Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -221,8 +221,6 @@ 221 221 222 222 {{layout-section ac:type="single"}} 223 223 {{layout-cell}} 224 ----- 225 - 226 226 == {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 227 227 228 228 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -263,20 +263,17 @@ 263 263 1. Set your desired No. of frames 264 264 1. Match exposure time with chopper setting or set desired exposure time 265 265 1. Check trigger setting and match to chopper setting 266 -no chopper → external triffer //off 267 -// chopper → external trigger// on 268 -// 269 269 1. To start the run, click "<Call>" next to //start_run (exposure )// 270 270 {{/layout-cell}} 271 271 272 272 {{layout-cell}} 273 -[[image:attach:Kamzik_run(2).PNG]] 268 +[[image:attach:Kamzik_run(2).PNG||height="400"]] 274 274 {{/layout-cell}} 275 275 {{/layout-section}} 276 276 277 -{{layout-section ac:type=" single"}}272 +{{layout-section ac:type="two_equal"}} 278 278 {{layout-cell}} 279 -(% class="relative-table wrapped"style="width: 55.9569%;" %)274 +(% class="relative-table" %) 280 280 |=((( 281 281 Parameter 282 282 )))|=((( ... ... @@ -287,7 +287,7 @@ 287 287 |((( 288 288 Images number 289 289 )))|((( 290 -number of frames you want to collect 285 +Set number of frames you want to collect 291 291 )))|(% colspan="1" %)((( 292 292 usually 100k - 200k, but adjust according to hitrate 293 293 ... ... @@ -322,12 +322,15 @@ 322 322 )))|(% colspan="1" %)((( 323 323 \\ 324 324 ))) 325 - 326 ----- 320 +|(% colspan="1" %)((( 321 +move_detector (distance) 322 +)))|(% colspan="1" %)((( 323 +Set detector distance 324 +)))|(% colspan="1" %)((( 325 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 326 +))) 327 327 {{/layout-cell}} 328 -{{/layout-section}} 329 329 330 -{{layout-section ac:type="two_equal"}} 331 331 {{layout-cell}} 332 332 **After data collection/Before entering the exp. hutch:** 333 333 ... ... @@ -337,22 +337,8 @@ 337 337 11. Drive the detector back to 1500 mm 338 338 1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 339 339 340 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png]] 338 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 341 341 {{/layout-cell}} 342 - 343 -{{layout-cell}} 344 -\\ 345 - 346 -\\ 347 - 348 -\\ 349 - 350 -\\ 351 - 352 -\\ 353 - 354 -[[image:attach:safety_kamzik.PNG]] 355 -{{/layout-cell}} 356 356 {{/layout-section}} 357 357 358 358 {{layout-section ac:type="single"}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -25472937 81 +254729370 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/25472937 8/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/254729370/14. Serial Crystallography: CFEL TapeDrive