Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -57,7 +57,7 @@ 57 57 58 58 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ==== 59 59 60 -* Click the 'main tape' icon 60 +* Click on the 'main tape' icon 61 61 * Change the velocity by typing anything from **0.3-3.0 mm/s** 62 62 * Common velocity is 1.0-1.5 mm/s 63 63 * kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. ... ... @@ -66,7 +66,7 @@ 66 66 67 67 ==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 68 68 69 -* Click on the 'nozzle' icon.69 +* Click an the 'nozzle' icon. 70 70 * ((( 71 71 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 72 72 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. ... ... @@ -214,15 +214,12 @@ 214 214 * (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 215 215 * (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 216 216 ** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 217 -* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms (technical exposure will always be 7.7 ms, since max. frame rate is 133 Hz 218 -// 217 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 219 219 {{/layout-cell}} 220 220 {{/layout-section}} 221 221 222 222 {{layout-section ac:type="single"}} 223 223 {{layout-cell}} 224 ----- 225 - 226 226 == {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 227 227 228 228 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -245,40 +245,60 @@ 245 245 246 246 (% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 247 247 248 -(% style="color: rgb(0,0,0);" %)Click " Run" icon in kamzik.245 +(% style="color: rgb(0,0,0);" %)Click "Safety" icon in kamzik. 249 249 250 -* Put detector distance 200 in //prepare_for_measurement ( ) 251 -// 252 -* Click "<Call>" next to //prepare_for_measurement 253 -//This will:\\ 254 -** drive the collimator in //IN// position 255 -** drive detector to 200 mm 247 +* Put collimator in 248 +** Click "<Call>" next to //collimator_in// 256 256 257 257 \\ 258 258 259 259 * Open beam shutter BS1 in //CrystalControl //or// P11 XRayFeed // 253 +{{/layout-cell}} 260 260 261 -\\ 255 +{{layout-cell}} 256 +[[image:attach:kamzik_safety.PNG||height="400"]] 257 +{{/layout-cell}} 258 +{{/layout-section}} 262 262 263 -//**Set run parameters and go 🏃💥**// 260 +{{layout-section ac:type="single"}} 261 +{{layout-cell}} 262 +---- 264 264 265 -1. Set your desired No. of frames 266 -1. Match exposure time with chopper setting or set desired exposure time 267 -1. Check trigger setting and match to chopper setting 268 -no chopper → external triffer //off 269 -// chopper → external trigger// on 270 -// 271 -1. To start the run, click "<Call>" next to //start_run (exposure )// 264 +Click "Start/Run" icon in kamzik. 265 + 266 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 267 + 268 +---- 272 272 {{/layout-cell}} 270 +{{/layout-section}} 273 273 272 +{{layout-section ac:type="two_equal"}} 274 274 {{layout-cell}} 275 -[[image:attach:Kamzik_run(2).PNG]] 274 +**Set run parameters and go 🏃💥** 275 + 276 +1. Set your desired No. of frames 277 +1. Match exposure time with chopper setting 278 +1. Check trigger setting and match to chopper setting 279 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 280 +1. To start the run, click "<Call>" next to //exposure time// 281 + 282 +\\ 283 + 284 +\\ 285 + 286 +**After data collection/Before entering the exp. hutch:** 287 + 288 +1. Go to "Safety" in kamzik. 289 +1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 290 +11. Drive the collimator out 291 +11. Drive the detector back to 1500 mm 292 +1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 293 + 294 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 276 276 {{/layout-cell}} 277 -{{/layout-section}} 278 278 279 -{{layout-section ac:type="single"}} 280 280 {{layout-cell}} 281 -(% class="relative-table wrapped" style="width:55.9569%;" %)298 +(% class="wrapped relative-table" style="width: 100.0%;" %) 282 282 |=((( 283 283 Parameter 284 284 )))|=((( ... ... @@ -289,7 +289,7 @@ 289 289 |((( 290 290 Images number 291 291 )))|((( 292 -number of frames you want to collect 309 +Set number of frames you want to collect 293 293 )))|(% colspan="1" %)((( 294 294 usually 100k - 200k, but adjust according to hitrate 295 295 ... ... @@ -302,7 +302,7 @@ 302 302 303 303 \\ 304 304 )))|(% colspan="1" %)((( 305 -chopper at 133 Hz → 7.7 ms(opening time will be 3.7)322 +chopper at 133 Hz → 3.7 ms 306 306 307 307 chopper at 66 Hz → 7.7 ms 308 308 ... ... @@ -324,39 +324,25 @@ 324 324 )))|(% colspan="1" %)((( 325 325 \\ 326 326 ))) 327 - 328 ----- 344 +|(% colspan="1" %)((( 345 +move_detector (distance) 346 +)))|(% colspan="1" %)((( 347 +Set detector distance 348 +)))|(% colspan="1" %)((( 349 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 350 +))) 351 +|(% colspan="1" %)((( 352 +Diode voltage 353 +)))|(% colspan="1" %)((( 354 +read out of diode 355 +)))|(% colspan="1" %)((( 356 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 357 +Call local contact 358 +** 359 +))) 329 329 {{/layout-cell}} 330 330 {{/layout-section}} 331 331 332 -{{layout-section ac:type="two_equal"}} 333 -{{layout-cell}} 334 -**After data collection/Before entering the exp. hutch:** 335 - 336 -1. Go to "Safety" in kamzik. 337 -1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 338 -11. Drive the collimator out 339 -11. Drive the detector back to 1500 mm 340 -1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 341 - 342 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png]] 343 -{{/layout-cell}} 344 - 345 -{{layout-cell}} 346 -\\ 347 - 348 -\\ 349 - 350 -\\ 351 - 352 -\\ 353 - 354 -\\ 355 - 356 -[[image:attach:safety_kamzik.PNG]] 357 -{{/layout-cell}} 358 -{{/layout-section}} 359 - 360 360 {{layout-section ac:type="single"}} 361 361 {{layout-cell}} 362 362 ----
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -28 19807681 +252826005 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/28 1980768/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/252826005/14. Serial Crystallography: CFEL TapeDrive