Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 22 removed)
- 20211201_094101.jpg
- 20211201_094111.jpg
- 20211201_095033.jpg
- 20211201_095205.jpg
- 20211201_095232.jpg
- 20211201_095534.jpg
- 20211212_233140.jpg
- Kamzik_run(2).PNG
- Screenshot from 2022-04-04 19-36-29.png
- TapeDrive coords.PNG
- TapeDrive scheme.png
- TapeDrive_beschriftet-tile.jpg
- TapeDrive_beschriftet.PNG
- kamzik_nozzle.PNG
- kamzik_run-tile.jpg
- kamzik_run.PNG
- kamzik_safety.PNG
- kamzik_tape.PNG
- safety_kamzik.PNG
- screen.PNG
- server client.PNG
- tape reset.PNG
-
Objects (1 modified, 0 added, 1 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - 08. Serial Crystallography: CFEL TapeDrive1 +14. Serial Crystallography: CFEL TapeDrive - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. tabermah1 +XWiki.ahenkel - Content
-
... ... @@ -3,28 +3,32 @@ 3 3 {{layout-cell}} 4 4 [[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]] 5 5 6 +\\ 6 6 7 -{{toc/}} 8 +{{toc minLevel="2"/}} 8 8 10 +\\ 9 9 10 10 ---- 11 11 12 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}} 8.1. Sample characteristics and preparation =14 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** == 13 13 14 - * Suspension of microcrystals, **at least** 200 µL with 20% crystal density (more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.16 +suspension of microcrystals, **at least** 200 µL with 20% crystal density (more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 15 15 16 16 Preparation: 17 17 18 -* filter through 30 µm (green) or 50 µm (yellow)cell filter intoanEppendorf or Falcon (original!) tube20 +* filter through 30 µm cell filter (green) into Eppendorf or Falcon (original!) tube 19 19 20 20 [[image:attach:20211201_095534.jpg||height="250"]] 21 21 24 +\\ 22 22 23 23 ---- 24 24 25 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}8.2. Connecting sample to ElveFlow, sample exchange = 28 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}**14.2 Connecting sample to ElveFlow, sample exchange 29 +** == 26 26 27 -After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish tube goesallthe way to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!**31 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 28 28 29 29 Be aware to which channel and nozzle line your sample is connected. 30 30 ... ... @@ -38,47 +38,46 @@ 38 38 39 39 [[image:attach:20211201_095232.jpg||height="250"]][[image:attach:20211201_095205.jpg||height="250"]] 40 40 45 +\\ 41 41 42 42 ---- 43 43 44 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}8.3. TapeDrive operation = 49 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}**14.3 TapeDrive operation 50 +** == 45 45 46 -The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 47 - 52 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 48 48 Now start the client. Same thing, a terminal will open, shortly after a small window. 49 49 50 50 Click 'Devices' in the **client session** to open the control window. 51 51 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 52 52 53 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}Tape == 58 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ==== 54 54 55 -* Click the 'main tape' icon 60 +* Click on the 'main tape' icon 56 56 * Change the velocity by typing anything from **0.3-3.0 mm/s** 57 57 * Common velocity is 1.0-1.5 mm/s 58 58 * kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 59 - 64 +\\ 65 +* [[image:attach:kamzik_tape.PNG||height="400"]] 60 60 61 - [[image:attach:kamzik_tape.PNG||height="400"]]67 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 62 62 63 - 64 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}Sample nozzle == 65 - 66 -* Click on the 'nozzle' icon. 69 +* Click an the 'nozzle' icon. 67 67 * ((( 68 68 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. 69 69 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 70 70 71 71 72 -(% style="color: #ff0000" %)**!!! **(% style="color:#000000" %)**During data collection make sure in which direction you are movingthe nozzle, do not move nozzle into beam**(% style="color:#ff0000" %)**!!!