Changes for page MTCA ADCs

Last modified by sndueste on 2024/07/08 09:50

From version 13.1
edited by sndueste
on 2019/11/19 16:41
Change comment: There is no comment for this version
To version 18.1
edited by sendels
on 2021/02/10 15:08
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.sndueste
1 +XWiki.sendels
Content
... ... @@ -2,7 +2,7 @@
2 2  
3 3  
4 4  
5 -{{toc/}}
5 +{{toc minLevel="2"/}}
6 6  
7 7  ----
8 8  
... ... @@ -101,8 +101,15 @@
101 101  \\{{code language="none"}}/FL1/Experiment/BL3/ADQ412 GHz ADC/CH02/TD{{/code}}
102 102  {{code language="none"}}/FL1/Experiment/BL3/ADQ412 GHz ADC/CH03/TD{{/code}}
103 103  
104 +and at FLASH2
105 +
106 +
107 +\\\\\\\\{{code language="none"}}FL24:/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH00/TD/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH01/TD/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH02/TD/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH03/TD{{/code}}
108 +
109 +\\
110 +
104 104  DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00/CH00.TD  or CH00.DAQ.TD{{/code}}
105 -here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is actvated the {{code language="none"}}CH00.DAQ.TD{{/code}} contins only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is preferable to use ...
112 +here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is activated the {{code language="none"}}CH00.DAQ.TD{{/code}} contains only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is preferable to use ...
106 106  DAQ channel: {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00{{/code}}
107 107  
108 108  in addition there are also additional parameters saved like:
... ... @@ -118,7 +118,8 @@
118 118  * **we can offer [[ Phillips scientific Model 6954>>attach:6954ds.pdf]] amplifiers** to either amplify small signals or to decouple setups which may deliver voltage peaks fro the ADCs.
119 119  * The available ADCs 5x, 10x, 20 x 50x and 100x
120 120  * The ADCs can be borrowed from Markus Braune
121 -* The Amplifiers fot perfectly to the dynamic range of the GHz ADCs - here a  [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]]
128 +* The Amplifiers fit perfectly to the dynamic range of the GHz ADCs - here a  [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]]
129 +* There are also [[BiasTs>>attach:ZX85-12G-S+.pdf]] available ([[link to internal page>>doc:FLASH.Bias T]])
122 122  
123 123  \\
124 124  
... ... @@ -137,7 +137,7 @@
137 137  
138 138  Here is a trace of the first signal, a 1 MHz trigger connected from the x2timer board in the same MTCA:
139 139  
140 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/adc_mhz.jpg~|~|alt="adc_mhz.jpg" width="550" height="500"~]~]>>attach:adc_mhz.jpg]]
148 +[[image:attach:adc_mhz.jpg||height="400"]]
141 141  
142 142  \\
143 143  
... ... @@ -153,8 +153,10 @@
153 153  
154 154  \\
155 155  
156 -[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/pulse_energy_server.jpg~|~|alt="pulse_energy_server.jpg" height="400"~]~]>>attach:pulse_energy_server.jpg]] [[image:attach:image2019-11-18_17-9-7.png||height="400"]]
164 + [[image:attach:image2019-11-18_17-9-7.png||height="400"]]
157 157  
166 +[[image:attach:pulse_energy_server.jpg||height="400"]]
167 +
158 158  \\
159 159  
160 160   jddd  server panel  Definition of the parameters