Changes for page MTCA ADCs
Last modified by sndueste on 2024/07/08 09:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.snd ueste1 +XWiki.sendels - Content
-
... ... @@ -109,7 +109,7 @@ 109 109 \\ 110 110 111 111 DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00/CH00.TD or CH00.DAQ.TD{{/code}} 112 -here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is actvated the {{code language="none"}}CH00.DAQ.TD{{/code}} contins only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is preferable to use ... 112 +here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is activated the {{code language="none"}}CH00.DAQ.TD{{/code}} contains only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is preferable to use ... 113 113 DAQ channel: {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00{{/code}} 114 114 115 115 in addition there are also additional parameters saved like: ... ... @@ -125,7 +125,8 @@ 125 125 * **we can offer [[ Phillips scientific Model 6954>>attach:6954ds.pdf]] amplifiers** to either amplify small signals or to decouple setups which may deliver voltage peaks fro the ADCs. 126 126 * The available ADCs 5x, 10x, 20 x 50x and 100x 127 127 * The ADCs can be borrowed from Markus Braune 128 -* The Amplifiers fot perfectly to the dynamic range of the GHz ADCs - here a [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]] 128 +* The Amplifiers fit perfectly to the dynamic range of the GHz ADCs - here a [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]] 129 +* There are also [[BiasTs>>attach:ZX85-12G-S+.pdf]] available ([[link to internal page>>doc:FLASH.Bias T]]) 129 129 130 130 \\ 131 131 ... ... @@ -144,7 +144,7 @@ 144 144 145 145 Here is a trace of the first signal, a 1 MHz trigger connected from the x2timer board in the same MTCA: 146 146 147 -[[ ~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/adc_mhz.jpg~|~|alt="adc_mhz.jpg" width="550" height="500"~]~]>>attach:adc_mhz.jpg]]148 +[[image:attach:adc_mhz.jpg||height="400"]] 148 148 149 149 \\ 150 150 ... ... @@ -162,6 +162,8 @@ 162 162 163 163 [[~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/pulse_energy_server.jpg~|~|alt="pulse_energy_server.jpg" height="400"~]~]>>attach:pulse_energy_server.jpg]] [[image:attach:image2019-11-18_17-9-7.png||height="400"]] 164 164 166 +[[image:attach:pulse_energy_server.jpg||height="400"]] 167 + 165 165 \\ 166 166 167 167 jddd server panel Definition of the parameters