Changes for page MTCA ADCs
Last modified by sndueste on 2024/07/08 09:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.s endels1 +XWiki.sndueste - Content
-
... ... @@ -1,43 +1,30 @@ 1 - === General info ===1 +Content: 2 2 3 -\\ 4 4 5 -* [[ADQ412 server description~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/FLASHWiki/Wiki.jsp?page=SPdevicesDMA%20ADQ||shape="rect"]] 6 -* [[more ADC server descriptions~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/DOOCSWiki/Wiki.jsp#section-C_2B_2B+Server+Interface-D_ADCscope?page=C%2B%2B%20Server%20Interface||shape="rect"]] 7 -* [[Description of the DAQ properties related to the ADCs~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/DOOCSWiki/Wiki.jsp#section-C_2B_2B+Server+Interface-DaqfedConfiguration.?page=C%2B%2B%20Server%20Interface||shape="rect"]] 8 -* [[ a collection of usefull things related to the OPIS ADCs>>doc:FLASHUSER.OPIS ADC related things]] 9 9 10 - \\5 +{{toc/}} 11 11 12 - === Our cards ===7 +---- 13 13 14 - \\9 += Our ADC cards = 15 15 16 -== ==SP-Devices ADQ412AC ====11 +== GHz ADCs: SP-Devices ADQ412AC == 17 17 18 18 We have ADQ412AC-4G-MTCA digitizer cards for the experiment crates (Exp1, Exp2 and FL2Exp1): 19 -[[ADQ412_datasheet.pdf>> url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/10-0494_C_ADQ412_datasheet.pdf||shape="rect"]] ( [[new version>>url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/10-0494-adq412_datasheet.pdf||shape="rect"]], [[sampling rates table>>url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/Clocking_AppNote.pdf||shape="rect"]])20 -The cards are connected via Patch panels to the Experimental endstations .14 +[[ADQ412_datasheet.pdf>>attach:10-0494_C_ADQ412_datasheet.pdf]] ( [[new version>>attach:10-0494-adq412_datasheet.pdf]], [[sampling rates table>>attach:Clocking_AppNote.pdf]]) 15 +The cards are connected via Patch panels to the Experimental endstations and can be operated with a jddd panel: 21 21 22 - \\17 +[[image:attach:image2019-10-21_15-21-23.png||width="800"]] 23 23 24 -* **NOTE: between ADC and Patch panel we have installed an [[EMP protector>>url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/EMP_protector.pdf||shape="rect"]] and an additional 1dB attenuator** 25 -* for the influence of the Patch cable and the EMP protector see also [[this logbook entry~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://ttfinfo.desy.de/ExpHallelog/show.jsp?dir=/2016/27/08.07&pos=2016-07-08T17:41:07||shape="rect"]] 26 -* we can offer amplifiers to either amplify small signals or to decouple setups which may deliver voltage peaks fro the ADCs. The available ADCs are: 27 -** 20 dB, 1 GHz, 50 Ohm, ( [[Minicircuits ZFL-1000LN+>>url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/ZFL-1000LN.pdf||shape="rect"]]) 28 -** 10 dB, 1.8 GHz, 50 Ohm, ( [[Becker und Hickl, ACA-1-10-I>>url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/ACA-amilifier.pdf||shape="rect"]]) 29 - 30 30 \\ 31 31 32 32 \\ 33 33 34 -* [[Hereisaetailedevaluation>>url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/Output_behaviour_of_Mini-Circuits_Amplifier.pdf||shape="rect"]]ofthe 2amplifiers , their linearityandinfluence onthe signalbroadeningfor differentinputsignals*35 -* Andthetestof the[[PhilipsscientificModel6954>>url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/Model_6954_Amplifier_Report.pdf||shape="rect"]]23 +* **NOTE: between ADC and Patch panel we have installed an [[EMP protector>>attach:EMP_protector.pdf]] and an additional 1dB attenuator** 24 +* for the influence of the Patch cable and the EMP protector see also [[this logbook entry~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:http://ttfinfo.desy.de/ExpHallelog/show.jsp?dir=/2016/27/08.07&pos=2016-07-08T17:41:07||shape="rect"]] 36 36 37 37 \\ 38 38 39 -\\ 40 - 41 41 (% class="wrapped" %) 42 42 |((( 43 43 Impedance AC ... ... @@ -61,7 +61,7 @@ 61 61 |((( 62 62 Sampling rate 63 63 )))|((( 64 -2 51 +2 * 65 65 )))|((( 66 66 GSPS 67 67 ))) ... ... @@ -79,7 +79,7 @@ 79 79 |((( 80 80 Sampling rate 81 81 )))|((( 82 -4 69 +4 * 83 83 )))|((( 84 84 GSPS 85 85 ))) ... ... @@ -91,6 +91,8 @@ 91 91 GHz 92 92 ))) 93 93 81 + ~* note that the sample rate is NOT locked to the FLASH repetition rate ! Thus there is a not integer number of samples between FLASH pulses. The sample rate also differs slightly from ADC card to ADC card. The rough spacing is **1993.846** samples between 2 pulses at 1 MHz for details ask the local contact. 