Changes for page CFEL TapeDrive: Serial Crystallography
Last modified by chatzies on 2025-11-27 11:35
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Objects (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Serial Crystallography: CFEL TapeDrive 1 +08. Serial Crystallography: CFEL TapeDrive - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. chatzies1 +XWiki.tabermah - Content
-
... ... @@ -4,18 +4,18 @@ 4 4 [[image:attach:TapeDrive_beschriftet-tile.jpg||height="400"]] 5 5 6 6 7 -{{toc/}} 7 +{{toc minLevel="2"/}} 8 8 9 9 10 10 ---- 11 11 12 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}} 8.1. Sample characteristics and preparation =12 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}**14.1 Sample characteristics and preparation** == 13 13 14 - * Suspension of microcrystals, **at least** 200 µL with 20% crystal density (more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.14 +suspension of microcrystals, **at least** 200 µL with 20% crystal density (more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc. 15 15 16 16 Preparation: 17 17 18 -* filter through 30 µm (green) or 50 µm (yellow) cellfilterintoanEppendorf or Falcon (original!) tube18 +* filter through 30 µm cell filter (green) or 50 µm (yellow) into Eppendorf or Falcon (original!) tube 19 19 20 20 [[image:attach:20211201_095534.jpg||height="250"]] 21 21 ... ... @@ -22,10 +22,13 @@ 22 22 23 23 ---- 24 24 25 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}} 8.2.Connecting sample to ElveFlow, sample exchange =25 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}**14.2 Connecting sample to ElveFlow, sample exchange** == 26 26 27 -After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish tube goes all the way to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 27 +* 28 +** == 28 28 30 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!** 31 + 29 29 Be aware to which channel and nozzle line your sample is connected. 30 30 31 31 Red → Channel 1, crystal line (nozzle capillary without marks/with red marks) ... ... @@ -41,27 +41,28 @@ 41 41 42 42 ---- 43 43 44 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}} 8.3.TapeDrive operation =47 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.3TapeDriveoperation"/}}**14.3 TapeDrive operation** == 45 45 46 -The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 49 +* 50 +** == 47 47 52 +The TapeDrive is controlled through kamzik. To open kamzik, start the server. A terminal will open and shortly after a small window. 48 48 Now start the client. Same thing, a terminal will open, shortly after a small window. 49 49 50 50 Click 'Devices' in the **client session** to open the control window. 51 51 [[image:attach:screen.PNG||height="250"]][[image:attach:server client.PNG||height="250"]] 52 52 53 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}Tape == 58 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tape"/}}**Tape** ==== 54 54 55 55 * Click the 'main tape' icon 56 56 * Change the velocity by typing anything from **0.3-3.0 mm/s** 57 57 * Common velocity is 1.0-1.5 mm/s 58 58 * kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point. 64 + 65 +* [[image:attach:kamzik_tape.PNG||height="400"]] 59 59 60 - [[image:attach:kamzik_tape.PNG||height="400"]]67 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}**Sample nozzle** ==== 61 61 62 - 63 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}Sample nozzle == 64 - 65 65 * Click on the 'nozzle' icon. 66 66 * ((( 67 67 The nozzle position can be adjusted in xyz by clicking on the arrows up and down. (Double arrow = 10 steps). Step size can be varied, 1mm steps are rather big and should be used carefully. ... ... @@ -68,7 +68,7 @@ 68 68 The absolute position is **not calibrated** and therefore changes after each restart of kamzik. 69 69 70 70 71 -(% style="color:#ff0000" %)**!!! **(% style="color:#000000" %)**During data collection make sure in which direction you are moving the nozzle, do not move nozzle into beam**(% style="color:#ff0000" %)** !!!**(%%)75 +(% style="color:#ff0000" %)**!!! **(% style="color:#000000" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color:#ff0000" %)** !!!**(%%) 72 72 \\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments. 73 73 74 74 (% class="wrapped" %) ... ... @@ -114,18 +114,16 @@ 114 114 115 115 116 116 ))) 121 +* [[image:attach:kamzik_nozzle.PNG||height="400"]] 117 117 118 - [[image:attach:kamzik_nozzle.PNG||height="400"]]123 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}**Temperature control/Chiller** ==== 119 119 120 - 121 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}Temperature control/Chiller == 122 - 123 123 * The chiller circulates fluid through the gas nozzle. 