**(%%)75 +(% style="color: rgb(255,0,0);" %)**!!! **(% style="color: rgb(255, 0, 0); color: rgb(0, 0, 0)" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color: rgb(255,0,0);" %)** !!!**(%%) 73 73 \\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 74 74 75 75 (% class="wrapped" %) 76 76 |=((( 77 - 80 +\\ 78 78 )))|=((( 79 79 direction 80 80 )))|=((( 81 -recommended step size 84 +recommended step size 82 82 for visual adjustment 83 83 )))|=(% colspan="1" %)((( 84 84 recommended step size ... ... @@ -113,33 +113,38 @@ 113 113 be careful with -z, tape could be pushed out of focus 114 114 ))) 115 115 116 - 119 +** 120 +\\** 117 117 ))) 122 +* [[image:attach:kamzik_nozzle.PNG||height="400"]] 118 118 119 - [[image:attach:kamzik_nozzle.PNG||height="400"]]124 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 120 120 121 -== == 122 - 123 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}Temperature control/Chiller == 124 - 125 125 * The chiller circulates fluid through the gas nozzle. 126 126 127 - == {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}Gas nozzle ==128 +\\ 128 128 130 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 129 129 130 - == {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}IR camera ==132 +\\ 131 131 134 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 132 132 136 +\\ 137 + 133 133 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 134 134 135 135 xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 136 - password: //written on control laptop (changes every 6 months)// 141 + password: //written on control laptop (changes every 6 months) 142 +// 137 137 144 +\\ 138 138 146 +\\ 139 139 140 140 ---- 141 141 142 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}} 8.4. Tape roll exchange =150 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}}**14.4 Tape roll exchange** == 143 143 144 144 The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 145 145 ... ... @@ -148,7 +148,7 @@ 148 148 * Get a new tape roll (bottom left on the cart). **Polypropylen 15 µm** 149 149 * Cut the first cm of the new tape roll, directly behind the black sticky part. 150 150 * Place new roll on roll holder and use sticky tape to attach the end of the old tape to the beginning of the new roll. 151 -* Open magnetic tape stabilizer on the **left side**. (% style="color: #ff0000" %)//!!!BEAMSTOP!!!//159 +* Open magnetic tape stabilizer on the **left side**. (% style="color: rgb(255,0,0);" %)//!!!BEAMSTOP!!!// 152 152 * Start the tape (3mm/s). Once the connetion side has arrived at the collector roll, stop the tape (0mm/s). 153 153 * Again, cut the tape directly behind the connection side. Replace the the old roll with the **empty **one. Old roll can be discarded. 154 154 * Attach new tape to the empty roll by using some sticky tape. ... ... @@ -155,11 +155,15 @@ 155 155 * Close tape stabilizer. 156 156 * Reset tape counter in kamzik by clicking "<Call>" in "Main-Tape". 157 157 158 -**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]]** 166 +**[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]] 167 +** 159 159 169 +\\ 160 160 171 +\\ 161 161 162 - 173 +** 174 +** 163 163 {{/layout-cell}} 164 164 {{/layout-section}} 165 165 ... ... @@ -167,19 +167,19 @@ 167 167 {{layout-cell}} 168 168 ---- 169 169 170 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}} 8.5.Chopper =182 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}}**14.5 Chopper** == 171 171 172 172 start chopper gui from terminal: 173 173 174 174 (% class="code" %) 175 175 ((( 176 - cd /gpfs/local/shared/ChopperControl 188 + cd /gpfs/local/shared/ChopperControl 177 177 ))) 178 178 179 179 (% class="code" %) 180 180 ((( 181 181 python chopperControl.py 182 -\\ 194 +\\\\ 183 183 ))) 184 184 {{/layout-cell}} 185 185 {{/layout-section}} ... ... @@ -192,75 +192,94 @@ 192 192 {{layout-cell}} 193 193 **Chopper → no Chopper** 194 194 195 -* decrease frequency by max. 10 Hz steps 207 +* decrease frequency by max. 10 Hz steps\\ 196 196 ** click arrow down 10x, "Set", arrow down 10x, "Set", .... 