Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -221,8 +221,6 @@ 221 221 222 222 {{layout-section ac:type="single"}} 223 223 {{layout-cell}} 224 ----- 225 - 226 226 == {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 227 227 228 228 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -255,28 +255,50 @@ 255 255 \\ 256 256 257 257 * Open beam shutter BS1 in //CrystalControl //or// P11 XRayFeed // 256 +{{/layout-cell}} 258 258 259 -\\ 258 +{{layout-cell}} 259 +[[image:attach:kamzik_safety.PNG||height="400"]] 260 +{{/layout-cell}} 261 +{{/layout-section}} 260 260 261 -//**Set run parameters and go 🏃💥**// 263 +{{layout-section ac:type="single"}} 264 +{{layout-cell}} 265 +---- 262 262 267 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 268 + 269 +---- 270 +{{/layout-cell}} 271 +{{/layout-section}} 272 + 273 +{{layout-section ac:type="two_equal"}} 274 +{{layout-cell}} 275 +**Set run parameters and go 🏃💥** 276 + 263 263 1. Set your desired No. of frames 264 264 1. Match exposure time with chopper setting or set desired exposure time 265 265 1. Check trigger setting and match to chopper setting 266 -no chopper → external triffer //off 267 -// chopper → external trigger// on 280 +1. To start the run, click "<Call>" next to //start_run (exposure ) 268 268 // 269 -1. To start the run, click "<Call>" next to //start_run (exposure )// 270 -{{/layout-cell}} 271 271 272 -{{layout-cell}} 273 -[[image:attach:Kamzik_run(2).PNG]] 283 +\\ 284 + 285 +\\ 286 + 287 +**After data collection/Before entering the exp. hutch:** 288 + 289 +1. Go to "Safety" in kamzik. 290 +1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 291 +11. Drive the collimator out 292 +11. Drive the detector back to 1500 mm 293 +1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 294 + 295 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 274 274 {{/layout-cell}} 275 -{{/layout-section}} 276 276 277 -{{layout-section ac:type="single"}} 278 278 {{layout-cell}} 279 -(% class="relative-table wrapped" style="width:55.9569%;" %)299 +(% class="wrapped relative-table" style="width: 100.0%;" %) 280 280 |=((( 281 281 Parameter 282 282 )))|=((( ... ... @@ -287,7 +287,7 @@ 287 287 |((( 288 288 Images number 289 289 )))|((( 290 -number of frames you want to collect 310 +Set number of frames you want to collect 291 291 )))|(% colspan="1" %)((( 292 292 usually 100k - 200k, but adjust according to hitrate 293 293 ... ... @@ -322,39 +322,16 @@ 322 322 )))|(% colspan="1" %)((( 323 323 \\ 324 324 ))) 325 - 326 ----- 345 +|(% colspan="1" %)((( 346 +move_detector (distance) 347 +)))|(% colspan="1" %)((( 348 +Set detector distance 349 +)))|(% colspan="1" %)((( 350 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 351 +))) 327 327 {{/layout-cell}} 328 328 {{/layout-section}} 329 329 330 -{{layout-section ac:type="two_equal"}} 331 -{{layout-cell}} 332 -**After data collection/Before entering the exp. hutch:** 333 - 334 -1. Go to "Safety" in kamzik. 335 -1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 336 -11. Drive the collimator out 337 -11. Drive the detector back to 1500 mm 338 -1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 339 - 340 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png]] 341 -{{/layout-cell}} 342 - 343 -{{layout-cell}} 344 -\\ 345 - 346 -\\ 347 - 348 -\\ 349 - 350 -\\ 351 - 352 -\\ 353 - 354 -[[image:attach:safety_kamzik.PNG]] 355 -{{/layout-cell}} 356 -{{/layout-section}} 357 - 358 358 {{layout-section ac:type="single"}} 359 359 {{layout-cell}} 360 360 ----
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2547293 781 +254729368 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2547293 78/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/254729368/14. Serial Crystallography: CFEL TapeDrive