12 12  = {{id name="14.SerialCrystallography:CFELTapeDrive-14.1Samplecharacteristicsandpreparation"/}}8.1. Sample characteristics and preparation =
13 13  
14 -* Suspension of microcrystals, **at least** 200 µL with 20% crystal density (more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.
14 +suspension of microcrystals, **at least** 200 µL with 20% crystal density (more is always better), size range: 2-30 µm, **tip:** bring some mother liquor for washing, filtering, diluting etc.
15 15  
16 16  Preparation:
17 17  
18 -* filter through 30 µm (green) or 50 µm (yellow) cell filter into an Eppendorf or Falcon (original!) tube
18 +* filter through 30 µm cell filter (green) or 50 µm (yellow) into Eppendorf or Falcon (original!) tube
19 19  
20 20  [[image:attach:20211201_095534.jpg||height="250"]]
21 21  
... ... @@ -24,7 +24,7 @@
24 24  
25 25  = {{id name="14.SerialCrystallography:CFELTapeDrive-14.2ConnectingsampletoElveFlow,sampleexchange"/}}8.2. Connecting sample to ElveFlow, sample exchange =
26 26  
27 -After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish tube goes all the way to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!**
27 +After filtration, screw the ElveFlow connector to your Eppendorf or Falcon tube. Make sure that the yellow-ish line goes to the bottom of your tube. You can adjust the length by unscrewing the blue fitting on top and pushing/pulling the yellow-ish line. **Don't forget to tigthen the blue fitting afterwards!**
28 28  
29 29  Be aware to which channel and nozzle line your sample is connected.
30 30  
... ... @@ -56,10 +56,9 @@
56 56  * Change the velocity by typing anything from **0.3-3.0 mm/s**
57 57  * Common velocity is 1.0-1.5 mm/s
58 58  * kamzik displays the used tape in m and %. At 98% the tape will automatically stop since the rolls need to be exchanged at this point.
59 +
60 +* [[image:attach:kamzik_tape.PNG||height="400"]]
59 59  
60 -[[image:attach:kamzik_tape.PNG||height="400"]]
61 -
62 -
63 63  == {{id name="14.SerialCrystallography:CFELTapeDrive-Samplenozzle"/}}Sample nozzle ==
64 64  
65 65  * Click on the 'nozzle' icon.
... ... @@ -68,7 +68,7 @@
68 68  The absolute position is **not calibrated** and therefore changes after each restart of kamzik.
69 69  
70 70  
71 -(% style="color:#ff0000" %)**!!! **(% style="color:#000000" %)**During data collection make sure in which direction you are moving the nozzle, do not move nozzle into beam**(% style="color:#ff0000" %)** !!!**(%%)
70 +(% style="color:#ff0000" %)**!!! **(% style="color:#000000" %)**During data collection make sure in which direction you are moving, do not move nozzle into beam**(% style="color:#ff0000" %)** !!!**(%%)
72 72  \\Adjust the nozzle position by eye until it nearly touches the tape and roughly meets the X-ray interaction point. Then, move to the control hutch to use the on-axis microscope for fine adjustment. Move the nozzle tip to the beam position (red X) and write down the absolut nozzle position. From there move the nozzle in +x to your desired distance.Different distances combined with the tape speed result in several delay times for time-resolved experiments.
73 73  
74 74  (% class="wrapped" %)
... ... @@ -114,10 +114,8 @@
114 114  
115 115  
116 116  )))
116 +* [[image:attach:kamzik_nozzle.PNG||height="400"]]
117 117  
118 -[[image:attach:kamzik_nozzle.PNG||height="400"]]
119 -
120 -
121 121  == {{id name="14.SerialCrystallography:CFELTapeDrive-Temperaturecontrol/Chiller"/}}Temperature control/Chiller ==
122 122  
123 123  * The chiller circulates fluid through the gas nozzle.
... ... @@ -155,6 +155,8 @@
155 155  
156 156  **[[image:attach:20211201_094101.jpg||height="250"]][[image:attach:20211201_094111.jpg||height="250"]][[image:attach:tape reset.PNG||height="250"]]**
157 157  
155 +
156 +
158 158  
159 159  {{/layout-cell}}
160 160  {{/layout-section}}
... ... @@ -175,6 +175,7 @@
175 175  (% class="code" %)
176 176  (((
177 177   python chopperControl.py
177 +\\
178 178  )))
179 179  {{/layout-cell}}
180 180  {{/layout-section}}
... ... @@ -229,7 +229,7 @@
229 229  
230 230  (% style="color:#000000" %)Click "Run" icon in kamzik.
231 231  
232 -* Put detector distance 200 mm in //prepare_for_measurement (      )//
232 +* Put detector distance 200 in //prepare_for_measurement (      )//
233 233  * Click "<Call>" next to //prepare_for_measurement//
234 234  This will:
235 235  ** drive the collimator in //IN// position
... ... @@ -326,6 +326,10 @@
326 326  {{layout-cell}}
327 327  
328 328  
329 +
330 +
331 +
332 +
329 329  [[image:attach:safety_kamzik.PNG]]
330 330  {{/layout-cell}}
331 331  {{/layout-section}}
... ... @@ -391,4 +391,10 @@
391 391  )))
392 392  {{/layout-cell}}
393 393  {{/layout-section}}
398 +
399 +{{layout-section ac:type="single"}}
400 +{{layout-cell}}
401 +
402 +{{/layout-cell}}
403 +{{/layout-section}}
394 394  {{/layout}}
XWiki.XWikiRights[1]
Allow/Deny
... ... @@ -1,1 +1,0 @@
1 -Allow
Levels
... ... @@ -1,1 +1,0 @@
1 -view,comment,edit,delete
Users
... ... @@ -1,1 +1,0 @@
1 -XWiki.chatzies
XWiki.XWikiRights[2]
Allow/Deny
... ... @@ -1,1 +1,0 @@
1 -Allow
Levels
... ... @@ -1,1 +1,0 @@
1 -view
Users
... ... @@ -1,1 +1,0 @@
1 -XWiki.XWikiGuest