197 197 * at frequency = 10 Hz, click "Stop" 198 -* set "Hole" to <none> (% style="color: #ff0000" %)//Takes some minutes//210 +* set "Hole" to <none> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 199 199 200 -(% style="color: #000000" %)**no Chopper → Chopper**212 +(% style="color: rgb(0,0,0);" %)**no Chopper → Chopper** 201 201 202 -* (% style="color: #000000" %)set "Hole" to <Inner hole (largest)> (% style="color:#ff0000" %)//Takes some minutes//203 -* (% style="color: #000000" %)increase frequency by max. 10 Hz steps204 -** (% style="color: #000000" %)click arrow up 10x, "Set", arrow up 10x, "Set", .....205 -* (% style="color: #000000" %)//usually 130Hz, results in exposure time of 3.7 ms(technical exposure will always be 7.7 ms, since max. frame rate is 130 Hz//214 +* (% style="color: rgb(0,0,0);" %)set "Hole" to <Inner hole (largest)> (% style="color: rgb(255,0,0);" %)//Takes some minutes// 215 +* (% style="color: rgb(0,0,0);" %)increase frequency by max. 10 Hz steps 216 +** (% style="color: rgb(0,0,0);" %)click arrow up 10x, "Set", arrow up 10x, "Set", ..... 217 +* (% style="color: rgb(0,0,0);" %)//usually 133 Hz, results in exposure time of 3.7 ms// 206 206 {{/layout-cell}} 207 207 {{/layout-section}} 208 208 209 -{{layout-section ac:type=" single"}}221 +{{layout-section ac:type="two_equal"}} 210 210 {{layout-cell}} 211 -- ---223 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 212 212 213 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}8.6. Data collection = 214 - 215 215 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 216 216 217 217 (% class="code" %) 218 218 ((( 219 - xfreerdp +clipboard /size:1920x1080 /u: cfelusr /v:cfeld-tapetop229 + xfreerdp +clipboard /size:1920x1080 /u:Cfelusr /v:cfeld-pcx22611 220 220 password: written on control laptop (changes every 6 months) 221 221 ))) 222 222 223 223 //>>usually the terminal is open, just repeat previous command with arrow up, enter and type in the password// 224 224 225 - 226 -{{/layout-cell}} 227 -{{/layout-section}} 235 +\\ 228 228 229 -{{layout-section ac:type="two_left_sidebar"}} 230 -{{layout-cell}} 231 231 **Check list:** 232 232 233 -(% style="color: #ff0000" %)//always after entering the hutch!//239 +(% style="color: rgb(255,0,0);" %)//always after entering the hutch!// 234 234 235 -(% style="color: #000000" %)Click "Run" icon in kamzik.241 +(% style="color: rgb(0,0,0);" %)Click "Safety" icon in kamzik. 236 236 237 -* Put detector distance 200 in //prepare_for_measurement ( )// 238 -* Click "<Call>" next to //prepare_for_measurement// 239 -This will: 240 -** drive the collimator in //IN// position 241 -** drive detector to 200 mm 243 +* Put collimator in 244 +** Click "<Call>" next to //collimator_in// 242 242 243 - * Open beam shutter BS1 in //CrystalControl //or// P11 XRayFeed //246 +\\ 244 244 245 -//**Set run parameters and go 🏃💥**// 246 - 247 -1. Set your desired No. of frames 248 -1. Enter the protein ID of your crystal sample 249 -1. Match exposure time with chopper setting or set desired exposure time 250 -1. Check trigger setting and match to chopper setting 251 -no chopper → external triffer //off// 252 - chopper → external trigger// on// 253 -1. To start the run, click "<Call>" next to //start_run (exposure )// 248 +* Open beam shutter BS1 in //CrystalControl// 254 254 {{/layout-cell}} 255 255 256 256 {{layout-cell}} 257 -[[image:attach: Kamzik_run(2).PNG]]252 +[[image:attach:kamzik_safety.PNG||height="250"]] 258 258 {{/layout-cell}} 259 259 {{/layout-section}} 260 260 261 261 {{layout-section ac:type="single"}} 262 262 {{layout-cell}} 263 -(% class="relative-table wrapped" style="width:55.9569%" %) 258 +---- 259 + 260 +Click "Start/Run" icon in kamzik. 