Changes for page MTCA ADCs
Last modified by sndueste on 2024/07/08 09:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -57,7 +57,7 @@ 57 57 |((( 58 58 Sampling rate 59 59 )))|((( 60 -2 *60 +2 61 61 )))|((( 62 62 GSPS 63 63 ))) ... ... @@ -75,7 +75,7 @@ 75 75 |((( 76 76 Sampling rate 77 77 )))|((( 78 -4 *78 +4 79 79 )))|((( 80 80 GSPS 81 81 ))) ... ... @@ -87,8 +87,6 @@ 87 87 GHz 88 88 ))) 89 89 90 - ~* note that the sample rate is NOT locked to the FLASH repetition rate ! Thus there is a not integer number of samples between FLASH pulses. The sample rate also differs slightly from ADC card to ADC card. The rough spacing is **1993.846** samples between 2 pulses at 1 MHz for details ask the local contact. 91 - 92 92 \\ 93 93 94 94 ===== ADC and DOOCS / DAQ ===== ... ... @@ -152,28 +152,12 @@ 152 152 153 153 == Pulse energy server: Using the Struck SIS8300-L2D to detect only integrated values of pulses == 154 154 155 -FS-LA (Falko Peters) programmed a pulse detection server that automatically detects peaks in the sign al and integrates the samples around the peak.153 +FS-LA (Falko Peters) programmed a pulse detection server that automatically detects peaks in the signel and integrates the samples around the peak. <\br> things to set: 156 156 157 -Things to set: 158 - 159 -* Min peak height: threshold fro which on some signal is considered to be a peak. The actual peak is then determined as the maximum of the counts after the threshold 155 +* Peak height: from what signal on (incounts) is the signal to be counted as peak 160 160 * pre and post peak integration time: how much ns to be integrated before and after the peak sample that are taken into account for the peak 161 161 * pre and post peak noise time: before and after the samples that are taken for the actual signal these samples are used as background ( they also can be used to define the "deadtime" of the detector before it searches for new peaks. 162 162 163 - \\159 +[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/pulse_energy_server.jpg~|~|alt="pulse_energy_server.jpg" width="400" height="300"~]~]>>attach:pulse_energy_server.jpg]] 164 164 165 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/pulse_energy_server.jpg~|~|alt="pulse_energy_server.jpg" height="400"~]~]>>attach:pulse_energy_server.jpg]] [[image:attach:image2019-11-18_17-9-7.png||height="400"]] 166 - 167 167 \\ 168 - 169 - jddd server panel Definition of the parameters 170 - 171 -\\ 172 - 173 -\\ 174 - 175 -\\ 176 - 177 -\\ 178 - 179 -\\