... ... @@ -221,8 +221,6 @@
221 221  
222 222  {{layout-section ac:type="single"}}
223 223  {{layout-cell}}
224 -----
225 -
226 226  == {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** ==
227 227  
228 228  Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command:
... ... @@ -245,40 +245,60 @@
245 245  
246 246  (% style="color: rgb(255,0,0);" %)//always after entering the hutch!//
247 247  
248 -(% style="color: rgb(0,0,0);" %)Click "Run" icon in kamzik.
246 +(% style="color: rgb(0,0,0);" %)Click "Safety" icon in kamzik.
249 249  
250 -* Put detector distance 200 in //prepare_for_measurement (      )
251 -//
252 -* Click "<Call>" next to //prepare_for_measurement
253 -//This will:\\
254 -** drive the collimator in //IN// position
255 -** drive detector to 200 mm
248 +* Put collimator in
249 +** Click "<Call>" next to //collimator_in//
256 256  
257 257  \\
258 258  
259 259  * Open beam shutter BS1 in //CrystalControl //or// P11 XRayFeed //
254 +{{/layout-cell}}
260 260  
261 -\\
256 +{{layout-cell}}
257 +[[image:attach:kamzik_safety.PNG||height="400"]]
258 +{{/layout-cell}}
259 +{{/layout-section}}
262 262  
263 -//**Set run parameters and go 🏃💥**//
261 +{{layout-section ac:type="single"}}
262 +{{layout-cell}}
263 +----
264 264  
265 -1. Set your desired No. of frames
266 -1. Match exposure time with chopper setting or set desired exposure time
267 -1. Check trigger setting and match to chopper setting
268 -no chopper → external triffer //off
269 -// chopper → external trigger// on
270 -//
271 -1. To start the run, click "<Call>" next to //start_run (exposure    )//
265 +Click "Start/Run" icon in kamzik.
266 +
267 +[[image:attach:kamzik_run-tile.jpg||height="400"]]
268 +
269 +----
272 272  {{/layout-cell}}
271 +{{/layout-section}}
273 273  
273 +{{layout-section ac:type="two_equal"}}
274 274  {{layout-cell}}
275 -[[image:attach:Kamzik_run(2).PNG]]
275 +**Set run parameters and go 🏃💥**
276 +
277 +1. Set your desired No. of frames
278 +1. Match exposure time with chopper setting
279 +1. Check trigger setting and match to chopper setting
280 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it.
281 +1. To start the run, click "<Call>" next to //exposure time//
282 +
283 +\\
284 +
285 +\\
286 +
287 +**After data collection/Before entering the exp. hutch:**
288 +
289 +1. Go to "Safety" in kamzik.
290 +1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically:
291 +11. Drive the collimator out
292 +11. Drive the detector back to 1500 mm
293 +1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left).
294 +
295 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]]
276 276  {{/layout-cell}}
277 -{{/layout-section}}
278 278  
279 -{{layout-section ac:type="single"}}
280 280  {{layout-cell}}
281 -(% class="relative-table wrapped" style="width: 55.9569%;" %)
299 +(% class="wrapped relative-table" style="width: 100.0%;" %)
282 282  |=(((
283 283  Parameter
284 284  )))|=(((
... ... @@ -289,7 +289,7 @@
289 289  |(((
290 290  Images number
291 291  )))|(((
292 -number of frames you want to collect
310 +Set number of frames you want to collect
293 293  )))|(% colspan="1" %)(((
294 294  usually 100k - 200k, but adjust according to hitrate
295 295  
... ... @@ -324,39 +324,16 @@
324 324  )))|(% colspan="1" %)(((
325 325  \\
326 326  )))
327 -
328 -----
345 +|(% colspan="1" %)(((
346 +move_detector (distance)
347 +)))|(% colspan="1" %)(((
348 +Set detector distance
349 +)))|(% colspan="1" %)(((
350 +200.0 mm   (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>"
351 +)))
329 329  {{/layout-cell}}
330 330  {{/layout-section}}
331 331  
332 -{{layout-section ac:type="two_equal"}}
333 -{{layout-cell}}
334 -**After data collection/Before entering the exp. hutch:**
335 -
336 -1. Go to "Safety" in kamzik.
337 -1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically:
338 -11. Drive the collimator out
339 -11. Drive the detector back to 1500 mm
340 -1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left).
341 -
342 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png]]
343 -{{/layout-cell}}
344 -
345 -{{layout-cell}}
346 -\\
347 -
348 -\\
349 -
350 -\\
351 -
352 -\\
353 -
354 -\\
355 -
356 -[[image:attach:safety_kamzik.PNG]]
357 -{{/layout-cell}}
358 -{{/layout-section}}
359 -
360 360  {{layout-section ac:type="single"}}
361 361  {{layout-cell}}
362 362  ----