82 + 94 94 \\ 95 95 96 96 ===== ADC and DOOCS / DAQ ===== ... ... @@ -124,8 +124,17 @@ 124 124 125 125 \\ 126 126 127 -== ==StruckSIS8300-L2D ====116 +== Amplifiers for the GHZ ADCs == 128 128 118 +* **we can offer [[ Phillips scientific Model 6954>>attach:6954ds.pdf]] amplifiers** to either amplify small signals or to decouple setups which may deliver voltage peaks fro the ADCs. 119 +* The available ADCs 5x, 10x, 20 x 50x and 100x 120 +* The ADCs can be borrowed from Markus Braune 121 +* The Amplifiers fot perfectly to the dynamic range of the GHz ADCs - here a [[ test of the Phillips scientific amplifier>>attach:Model_6954_Amplifier_Report.pdf]] 122 + 123 +\\ 124 + 125 +== 108 MHz ADCs: Struck SIS8300-L2D == 126 + 129 129 There is one in each of the MTCAs in the hall: MTCA-EXP1 at PG/BL1, the other at BL2 and BL3. 130 130 131 131 They are 16 bit, 10 channel, 125 MS/s ADCs. ... ... @@ -132,27 +132,50 @@ 132 132 133 133 \\ 134 134 135 -* [[User Manual SIS8300-L2 ADC ACM>> url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/sis8300l2-m-x009-1-v101.pdf||shape="rect"]]136 -* [[User Manual SIS8900 RTM>> url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/sis8900-m-1-1-v104.pdf||shape="rect"]]133 +* [[User Manual SIS8300-L2 ADC ACM>>attach:sis8300l2-m-x009-1-v101.pdf]] 134 +* [[User Manual SIS8900 RTM>>attach:sis8900-m-1-1-v104.pdf]] 137 137 138 138 50 Ohm input impedance, -1 V,...,+1 V default input range, analog signals can be routed to AC and DC input stage. The coupling is DC via op-amp (switching to AC transformer involves resoldering of SMD solder bridges). 139 139 140 140 Here is a trace of the first signal, a 1 MHz trigger connected from the x2timer board in the same MTCA: 141 141 142 -[[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/adc_mhz.jpg||alt="adc_mhz.jpg" width="550" height="500"]] 140 +[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/adc_mhz.jpg~|~|alt="adc_mhz.jpg" width="550" height="500"~]~]>>attach:adc_mhz.jpg]] 143 143 144 144 \\ 145 145 146 -== ==Using the Struck SIS8300-L2D to detect only integrated values of pulses ====144 +== Pulse energy server: Using the Struck SIS8300-L2D to detect only integrated values of pulses == 147 147 148 -FS-LA (Falko Peters) programmed a pulse detection server that automatically detects peaks in the sign el and integrates the samples around the peak.<\br> things to set:146 +FS-LA (Falko Peters) programmed a pulse detection server that automatically detects peaks in the signal and integrates the samples around the peak. 149 149 150 -* Peak height: from what signal on (incounts) is the signal to be counted as peak 148 +Things to set: 149 + 150 +* Min peak height: threshold fro which on some signal is considered to be a peak. The actual peak is then determined as the maximum of the counts after the threshold 151 151 * pre and post peak integration time: how much ns to be integrated before and after the peak sample that are taken into account for the peak 152 152 * pre and post peak noise time: before and after the samples that are taken for the actual signal these samples are used as background ( they also can be used to define the "deadtime" of the detector before it searches for new peaks. 153 153 154 - [[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/pulse_energy_server.jpg||alt="pulse_energy_server.jpg" width="400" height="300"]]154 +\\ 155 155 156 +[[~[~[image:url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/pulse_energy_server.jpg~|~|alt="pulse_energy_server.jpg" height="400"~]~]>>attach:pulse_energy_server.jpg]] [[image:attach:image2019-11-18_17-9-7.png||height="400"]] 157 + 156 156 \\ 157 157 158 -* [[Model_6954_Amplifier_Report.pdf>>url:http://hasfweb.desy.de/pub/Setup/MtcaAdc/Model_6954_Amplifier_Report.pdf||shape="rect"]]: Model_6954_Amplifier_Report.pdf 160 + jddd server panel Definition of the parameters 161 + 162 +\\ 163 + 164 +\\ 165 + 166 +\\ 167 + 168 += Detailed stuff = 169 + 170 +* [[ADQ412 server description~[~[image:url:http://hasfweb.desy.de/pub/TWiki/TWikiDocGraphics/external-link.gif~|~|width="13" height="12"~]~]>>url:https://ttfinfo.desy.de/FLASHWiki/Wiki.jsp?page=SPdevicesDMA%20ADQ||shape="rect"]] 171 +* [[ a collection of usefull things related to the OPIS ADCs>>doc:FLASH.OPIS ADC related things]] 172 + 173 +\\ 174 + 175 +\\ 176 + 177 +\\ 178 + 179 +\\