell}} 332 -\\ 333 -{{/layout-cell}} 334 334 {{/layout-section}} 335 335 336 -{{layout-section ac:type="two_equal"}} 337 -{{layout-cell}} 338 -**After data collection/Before entering the exp. hutch:** 339 - 340 -1. Go to "Safety" in kamzik. 341 -1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 342 -11. Drive the collimator out 343 -11. Drive the detector back to 1500 mm 344 -1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 345 - 346 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 347 -{{/layout-cell}} 348 - 349 -{{layout-cell}} 350 -[[image:attach:safety_kamzik.PNG]] 351 - 352 -\\ 353 -{{/layout-cell}} 354 -{{/layout-section}} 355 - 356 356 {{layout-section ac:type="single"}} 357 357 {{layout-cell}} 358 358 ---- ... ... @@ -385,41 +385,16 @@ 385 385 * Sample empty? 386 386 * Nozzle or lines clogged? → flush with water, change nozzle 387 387 ))) 388 - 389 -\\ 390 - 391 391 * ((( 392 392 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Simplonfilewriter/eigerstreamissues"/}}Simplon filewriter/eiger stream issues ==== 393 393 394 394 * First, restart kamzik (server+client) and see if this solves the issue 395 395 * If not, restart the Simplon server (in Astor → haspp11exp03, right click on Simplon/EH.1 and restart) 396 -* ((( 397 -If nothing works, kill the Simplon process and then start the server again:* ((( 398 -(% class="code" %) 399 -((( 400 -ssh haspp11exp03 390 +* If nothing works, kill the Simplon process and then start the server again: 391 +** ssh haspp11exp03 392 +** ps -ef | grep Simplon 393 +** kill -9 simplon_process_id 401 401 ))) 402 -))) 403 -* ((( 404 -(% class="code" %) 405 -((( 406 -ps -ef | grep Simplon 407 -))) 408 -))) 409 -* ((( 410 -(% class="code" %) 411 -((( 412 -kill -9 simplon_process_id 413 -))) 414 -))) 415 -))) 416 -))) 417 417 {{/layout-cell}} 418 418 {{/layout-section}} 419 - 420 -{{layout-section ac:type="single"}} 421 -{{layout-cell}} 422 -\\ 423 -{{/layout-cell}} 424 -{{/layout-section}} 425 425 {{/layout}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -25 47293711 +250178622 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/25 4729371/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/250178622/14. Serial Crystallography: CFEL TapeDrive