Changes for page MTCA ADCs
Last modified by sndueste on 2024/07/08 09:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,7 +2,7 @@ 2 2 3 3 4 4 5 -{{toc minLevel="2"/}}5 +{{toc/}} 6 6 7 7 ---- 8 8 ... ... @@ -101,15 +101,8 @@ 101 101 \\{{code language="none"}}/FL1/Experiment/BL3/ADQ412 GHz ADC/CH02/TD{{/code}} 102 102 {{code language="none"}}/FL1/Experiment/BL3/ADQ412 GHz ADC/CH03/TD{{/code}} 103 103 104 -and at FLASH2 105 - 106 - 107 -\\\\\\\\{{code language="none"}}FL24:/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH00/TD/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH01/TD/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH02/TD/FL2/Experiment/MTCA-EXP1/ADQ412 GHz ADC/CH03/TD{{/code}} 108 - 109 -\\ 110 - 111 111 DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00/CH00.TD or CH00.DAQ.TD{{/code}} 112 -here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is act ivated the {{code language="none"}}CH00.DAQ.TD{{/code}} contains only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is preferable to use ...105 +here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is actvated the {{code language="none"}}CH00.DAQ.TD{{/code}} contins only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is preferable to use ... 113 113 DAQ channel: {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00{{/code}} 114 114 115 115 in addition there are also additional parameters saved like: ... ... @@ -125,8 +125,7 @@ 125 125 * **we can offer [[ Phillips scientific Model 6954>>attach:6954ds.pdf]] amplifiers** to either amplify small signals or to decouple setups which may deliver voltage peaks fro the ADCs. 126 126 * The available ADCs 5x, 10x, 20 x 50x and 100x 127 127 * The ADCs can be borrowed from Markus Braune 128 -* The Amplifiers fit perfectly to the dynamic range of the GHz ADCs - here a [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]] 129 -* There are also [[BiasTs>>attach:ZX85-12G-S+.pdf]] available ([[link to internal page>>doc:FLASH.Bias T]]) 121 +* The Amplifiers fot perfectly to the dynamic range of the GHz ADCs - here a [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]] 130 130 131 131 \\ 132 132