261 + 262 +[[image:attach:kamzik_run-tile.jpg||height="400"]] 263 + 264 +---- 265 +{{/layout-cell}} 266 +{{/layout-section}} 267 + 268 +{{layout-section ac:type="two_equal"}} 269 +{{layout-cell}} 270 +**Set run parameters and go 🏃💥** 271 + 272 +1. Set your desired No. of frames 273 +1. Match exposure time with chopper setting 274 +1. Check trigger setting and match to chopper setting 275 +1. Set detector distance to 200.0 mm, confirm with //enter// and click "<Call>" button next to it. 276 +1. To start the run, click "<Call>" next to //exposure time// 277 + 278 +\\ 279 + 280 +\\ 281 + 282 +**After data collection/Before entering the exp. hutch:** 283 + 284 +1. Go to "Safety" in kamzik. 285 +1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 286 +11. Drive the collimator out 287 +11. Drive the detector back to 1500 mm 288 +1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 289 + 290 +[[image:attach:Screenshot from 2022-04-04 19-36-29.png||height="400"]] 291 +{{/layout-cell}} 292 + 293 +{{layout-cell}} 294 +(% class="wrapped relative-table" style="width: 100.0%;" %) 264 264 |=((( 265 265 Parameter 266 266 )))|=((( ... ... @@ -271,7 +271,7 @@ 271 271 |((( 272 272 Images number 273 273 )))|((( 274 -number of frames you want to collect 305 +Set number of frames you want to collect 275 275 )))|(% colspan="1" %)((( 276 276 usually 100k - 200k, but adjust according to hitrate 277 277 ... ... @@ -282,9 +282,12 @@ 282 282 )))|((( 283 283 exposure time of Eiger 284 284 285 - 316 +\\ 286 286 )))|(% colspan="1" %)((( 287 -with chopper → opening time displayed in chopper GUI 318 +chopper at 133 Hz → 3.7 ms 319 + 320 +chopper at 66 Hz → 7.7 ms 321 + 288 288 no chopper → 7.7 ms 289 289 290 290 ---- ... ... @@ -294,7 +294,7 @@ 294 294 )))|((( 295 295 changes automatically 296 296 )))|(% colspan="1" %)((( 297 - 331 +\\ 298 298 ))) 299 299 |(% colspan="1" %)((( 300 300 Detector distance ... ... @@ -301,59 +301,44 @@ 301 301 )))|(% colspan="1" %)((( 302 302 current detector postion readout 303 303 )))|(% colspan="1" %)((( 304 - 338 +\\ 305 305 ))) 306 306 |(% colspan="1" %)((( 307 - proteinID341 +move_detector (distance) 308 308 )))|(% colspan="1" %)((( 309 - proteinID ofcrystal sample(see AMARCORD)343 +Set detector distance 310 310 )))|(% colspan="1" %)((( 311 - 345 +200.0 mm (% style="color: rgb(255,0,0);" %)confirm with //enter//, click "<Call>" 312 312 ))) 313 - 314 ----- 347 +|(% colspan="1" %)((( 348 +Diode voltage 349 +)))|(% colspan="1" %)((( 350 +read out of diode 351 +)))|(% colspan="1" %)((( 352 +**~~ 0 !!! higher values indicate missaligned beam stop!!! 353 +Call local contact 354 +** 355 +))) 315 315 {{/layout-cell}} 316 316 {{/layout-section}} 317 317 318 -{{layout-section ac:type="two_equal"}} 319 -{{layout-cell}} 320 -**After data collection/Before entering the exp. hutch:** 321 - 322 -1. Go to "Safety" in kamzik. 323 -1. Click "<Call>" next to //prepare_to_open_hutch. //This will automatically: 324 -11. Drive the collimator out 325 -11. Drive the detector back to 1500 mm 326 -1. Close beam shutter BS1 and break door interlock in //P11 XRayFeed //(monitor top left). 327 - 328 -[[image:attach:Screenshot from 2022-04-04 19-36-29.png]] 329 -{{/layout-cell}} 330 - 331 -{{layout-cell}} 332 - 333 - 334 - 335 - 336 - 337 - 338 -[[image:attach:safety_kamzik.PNG]] 339 -{{/layout-cell}} 340 -{{/layout-section}} 341 - 342 342 {{layout-section ac:type="single"}} 343 343 {{layout-cell}} 344 344 ---- 345 345 346 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Troubleshooting"/}} 8.7.Troubleshooting =363 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Troubleshooting"/}}**14.7 Troubleshooting** == 347 347 348 348 * ((( 349 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped == 366 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 350 350 351 351 * Tape roll empty? 352 352 * motor connected (icon green)? 353 353 ))) 354 354 372 +\\ 373 + 355 355 * ((( 356 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding == 375 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 357 357 358 358 * displayed in green=connected? 