124 124 125 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}Gas nozzle == 127 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Gasnozzle"/}}**Gas nozzle** ==== 126 126 127 127 128 -== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}IR camera == 130 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-IRcamera"/}}**IR camera** ==== 129 129 130 130 131 131 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: ... ... @@ -137,7 +137,7 @@ 137 137 138 138 ---- 139 139 140 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}} 8.4. Tape roll exchange =142 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.4Taperollexchange"/}}**14.4 Tape roll exchange** == 141 141 142 142 The tape stops automatically at 98% used length, if you need to change the rolls for orther reasons, stop the tape (velocity = 0.0 mm/s). 143 143 ... ... @@ -155,6 +155,8 @@ 155 155 156 156 **[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]]** 157 157 160 + 161 + 158 158 159 159 {{/layout-cell}} 160 160 {{/layout-section}} ... ... @@ -163,7 +163,7 @@ 163 163 {{layout-cell}} 164 164 ---- 165 165 166 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}} 8.5.Chopper =170 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.5Chopper"/}}**14.5 Chopper** == 167 167 168 168 start chopper gui from terminal: 169 169 ... ... @@ -175,6 +175,7 @@ 175 175 (% class="code" %) 176 176 ((( 177 177 python chopperControl.py 182 +\\ 178 178 ))) 179 179 {{/layout-cell}} 180 180 {{/layout-section}} ... ... @@ -205,7 +205,7 @@ 205 205 {{layout-cell}} 206 206 ---- 207 207 208 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}} 8.6.Data collection =213 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.6Datacollection"/}}**14.6 Data collection** == 209 209 210 210 Once the hutch is interlocked, set remote control to the TapeDrive laptop by opening a terminal and executing the following command: 211 211 ... ... @@ -229,7 +229,7 @@ 229 229 230 230 (% style="color:#000000" %)Click "Run" icon in kamzik. 231 231 232 -* Put detector distance 200 mmin //prepare_for_measurement ( )//237 +* Put detector distance 200 in //prepare_for_measurement ( )// 233 233 * Click "<Call>" next to //prepare_for_measurement// 234 234 This will: 235 235 ** drive the collimator in //IN// position ... ... @@ -326,6 +326,10 @@ 326 326 {{layout-cell}} 327 327 328 328 334 + 335 + 336 + 337 + 329 329 [[image:attach:safety_kamzik.PNG]] 330 330 {{/layout-cell}} 331 331 {{/layout-section}} ... ... @@ -334,10 +334,10 @@ 334 334 {{layout-cell}} 335 335 ---- 336 336 337 -= {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Troubleshooting"/}} 8.7.Troubleshooting =346 +== {{id name="14.SerialCrystallography:CFELTapeDrive-14.7Troubleshooting"/}}**14.7 Troubleshooting** == 338 338 339 339 * ((( 340 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped == 349 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Tapestopped"/}}Tape stopped ==== 341 341 342 342 * Tape roll empty? 343 343 * motor connected (icon green)? ... ... @@ -344,7 +344,7 @@ 344 344 ))) 345 345 346 346 * ((( 347 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding == 356 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Nozzlemotorsarenotresponding"/}}Nozzle motors are not responding ==== 348 348 349 349 * displayed in green=connected? 350 350 * nozzle holder colliding somewhere? ... ... @@ -352,7 +352,7 @@ 352 352 ))) 353 353 354 354 * ((( 355 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure == 364 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Sampleflowisnotrespondingtohigherpressure"/}}Sample flow is not responding to higher pressure ==== 356 356 357 357 * channel turned on? 358 358 * Sample empty? ... ... @@ -360,7 +360,7 @@ 360 360 ))) 361 361 362 362 * ((( 363 -== {{id name="14.SerialCrystallography:CFELTapeDrive-Simplonfilewriter/eigerstreamissues"/}}Simplon filewriter/eiger stream issues == 372 +==== {{id name="14.SerialCrystallography:CFELTapeDrive-Simplonfilewriter/eigerstreamissues"/}}Simplon filewriter/eiger stream issues ==== 364 364 365 365 * First, restart kamzik (server+client) and see if this solves the issue 366 366 * If not, restart the Simplon server (in Astor → haspp11exp03, right click on Simplon/EH.1 and restart) ... ... @@ -391,4 +391,10 @@ 391 391 ))) 392 392 {{/layout-cell}} 393 393 {{/layout-section}} 403 + 404 +{{layout-section ac:type="single"}} 405 +{{layout-cell}} 406 + 407 +{{/layout-cell}} 408 +{{/layout-section}} 394 394 {{/layout}}
- XWiki.XWikiRights[0]
-
- Allow/Deny
-
... ... @@ -1,1 +1,0 @@ 1 -Allow - Levels
-
... ... @@ -1,1 +1,0 @@ 1 -view,comment,edit - Users
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ahenkel
- XWiki.XWikiRights[1]
-
- Allow/Deny
-
... ... @@ -1,1 +1,0 @@ 1 -Allow - Levels
-
... ... @@ -1,1 +1,0 @@ 1 -view,comment,edit,delete - Users
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.chatzies
- XWiki.XWikiRights[2]
-
- Allow/Deny
-
... ... @@ -1,1 +1,0 @@ 1 -Allow - Levels
-
... ... @@ -1,1 +1,0 @@ 1 -view - Users
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.XWikiGuest