Changes for page MTCA ADCs

Last modified by sndueste on 2024/07/08 09:50

From version 18.1
edited by sendels
on 2021/02/10 15:08
Change comment: There is no comment for this version
To version 15.1
edited by sndueste
on 2020/01/07 14:37
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.sendels
1 +XWiki.sndueste
Content
... ... @@ -109,7 +109,7 @@
109 109  \\
110 110  
111 111  DOOCS prop : {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00/CH00.TD  or CH00.DAQ.TD{{/code}}
112 -here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is activated the {{code language="none"}}CH00.DAQ.TD{{/code}} contains only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is preferable to use ...
112 +here the {{code language="none"}}CH00.TD{{/code}} is the full ADC trace as it is sampled ( typically several 100.000 samples per pulse train) while the {{code language="none"}}CH00.DAQ.TD{{/code}} trace only has the number of samples which are sent to the DAQ OR if //grouping// is actvated the {{code language="none"}}CH00.DAQ.TD{{/code}} contins only the grouped spectra. To read the ADC trace with an online analysis program the {{code language="none"}}CH00.DAQ.TD{{/code}} is preferable to use ...
113 113  DAQ channel: {{code language="none"}}FLASH.FEL/ADC.ADQ.PG/EXP1.CH00{{/code}}
114 114  
115 115  in addition there are also additional parameters saved like:
... ... @@ -125,8 +125,7 @@
125 125  * **we can offer [[ Phillips scientific Model 6954>>attach:6954ds.pdf]] amplifiers** to either amplify small signals or to decouple setups which may deliver voltage peaks fro the ADCs.
126 126  * The available ADCs 5x, 10x, 20 x 50x and 100x
127 127  * The ADCs can be borrowed from Markus Braune
128 -* The Amplifiers fit perfectly to the dynamic range of the GHz ADCs - here a  [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]]
129 -* There are also [[BiasTs>>attach:ZX85-12G-S+.pdf]] available ([[link to internal page>>doc:FLASH.Bias T]])
128 +* The Amplifiers fot perfectly to the dynamic range of the GHz ADCs - here a  [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]]
130 130  
131 131  \\
132 132  
... ... @@ -145,7 +145,7 @@
145 145  
146 146  Here is a trace of the first signal, a 1 MHz trigger connected from the x2timer board in the same MTCA:
147 147  
148 -[[image:attach:adc_mhz.jpg||height="400"]]
147 +[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/adc_mhz.jpg~|~|alt="adc_mhz.jpg" width="550" height="500"~]~]>>attach:adc_mhz.jpg]]
149 149  
150 150  \\
151 151  
... ... @@ -161,10 +161,8 @@
161 161  
162 162  \\
163 163  
164 - [[image:attach:image2019-11-18_17-9-7.png||height="400"]]
163 +[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/pulse_energy_server.jpg~|~|alt="pulse_energy_server.jpg" height="400"~]~]>>attach:pulse_energy_server.jpg]] [[image:attach:image2019-11-18_17-9-7.png||height="400"]]
165 165  
166 -[[image:attach:pulse_energy_server.jpg||height="400"]]
167 -
168 168  \\
169 169  
170 170   jddd  server panel  Definition of the parameters