359 359 * nozzle holder colliding somewhere? ... ... @@ -360,8 +360,10 @@ 360 360 * motor limits reached? → position displayed in red 361 361 ))) 362 362 382 +\\ 383 + 363 363 * ((( 364 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure == 385 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 365 365 366 366 * channel turned on? 367 367 * Sample empty? ... ... @@ -368,21 +368,20 @@ 368 368 * Nozzle or lines clogged? → flush with water, change nozzle 369 369 ))) 370 370 392 +\\ 393 + 371 371 * ((( 372 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Simplonfilewriter/eigerstreamissues"/}}Simplon filewriter/eiger stream issues == 395 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Simplonfilewriter/eigerstreamissues"/}}Simplon filewriter/eiger stream issues ==== 373 373 374 374 * First, restart kamzik (server+client) and see if this solves the issue 375 375 * If not, restart the Simplon server (in Astor → haspp11exp03, right click on Simplon/EH.1 and restart) 376 376 * ((( 377 -If nothing works, kill the Simplon process and then start the server again:* 378 - 379 -((( 400 +If nothing works, kill the Simplon process and then start the server again:* ((( 380 380 (% class="code" %) 381 381 ((( 382 382 ssh haspp11exp03 383 383 ))) 384 384 ))) 385 - 386 386 * ((( 387 387 (% class="code" %) 388 388 ((( ... ... @@ -396,7 +396,6 @@ 396 396 ))) 397 397 ))) 398 398 ))) 399 -* After the Simplon server is back up, close all kamzik windows and restart (first server, then client) 400 400 ))) 401 401 {{/layout-cell}} 402 402 {{/layout-section}} ... ... @@ -403,7 +403,7 @@ 403 403 404 404 {{layout-section ac:type="single"}} 405 405 {{layout-cell}} 406 - 425 +\\ 407 407 {{/layout-cell}} 408 408 {{/layout-section}} 409 409 {{/layout}}
- 20211201_094101.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -5.8 MB - Content
- 20211201_094111.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -5.6 MB - Content
- 20211201_095033.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -3.1 MB - Content
- 20211201_095205.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -2.8 MB - Content
- 20211201_095232.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -7.2 MB - Content
- 20211201_095534.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -4.4 MB - Content
- 20211212_233140.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -6.5 MB - Content
- Kamzik_run(2).PNG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -134.4 KB - Content
- Screenshot from 2022-04-04 19-36-29.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -133.0 KB - Content
- TapeDrive coords.PNG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.1 KB - Content
- TapeDrive scheme.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -114.3 KB - Content
- TapeDrive_beschriftet-tile.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -539.9 KB - Content
- TapeDrive_beschriftet.PNG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -337.8 KB - Content
- kamzik_nozzle.PNG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -120.5 KB - Content
- kamzik_run-tile.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -466.4 KB - Content
- kamzik_run.PNG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -128.9 KB - Content
- kamzik_safety.PNG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -139.1 KB - Content
- kamzik_tape.PNG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -122.6 KB - Content
- safety_kamzik.PNG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -126.9 KB - Content
- screen.PNG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -94.0 KB - Content
- server client.PNG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -262.2 KB - Content
- tape reset.PNG
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel - Size
-
... ... @@ -1,1 +1,0 @@ 1 -122.3 KB - Content
- Confluence.Code.ConfluencePageClass[0]
-
- Id
-
... ... @@ -1,1 +1,1 @@ 1 -2 350318051 +250178651 - URL
-
... ... @@ -1,1 +1,1 @@ 1 -https://confluence.desy.de/spaces/11/pages/2 35031805/14. Serial Crystallography: CFEL TapeDrive1 +https://confluence.desy.de/spaces/11/pages/250178651/14. Serial Crystallography: CFEL TapeDrive
- XWiki.XWikiRights[0]
-
- Allow/Deny
-
... ... @@ -1,1 +1,0 @@ 1 -Allow - Levels
-
... ... @@ -1,1 +1,0 @@ 1 -view,comment,edit - Users
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel