Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Objects (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -221,8 +221,6 @@ 221 221 222 222 {{layout-section ac:type="single"}} 223 223 {{layout-cell}} 224 ----- 225 - 226 226 == {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 227 227 228 228 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -247,12 +247,10 @@ 247 247 248 248 (% style="color: rgb(0,0,0);" %)Click "Run" icon in kamzik. 249 249 250 -* Put detector distance 200 in //prepare_for_measurement ( ) 248 +* Put collimator in 249 +** Put detector distance 200 in //prepare_for_measurement ( ) 251 251 // 252 -* Click "<Call>" next to //prepare_for_measurement 253 -//This will:\\ 254 -** drive the collimator in //IN// position 255 -** drive detector to 200 mm 251 +** Click "<Call>" next to //prepare_for_measurement// 256 256 257 257 \\ 258 258 ... ... @@ -265,20 +265,17 @@ 265 265 1. Set your desired No. of frames 266 266 1. Match exposure time with chopper setting or set desired exposure time 267 267 1. Check trigger setting and match to chopper setting 268 -no chopper → external triffer //off 269 -// chopper → external trigger// on 270 -// 271 271 1. To start the run, click "<Call>" next to //start_run (exposure )// 272 272 {{/layout-cell}} 273 273 274 274 {{layout-cell}} 275 -[[image:attach:Kamzik_run(2).PNG]] 268 +[[image:attach:Kamzik_run(2).PNG||height="400"]] 276 276 {{/layout-cell}} 277 277 {{/layout-section}} 278 278 279 -{{layout-section ac:type=" single"}}272 +{{layout-section ac:type="two_equal"}} 280 280 {{layout-cell}} 281 -(% class="relative-table wrapped"style="width: 55.9569%;" %)274 +(% class="relative-table" %) 282 282 |=((( 283 283 Parameter 284 284 )))|=((( ... ... @@ -289,7 +289,7 @@ 289 289 |((( 290 290 Images number 291 291 )))|((( 292 -number of frames you want to collect 285 +Set number of frames you want to collect 293 293 )))|(% colspan="1" %)((( 294 294 usually 100k - 200k, but adjust according to hitrate 295 295 ... ... @@ -324,12 +324,15 @@ 324 324 )))|(% colspan="1" %)((( 325 325 \\ 326 326 ))) 327 - 328 ----- 320 +|(% colspan="1" %)((( 321 +move_detector (distance) 322 +)))|(% colspan="1" %)((( 323 +Set detector distance 324 +)))|(% colspan="1" %)((( 325 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 326 +))) 329 329 {{/layout-cell}} 330 -{{/layout-section}} 331 331 332 -{{layout-section ac:type="two_equal"}} 333 333 {{layout-cell}} 334 334 **After data collection/Before entering the exp. hutch:** 335 335 ... ... @@ -339,22 +339,8 @@ 339 339 11. Drive the detector back to 1500 mm 340 340 1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 341 341 342 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png]] 338 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 343 343 {{/layout-cell}} 344 - 345 -{{layout-cell}} 346 -\\ 347 - 348 -\\ 349 - 350 -\\ 351 - 352 -\\ 353 - 354 -\\ 355 - 356 -[[image:attach:safety_kamzik.PNG]] 357 -{{/layout-cell}} 358 358 {{/layout-section}} 359 359 360 360 {{layout-section ac:type="single"}}
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2 819807681 +254729370 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2 81980768/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/254729370/14. Serial Crystallography: CFEL TapeDrive